litefut2007 Electricity Level 2, Section 11

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/17

encourage image

There's no tags or description

Looks like no tags are added yet.

18 Terms

1
New cards

A motor overload relay consists of a current-sensing unit and mechanism activated by the sensing unit that

opens the motor circuit

2
New cards

If low-voltage and high-voltage cables must be placed in parallel runs, they should be separated by at least 6" in order to protect the low-voltage conductors from

noise

3
New cards

On magnetic contactors, which contacts are said to be normally open (NO)?

Those that are apart when the relay is de-energized

4
New cards

Lighting contactors are rated for

high inrush currents

5
New cards

Low-voltage remote control switching relays use

a split coil

6
New cards

Which of the following can provide motor overload protection but have the disadvantage of being nonrenewable?

Dual-element or time-delay fuses

7
New cards

An electromagnetic device that can be used to multiply the switching function of a pilot device is a

control relay

8
New cards

The two classifications of overload relays are thermal and

magnetic

9
New cards

When making connections to reverse the rotation of a motor,

L1 is connected to motor terminal T3, and L3 is connected to motor terminal T1

10
New cards

Mechanically held relays and contractors are often used because

they are quiter than electrically held devices

11
New cards

Which of the following has the advantage of being resistant to shock and vibration and is commonly used for the I/O track of a programmable controller?

Solid-state relay

12
New cards

The lubrication of a motor at prescribed intervals can be accomplished using a

timing relay

13
New cards

If contactor action is dependent on current flow, the contactor is described as

electrically held

14
New cards

Melting alloy and metallic overload relays are designed to

react to changes in the motor load current

15
New cards

Solid-state relays normally have control voltages of

3V to 32V

16
New cards

Which of the following is a probable cause of relay-controlled equipment failing to start when the contactor is closed?

one contact not closing

17
New cards

The panel for a low-voltage lighting control system enclosure should be mounted

at eye level between two studs

18
New cards

Increasing the armature spring force in a relay will result in

Higher drop-out values