FRV RC32 Branches & Friction Loss

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/24

encourage image

There's no tags or description

Looks like no tags are added yet.

25 Terms

1
New cards

Friction Loss for 38mm Hose @ 500lpm

220kpa

2
New cards

Friction Loss for 50mm Hose @ 500lpm

75kpa

3
New cards

Friction Loss for 50mm Hose @ 750lpm

220kpa

4
New cards

Friction Loss for 65mm Hose @ 500lpm

25kpa

5
New cards

Friction Loss for 65mm Hose @ 750lpm

55kpa

6
New cards

Friction Loss for 65mm Hose @ 1000lpm

100kpa

7
New cards

Friction Loss for 90mm Hose @ 2000lpm

100kpa

8
New cards

Friction Loss Laws (acronym)

DRISL

9
New cards

DRISL: D

Diameter : Friction loss increases directly with the decrease in diameter

10
New cards

DRISL: R

Roughness : Friction loss increases with the roughness of the hose interior

11
New cards

DRISL: I

Independent : Friction loss is a function of flow, independent of pressure

12
New cards

DRISL: S

Square : Friction loss increases directly as the square (^2) of the flow rate

13
New cards

DRISL: L

Length : Friction loss increases directly with the length of the hose.

14
New cards

Operating Pressure: Black Branch

700kpa - standard 400kpa - low

15
New cards

Operating Pressure: Blue Branch

500kpa

16
New cards

Operating Pressure: Purple Branch

300kpa

17
New cards

Operating Pressure: Ground Monitor

700kpa - standard 400kpa - low 1200kpa - max

18
New cards

Flow Rate: Black Branch

260-750lpm - auto 500lpm - 38mm hose 750lpm - 50mm hose

19
New cards

Flow Rate: Blue Branch

100lpm 250lpm 500lpm Selectable

20
New cards

Flow Rate: Purple Branch

450lpm Fixed Flow

21
New cards

Flow Rate: Ground Monitor

2000lpm

22
New cards

Ground Monitor Safety

  1. Legs must be fully extended 2. Max 1200 kPa operating pressure 3. Must be crewed at all times 4. Tie off where possible
23
New cards

Functions of the Ground Monitor

  1. Has a latch on bail to open 2. Has a safety shutoff 3. If slope greater than 10° slope – safety shut off won’t work 4. Jet Reaction – nozzle facing up is safest
24
New cards

PDP

Pump Delivery Pressure

25
New cards