MOD 5: Tower Structures

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/33

encourage image

There's no tags or description

Looks like no tags are added yet.

34 Terms

1
New cards

HIGH-RISE BUILDING

is generally defined as one that is taller than the maximum height which people are willing to walk up. It thus requires mechanical vertical transportation.

2
New cards

LOW-RISE

from 1 - 5 storeys i.e. 4.0 m to 16.0 m, inclusive of an average 1.0 m provision for parapet wall or roof apex; excludes maximum allowance for a 6.0 m tall antenna/ steel tower on top of the structure (only where allowed by the Civil Aviation Authority of the Ph/ CAAP);

3
New cards

MEDIUM-RISE

(from 6 - 15 storeys i.e. 19.0 m to 46.0 m, inclusive of an average 1.0 m provision for parapet wall or roof apex; excludes CAAP);

4
New cards

triskaidekaphobia

Omitting a thirteenth floor include _____ and to prevent problems that may arise with superstitious tenants, occupants, or customers. In 2002, based on an internal review of records, Dilip Rangnekar of Otis Elevators estimated that 85% of the buildings with Otis brand elevators did not have a floor named the 13th floor.

5
New cards

thirteenth floor

s a designation of a level of a multi level building that is often omitted in countries where the number 13 is considered unlucky.

6
New cards

fourth, fourteenth, twenty-fourth

Similarly, new buildings in some parts of China avoid the _____, ____, ____ etc. floors, as the word "four" (Hanzi: 四) sounds like "death" (死– pronounced "sì" and "sǐ", respectively) in Mandarin

7
New cards

HIGH-RISE

(from 16 - 60 storeys i.e. 49.0 m to 181.0 m, inclusive of an average 1.0 m provision for parapet wall or roof apex; excludes CAAP); and

8
New cards

VERY TALL BUILDING

(taller than 60 storeys i.e. taller than 181.0 m, inclusive of an average 1.0 m provision for parapet wall or roof apex; of the Ph/ CAAP).

9
New cards

The Functional Period

1880-1900 Opened in 1885, Jenney’s Home Insurance Building in Chicago further advanced the possibilities for iron construction. The building featured a hybrid construction of masonry cladding, iron beams and cast-iron connections to reinforce the internal structure, which resembled a grid-like skeleton. This method of lightening the load of the building’s walls made the original 10-story design of the Home Insurance Building both innovative and influential

10
New cards

The Eclectic Period

1900-1920 Daniel Hudson Burnham used the footprint of the site to generate the base of the building, and drew from classical architecture by making it resemble a column of antiquity, becoming more slender as it moves from the base up the shaft to the capital. The building is built around a skeleton of steel, fronted with limestone and terra cotta - inspired by the French and Italian Renaissance with a Beaux Arts styling that was popular at the time as a result of the 1893 World’s Columbian Exposition. At its narrow ‘prow’ end the building measures only 1.8m across. Viewed from above, it describes an acute angle of roughly 25-degrees

11
New cards

The Art Deco Period

1920-1940 The Chrysler Building is often regarded as a masterpiece of Art Deco architecture. It was created during a time when people were scrambling to make New York City the home to the tallest building in the world. The design went through quite a few different stages on its way to approval. In the end, Walter P. Chrysler and Van Alen worked together to create the classic look of the building. The building is held together by nearly 400,000 rivets and 3,826,000 bricks. The bricks were all manually laid and only comprise the non-load bearing walls of the building. The building has over 30 elevators connecting all 77 floors. It has a floor space of nearly 1.2 million square feet.

12
New cards

The International Style

1950-1970 The Seagram Building, with its use of modern materials and setback from the city grid, became a prototype for future office buildings designed by Mies as well as a model for many buildings erected in its surroundings. This building, fifty years after its completion, is still admired by many visitors everyday and sets an example of an International style skyscraper amidst the New York skyline

13
New cards

The Supertall Period

JOHN HANCOCK CENTER Construction on the tower began in 1965. Due to the high winds in Chicago, one of the main factors that had to be taken into consideration was using a secure structure for the building that would minimize movement on windy days. The structure consists of a tubular system that strengthens the building against wind and earthquakes. The famous cross-bracing on the exterior provides security against horizontal movement while opening up the interior of the building with more uninterrupted floor space. Although the X-bracing is massive and slightly blocks views from the interior, it is the Hancock Building's signature exterior feature and is structurally soundl Style –

14
New cards

The Social Skyscraper

1970-1980 Skyscrapers could no longer exist as isolated towers, each one cut off from the street and community of which it was part. The design that emerged was the forerunners of the postmodernism and Romantic Modern skyscraper of the late 20th century

15
New cards

The Postmodern Period

1980 Postmodernism, a reaction to the Modern Movement or Int’l Style, incorporated color, sculptured form and decoration. But the choice of exact style was wide open, and s type of modern eclectic approach emerged. This style is no longer confined to North America, with many of today’s skyscraper being built in Europe and the Far East. At present, high-rise structure is led by Philip Johnson, William Pedersen, Cesar Pelli, and Norman Foster

16
New cards
  1. Life Safety

  2. Utilities

  3. Maintenance

  4. Building Management System


PRIMODIAL CONSIDERATION FOR TOWER DESIGN

17
New cards

Escalator

is a moving staircase which carries people between floors of a building or structure

18
New cards

passenger elevator

is any elevator intended for the transport of people through a building. These elevators can vary drastically in terms of size, speed and interior options depending on the use of the elevator

19
New cards

Service elevators

are actually regular passenger elevators that have been outfitted with utility cabs and floors, and are usually in an “employees only” area of a commercial building. The most common example would be the service elevator used by housekeeping in hotels

20
New cards

Exit routes

must remain unobstructed. Fire exit doors must never be blocked, even temporarily. Exit routes should never be blocked by materials, equipment, or locked doors, or have dead-end corridors.

21
New cards

Linen chute

A passage in the form of a tunnel for sending soiled linen from the floor pantries of all floors to a central place near the laundry, from where it can be collected by the laundry staff.

22
New cards

Refuge area

is a separate space in high-rise buildings, where residents can take shelter in case of fire or other emergencies.

23
New cards

Helipad

is a landing area or platform for helicopters and powered lift aircraft.

24
New cards

OFFICEC/OFFICE BUILDING

the use of the building or the place is for the conduct of business or profession

25
New cards

RESIDENTIAL/RESIDENTIAL BUILDING

use of the building or the place is for dwelling.

26
New cards

COMMERCIAL SPACE

use of the building or place is for the sale of merchandise, commodities or goods to customers for their consumption.

27
New cards

GROSS FLOOR AREA

the total floor space within the perimeter of the permanent external building walls occupied by office areas; residential areas; commercial areas; corridors, lobbies, vertical penetrations; machine rooms, pump rooms, electrical; utility rooms, storage and closets; covered balconies and terraces; and other interior features. This excludes covered areas used for parking and driveways; and uncovered areas for AC cooling towers, overhead water tanks, roof decks, etc.

28
New cards

FIREWALL

an interior or exterior wall having sufficiently high fire resistance

29
New cards

COURT

an open, uncovered, and unoccupied space partially or fully surrounded by walls or building

30
New cards

CHASE

a continuous recess built into a wall to receive pipes, ducts, etc

31
New cards

ROOF DECKS

the flat portion of a roof used as a terrace, etc

32
New cards

PENTHOUSE

a structure occupying usually less than half the roof area of a flat roofed building

33
New cards

LOBBY

a space at the entrance of a building, theater, elevator, etc

34
New cards

SETBACK

a minimum distance between a property line and a building or portion thereof, as required by the ordinance or a code