Are oxygenation and ventilation the same thing?
No
Oxygenation
getting O2 from the alveoli to the blood
assessed using SpO2/PaO2
supplemental O2 can improve oxygenation
Ventilation
moving air in and out of the lungs
removes CO2
assessed using PaCO2
The role of supplemental oxygen in terms of oxygenation and ventilation
Supplemental oxygen CAN improve oxygenation, but does NOT NECESSARILY correct inadequate ventilation
Oxygen Source
Where the oxygen comes from (ex. wall oxygen or portable cylinder)
Flow Rate
How quickly oxygen is flowing from the source
measured in liters per minute (L/min)
Interface
What delivers the oxygen to the patient (ex. nasal cannula or mask)
FiO2 →fraction of inspired oxygen
The concentration of oxygen in the gas the patient breathes in
as FiO2 increases, stability of the patient is lower
Flow rate is not the same as FiO2? Why?
Flow rate
how much gas is flowing
expressed in L/min
FiO2
the concentration of oxygen in the gas the patient inspires
expressed as a fraction or percent
*with many interfaces the patient breathes a mixture of: supplemental O2 and room air (therefore exact FiO2 may vary)
Lower FiO2
Lower oxygen flow (i.e. 2L/min)→more room air entrained
When does the delivered FiO2 get closer to the anticipated FiO2?
Higher oxygen flow (10L/min) →less room air entrained
Why is FiO2 variable?
The amount of room air mixed with the delivered oxygen depends on both the oxygen flow rate and the patient’s breathing pattern and inspiratory demands
What does the FiO2 actually mean for the patient?
higher FiO2 increases the oxygen available in the alveoli for gas exchange
a patient requiring 90% (0.9) FiO2 has a high supplemental oxygen requirement and may have significantly impaired oxygenation
higher FiO2 foes not necessarily mean better SpO2 or adequate ventilation
*FiO2 tells us the oxygen concentration being delivered not how well the patients lungs are transferring oxygen into the blood
Two patients have an SpO2 of 94% at rest, patient A receives 30% FiO2 and patient B receives 90% FiO2.
Are these patients equally stable?
What does this suggest about their oxygen reserve?
What are the implications for mobilization?
No, patient B requires substantially more oxygen to maintain the same SpO2
Patient B likely has less oxygen reserve despite the same SpO2
Patient B is at greater risk of desaturation as oxygen demands increase. Assess stability and clarify with the team before mobilizing
Wall oxygen
connected to an oxygen flowmeter
flow set in L/min
commonly 0.5 or 1L/min intervals, depending on the flow meter
Portable oxygen cylinder
used for mobility and patient transport
flow set at the regulator
often uses a dial with a fixed flow setting (i.e. 0.5, 1, 1.5, 2, 3, 4, 6, 8, 10, 15)
****check how much oxygen is remaining before leaving the bedside
PT mobility considerations
secure the cylinder in an appropriate holder (cart, wheelchair, or walker)
check oxygen supply is sufficient for the planned activity
plan equipment management: can one person safely assist the patient and manage the oxygen?
IMPORTANT: never carry or balance an unsecured oxygen cylinder on mobility equipment
For PTs, what are our concerns with the interfaces?
mobility
eating/talking
tubing management
equipment required
Variable FiO2
The amount of oxygen inhaled can vary with the patient’s breathing
Fixed/controlled FiO2
Designed to deliver a specified oxygen concentration
Nasal Cannula/Nasal Prongs
Flow: ~0.5-6L/min
FiO2: 24-44% (variable)
oxygen delivered through nasal prongs mixes with room air →exact FiO2 varies
comfortable; allows eating, talking, coughing, and mobility
PT perspective on nasal cannulas
mobility-friendly
extension tubing may be used with appropriate low-flow systems
watch for tubing kinks, disconnection and trip hazards
Higher-Flow Nasal Prongs
Flow:~6-15L/min
FiO2: 24-60% (variable)
larger-bore prongs/tubing delivers higher O2 flows
room air mixing →variable FiO2
humidification may be used to reduce airway drying and discomfort
How to recognize higher-flow nasal prongs
larger prongs and thicker tubing than standard nasal cannula
often green tubing (but colour varies by manufacturer)
PT perspective on higher-flow nasal prongs
allows eating, talking, and mobility
higher O2 requirement →assess stability and portable O2 supply
do NOT add extension tubing unless approved for the specific system; added resistance may limit flow
Simple Face Mask
Flow: ~5-10L/min
FiO2: 35-60% (variable)
covers nose and mouth; O2 mixes with room air
FiO2 depends on breathing pattern and mask fit
minimum flow ~5L/min to flush exhaled CO2 and reduce rebreathing
PT perspective on simple face mask
more restrictive than nasal cannula; interferes with eating, drinking, and talking
maintain mask position and manage tubing during mobility
OxyMask
Flow: ~1-15L/min
FiO2: ~24-90% (variable)
open mask design allows room air entry
delivers a wide range of O2 concentrations depending on flow and patient factors
often better tolerated than enclosed masks (less claustrophobic)
PT perspective on OxyMask
mobility possible; ensure correct mask position and tubing management
eating/drinking may require temporary removal or adjustment
Venturi Mask
Flow: device specific
FiO2:~24-60% (fixed/controlled)
It delivers fixed O2 by:
oxygen passes through a specially desinged adapter
the adapter draws in a controlled amount of room air to mix with the oxygen
each adapter setting produces a specific oxygen concentration (FiO2) when the prescribed flow is used
**unlike nasal prongs, the delivered FiO2 remains relatively constant despite changes in breathing pattern, provided total flow meets the patients inspiratory demands (they are breathing what is controlled, no room air)
PT perspective on venturi mask
allows mobilization with an appropriate portable oxygen supply
maintain the prescribed adapter setting and oxygen flow
DO NOT block air-entrainment ports or change oxygen flow arbitrarily
Heated High-Flow Nasal Cannula (HFNC)
Flow: up to ~60L/min
FiO2: 21-100% (controlled)
delivers heated, humidified gas at high flow rates
flow and FiO2 are set independently
high flow minimizes room-air mixing →delivered FiO2 closely matches the set FiO2
mouth breathing or high inspiratory demands may increase room-air mixing
common systems: AIRVO/Optiflow
PT perspective on heated high-flow nasal cannula (HFNC)
mobilization may be possible if clinically stable (typically only EOB and maybe not even then)
assess oxygen requirements (flow/FiO2) and SpO2 response
plan for equipment, tubing length, and oxygen supply
coordinate with RT and follow local procedures
Non-rebreather mask
Flow: ~10-15L/min
FiO2:~60-90% (variable)
reservoir bag: stores oxygen to deliver high concentrations during inspiration
one-way valves: limit room-air entry and prevent rebreathing of exhaled gas
so why is FiO2 variable?
depends on mask fit, oxygen flow rate and patient’s inspiratory demands
Important: reservoir bag must remain adequately inflated during inspiration
PT perspective on non-rebreather mask
high oxygen requirement → assess clinical stability before activity
determine whether oxygen needs are stable or increasing
prioritize positioning, respiratory care, ROM and bed mobility, as appropriate
more advanced mobilization requires careful assessment and monitoring
Oxygen is a medication:
It should have a reason, dose, and target
Before treating a patient receiving oxygen, know:
why are they receiving it?
what interface are they using?
what flow rate/ FiO2?
what is their prescribed SpO2 target?
is this their usual oxygen requirements?
has their oxygen requirement increased?
Important precautions for working with a patient receiving oxygen
oxygen supports combustion: no smoking or open flames
use oxygen to achieve the prescribed SpO2 target
excessive oxygen can be harmful
some patients require lower SpO2 targets
Can a PT adjust oxygen?
In Nova Scotia, YES, under specific conditions
PTs may titrate, with typical nasal cannulas, low-flow oxygen (0-6L/min) during treatment when:
there is a written physical prescription with a target SpO2/range
the PT has required knowledge and competence
changes are communicated and documented
employer policies/procedures are followed
What don’t PTs have authority to do
do NOT adjust high-flow oxygen
changing the oxygen delivery device
What should you do before mobilizing a patient who is using supplemental oxygen?
Check the oxygen prescription an oxygen equipment
Check the oxygen prescription
interface and flow rate/FiO2
prescribed SpO2 target
baseline versus current oxygen requirement
Check the oxygen equipment
correct connections and flow settings
adequate tubing length and safe positioning
portable oxygen available and sufficient for activity
equipment secured and manageable during mobility
Why is it important to monitor oxygen delivery during mobility?
A drop in SpO2 may reflect a problem with oxygen delivery, not necessarily deterioration in the patient’s respiratory condition
is SpO2 within the prescribed target during activity?
does the patient require more oxygen during activity than at rest?
has the mask or cannula become displaced?
is tubing kinked, disconnected or creating a trip hazard?
is the portable oxygen supply adequate?
Key PT considerations for each oxygen interface:
Nasal cannula→ manage tubing; extension tubing may be used
Higher-flow nasal prongs → avoid extension tubing; check humidification
Simple face mask: maintain >/= 5L/min to minimize CO2 rebreathing
OxyMask →maintain correct mask position
Venturi mask → keep entrainment ports clear; maintain prescribed settings
Non-rebreather → ensure reservoir bag remains inflated; assess stability
Heated HFNC → specialized equipment; coordinate mobility with RT
**know the interface, oxygen requirements and prescribed SpO2 target. Ensure safe oxygen delivery throughout mobility