Physics U3 (Rad Protection & Equipment)

0.0(0)
Studied by 1 person
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/36

encourage image

There's no tags or description

Looks like no tags are added yet.

37 Terms

1
New cards

exposure

number of ionizations in air

2
New cards

how is exposure measured?

Coulombs per kilogram (C/kg)

3
New cards

air kerma

energy of ionizations in air

4
New cards

how is air kerma measured?

gray (or joules/kg)

5
New cards

what is air kerma useful for?

measuring tube output, leakage radiation and scatter

6
New cards

absorbed dose

the amount of energy absorbed per unit mass

7
New cards

how is absorbed dose measured?

gray (or joules/kg)

8
New cards

what is absorbed dose useful for?

predicting short term radiation injuries

9
New cards

equivalent Dose (EqD)

takes into consideration the type of ionizing radiation that was absorbed

10
New cards

How is equivalent dose determined?

absorbed dose x Wr (weight factor)

11
New cards

what is equivalent Dose measured in?

sieverts

12
New cards

effective dose

takes into consideration the relative radiation sensitivities of different tissue types

13
New cards

what is effective dose used for?

to predict the risk of long term radiation induced injuries

14
New cards

what is effective dose measured in?

sieverts

15
New cards

whole body exposure limits

5 rem/yr (50 mSv)

16
New cards

who is personnel monitoring provided to?

workers who accumulate 1/10 of recommended dose limit

17
New cards

where should devices be worn?

collar, waist, or ring

18
New cards

dosimetry

measurement of ionizing radiation doses to personnel

19
New cards

what detector is used in OSL badges?

aluminium oxide

20
New cards

how is an OSL processed?

using laser light to cause luminescence

21
New cards

disadvantage of OSL

expensive

22
New cards

what detector is used in TLD badges?

lithium fluoride crystals

23
New cards

how are TLDs processed?

released stored energy when heated as visible light

24
New cards

disadvantage of TLDs

sensitive to heat

25
New cards

disadvantage of pocket dosimeters

poor accuracy, must be recharged

26
New cards

purpose of dosimetry report

provide personnel with regular feedback reguarding protection practices

27
New cards

primary barriers

protect against direct exposure to the primary beam

28
New cards

secondary barriers

scatter and leakage radiation

29
New cards

cardinal principles of radiation control

time, distance, shielding

30
New cards

beam limitation

1/2 inch of collimation, field size never larger than IR

31
New cards

how can we minimize dose w technique?

highest kVp, lowest mAs

32
New cards

filteration

removes low energy photons

33
New cards

where is a filter placed?

between tube and patient

34
New cards

where are grids placed?

between the patient and IR

35
New cards

what grid ratio should be used?

the lowest possible

36
New cards

when is the fetus most radiosensitive?

8-15 weeks of gestation

37
New cards

pregnancy dose limit

0.5 rem if declared