Controlling microorganisms - outcomes
The methods of microbial control (used outside of the host body) are designed to result in 4 possible outcomes:
1. Sterilization
2. Disinfection
3. Antisepsis (also called degermation)
4. Decontamination (also called sanitization)

Sterilization
A process that destroys or removes all viable microorganisms, including bacterial endospores & all viruses
Doesn’t include removal of prions
Only result that’s 100% removal
Disinfection
A process that destroys vegetative pathogens (anything other than spores or cysts) but not bacterial endospores
Antisepsis/degermation
A process that reduces the number of microbes on the human skin (so goal is not to destroy all of them)
Decontamination/sanitization
A process that mechanically removed microorganisms as well as other debris to reduce contamination to safe levels
Different than antisepsis b/c it mechanically removes (outside human body)
Considered clean, but not sterile
Relative resistance of different microbial types to microbial control agents
Prions = most resistant (made up of just proteins, not considered microbes)
Microorganisms:
1. Bacterial endospores
2. Mycobacterium (due to their acid-fast cell walls)
3. Protozoa (cysts & trophozoites)
4. Gram-negative bacteria
5. Fungi & fungal spores
6. Non-enveloped viruses (naked; only capsid layer)
7. Gram-positive bacteria
8. Enveloped viruses (alcohol easily damages envelope)

Sterilization & disinfection agent used in the processes…
Bactericide
Fungicide
Virucide
Sporicide
Germicide/microbicide
“cide” = kill
Bacteristatic vs. Bactericidal effect
A cidal agent does not necessarily result in sterilization → it just needs to have the intent to kill
Often applies high temps
A static agent means to stop the growth of microbes without killing them
Often applies low temps
Devices for microbial control
Critical medical devices
Semicritical devices
Noncritical devices
Critical medical devices
Expected to come into contact w/ sterile tissues
Must be sterilized before use
Semicritical devices
Come into control w/ mucosal membranes
Must receive high-level disinfection, preferably sterilized
Noncritical devices
Do not touch the patient or only touch intact skin
Require only low-level disinfection, unless they become contaminated w/ blood or body fluids
Factors that influence action of antimicrobial agents
1. Number of microbes
Higher load of contaminants take longer to destroy
Microbial death continues in logarithmic manner as time or concentration is increased → active cells tend to die more quickly than less metabolically active cells
2. Nature of microorganisms in the population
Target population is usually a mixture of bacteria, fungi, spores, & viruses w/ broad spectrum of resistance
3. Temp & pH of environment
4. Concentration (dose & intensity) of agent
UV radiation is most effective at 260 nm
Most disinfectants are more active at higher concentrations
**Alcohol is the only one that still works well at lower concentration → also can’t be 100% concentration**
5. Mode of action of agent
How does it kill or inhibit microorganism (cidal vs. static)
6. Presence of solvents, interfering organic matter, & inhibitors
Saliva, blood, & feces can inhibit actions of disinfectants & even heat
So it makes them harder to kill
Modes of action of antimicrobial agents
Antimicrobials have a range of cellular targets
Cellular targets of physical & chemical agents:
1. Cell wall
2. Cytoplasmic membrane
3. Cellular synthetic processes (DNA, RNA)
4. Proteins
(Same chemical can have multiple effects → hit different targets)

Mode of action of Surfactants on the Cytoplasmic Membrane
Alcohol-based hand sanitizers are a mainstay of disinfection of surfaces & antisepsis of hands during the Covid-19 pandemic
SARS-CoV-2 is an enveloped virus & its envelope is susceptible to both detergents & alcohol
Microbial control methods - summary chart

Methods of physical control - heat
High temps are microbicidal, lower temps are microbistatic
2 types of heat:
1. Moist heat
2. Dry heat
Moist heat
Penetrates microbial cell better → lower temps & shorter exposure times to achieve the same effectiveness as dry heat
Microbicidal effect is the coagulation & denaturation of proteins
Ex. hot water, boiling water, or steam b/w 60°C-135°C (applying pressure allows it to go above boiling, aka >100°C)
Dry heat
Dehydrates the cell, removing water necessary for metabolic reactions
Denatures proteins
At very high temps, oxidizes cells, burning them to ashes (w/ incinerator)
Ex. hot air or an open flame, which ranges from 160°C-several thousand °C
Comparison of time & temps to achieve sterilization w/ moist & dry heat