1/55
Looks like no tags are added yet.
The “control layers” in a wall:
Weather barrier (for bulk water)
Vapor retarder (controls water vapor)
Air barrier (helps prevent infiltration)
Weather barrier
keeps out bulk water
protects structure
keeps insulation from getting wet
helps reduce windwash
Vapor retarder
prevents warm, moist air from being able to condense within the wall cavity
Always on the WARM side of the wall
measured in permeance (perm)
Air barrier
prevents draft
helps to slow vapor movement by reducing stack effect
The “perfect wall”
cladding, control layers, structure
Airsealing
the process of making the building airtight
necessary to: control heat flow (through infiltration), control water vapor (prevents condensation)
Stack effect
phenomenon of a strong air draft moving from ground level to the roof level of a building. affected by building height, configuration, and temperature differences between inside and outside air
Blower door test and what it measures
measures infiltration
Ventilation
letting in fresh air
usually achieved with an Energy Recovery Ventilator or Heat Recovery Ventilator
ERV and HRV
ERV (Energy Recovery Ventilator): able to preserve latent heat energy present in water vapor
HRV (Heat Recovery Ventilator): a very energy-efficient system that pulls the state air form outside your home
Permeance
measure of a materials resistance to water-vapor transmission, expressed in perms
Diffusion vs. Air leakage
diffusion: the process of moisture passing through breathable building material, like drywall and insulation. vapor barriers prevent that from happening.
Insulation
most work by preventing air movement, resulting in thermal statis
layers of trapped air slow movement of heat
the more layers the better insulator
R-value
change in degrees Fahrenheit
per British thermal unit
per hour
for one square foot of material
U-value
measures thermal conductivity
low U-value= better insulator
high U-value= poor insulator
inverse of R-value: U=1/R
IR camera (to see radiant surface temps)
Typical Insulation materials (and their approximate R-values!)
Fiberglass- 2.2 to 2.7 per inch
Mineral wool- 3.2 to 3.8 per inch
Cellulose- 3.2 to 3.8 per inch
Expanded polystyrene (EPS)- 3.85 per inch
Extruded polystyrene (XPS)- 4.7 per inch
Polyisocyanurate- 6.0 per inch
Polyurethane spray foam- 3.4 to 6.7 per inch
Fiberglass
made of plastic reinforced by tiny glass fibers
Mineral wool
material consisting of extremely fine fibers that have been spun together
Expanded polystyrene (EPS)
a closed cell foam that has been around since the 1950’s
98% trapped air and only 2% plastic, making it an efficient insulator with a small amount of raw material
Extruded polystyrene (XPS)
manufactured through an extrusion process. involves melting together the plastic resin and other ingredients.
Polyisocyanurate
thermoset plastic typically produced as a foam
Polyurethane spray foam
a spray-applied plastic that is widely used to insulate buildings and seal cracks and gaps, making the building more energy-efficient and comfortable
Aerogel
synthetic low-density materials formed by removing the liquid from a gel under special drying conditions
Vacuum insulated panels (VIP’s)
a form pf thermal insulation consisting of gas-tight enclosure surrounding a rigid core, from which air has been evacuated
Additive method of assembly R-value calculation
calculate R-values of thickness of each material in the assembly and add them up
Cylinder glass
glass blown in the shape of a cylinder then split and flattened into a sheet
Float glass
a sheet of glass made by floating molten glass on a bed of molten metal
Reflective coatings
Wet glazing
liquid sealant that dries
Dry glazing
gasketed
Extrusion
long pieces with section profiles designed to receive glazing units
conductive (metal…)
Mullion
a slender vertical division between adjacent lights or subdivisions in a window or between windows in a group
Thermal break
used to “break” the path of heat flow through the metal
Stick system
all pieces arrive individually
Unit system
prefabbed units are attached to mounting anchors
Unit-and-mullion system
prefabbed units are mounted to mullions which are mounted to anchors
Panel system
prefabbed units are attached to mounting anchors
Column cover and spandrel system
column cover is attached to column, spandrel panel attached to column covers, then glazing supported by spandrel panel
Storefront vs. Curtainwall:
Storefront
Allows drainage out of mullion
Supported by building structure
Curtainwall
Sealed to keep water out of mullions (higher pressure at higher altitudes)
Attached to building structure, but self-supporting
Storefront
Allows drainage out of mullion
Supported by building structure
Curtain wall
Sealed to keep water out of mullions (higher pressure at higher altitudes)
Attached to building structure, but self-supporting
Pressure equalized rainscreen
has a closed joint via infill strips that act as air dams in both vertical and horizontal joints. the air pressure equalizes and keeps rain and snow from getting driven into the wall cavity, significantly reducing the amount of moisture that goes into our system
Pressure equalization chamber
prevents pressure-driven moisture infiltration by naturally regulating the pressure within the wall cavity
Rainscreen cladding
made with a bearing wall, an insulation layer and a cladding material that is fixed to the building using a supporting structure
creates an air cavity is created between the load bearing wall and the cladding material, allowing continuous ventilation
Point-supported glass systems
creates flexible and modular wall that can be used in large spaces to create smaller areas for specific purposes from conference rooms to showrooms
metal fittings are used to join corners and edges
Brick veneer
Stone veneer
Precast veneer
Safing
block movement of fire at gaps between structure and curtainwall each floor
Sealant and backer rod
backer rod provides interior surface for sealant to meet.
Siding panels
Wall shingles
Lap siding
Fiber cement
Engineered wood siding