The “control layers” in a wall:

Weather barrier (for bulk water)

Vapor retarder (controls water vapor)

Air barrier (helps prevent infiltration)

2
New cards

Weather barrier

keeps out bulk water

protects structure

keeps insulation from getting wet

helps reduce windwash

3
New cards

Vapor retarder

prevents warm, moist air from being able to condense within the wall cavity

Always on the WARM side of the wall

measured in permeance (perm)

4
New cards

Air barrier

prevents draft

helps to slow vapor movement by reducing stack effect

5
New cards

The “perfect wall”

cladding, control layers, structure

6
New cards

Airsealing

the process of making the building airtight

necessary to: control heat flow (through infiltration), control water vapor (prevents condensation)

7
New cards

Stack effect

phenomenon of a strong air draft moving from ground level to the roof level of a building. affected by building height, configuration, and temperature differences between inside and outside air

8
New cards

Blower door test and what it measures

measures infiltration

9
New cards

Ventilation

letting in fresh air

usually achieved with an Energy Recovery Ventilator or Heat Recovery Ventilator

10
New cards

ERV and HRV

ERV (Energy Recovery Ventilator): able to preserve latent heat energy present in water vapor

HRV (Heat Recovery Ventilator): a very energy-efficient system that pulls the state air form outside your home

11
New cards

Permeance

measure of a materials resistance to water-vapor transmission, expressed in perms

12
New cards

Diffusion vs. Air leakage

diffusion: the process of moisture passing through breathable building material, like drywall and insulation. vapor barriers prevent that from happening.

13
New cards

Insulation

most work by preventing air movement, resulting in thermal statis

layers of trapped air slow movement of heat

the more layers the better insulator

14
New cards

R-value

change in degrees Fahrenheit

per British thermal unit

per hour

for one square foot of material

15
New cards

U-value

measures thermal conductivity

low U-value= better insulator

high U-value= poor insulator

inverse of R-value: U=1/R

16
New cards

IR camera (to see radiant surface temps)

17
New cards

Typical Insulation materials (and their approximate R-values!)

Fiberglass- 2.2 to 2.7 per inch

Mineral wool- 3.2 to 3.8 per inch

Cellulose- 3.2 to 3.8 per inch

Expanded polystyrene (EPS)- 3.85 per inch

Extruded polystyrene (XPS)- 4.7 per inch

Polyisocyanurate- 6.0 per inch

Polyurethane spray foam- 3.4 to 6.7 per inch

18
New cards

Fiberglass

made of plastic reinforced by tiny glass fibers

19
New cards

Mineral wool

material consisting of extremely fine fibers that have been spun together

20
New cards

Expanded polystyrene (EPS)

a closed cell foam that has been around since the 1950’s

98% trapped air and only 2% plastic, making it an efficient insulator with a small amount of raw material

21
New cards

Extruded polystyrene (XPS)

manufactured through an extrusion process. involves melting together the plastic resin and other ingredients.

22
New cards

Polyisocyanurate

thermoset plastic typically produced as a foam

23
New cards

Polyurethane spray foam

a spray-applied plastic that is widely used to insulate buildings and seal cracks and gaps, making the building more energy-efficient and comfortable

24
New cards

Aerogel

synthetic low-density materials formed by removing the liquid from a gel under special drying conditions

25
New cards

Vacuum insulated panels (VIP’s)

a form pf thermal insulation consisting of gas-tight enclosure surrounding a rigid core, from which air has been evacuated

26
New cards

Additive method of assembly R-value calculation

calculate R-values of thickness of each material in the assembly and add them up

27
New cards

Cylinder glass

glass blown in the shape of a cylinder then split and flattened into a sheet

28
New cards

Float glass

a sheet of glass made by floating molten glass on a bed of molten metal

29
New cards

Reflective coatings

30
New cards

Wet glazing

liquid sealant that dries

31
New cards

Dry glazing

gasketed

32
New cards

Extrusion

long pieces with section profiles designed to receive glazing units

conductive (metal…)

33
New cards

Mullion

a slender vertical division between adjacent lights or subdivisions in a window or between windows in a group

34
New cards

Thermal break

used to “break” the path of heat flow through the metal

35
New cards

Stick system

all pieces arrive individually

36
New cards

Unit system

prefabbed units are attached to mounting anchors

37
New cards

Unit-and-mullion system

prefabbed units are mounted to mullions which are mounted to anchors

38
New cards

Panel system

prefabbed units are attached to mounting anchors

39
New cards

Column cover and spandrel system

column cover is attached to column, spandrel panel attached to column covers, then glazing supported by spandrel panel

40
New cards

Storefront vs. Curtainwall:

Storefront
    Allows drainage out of mullion

    Supported by building structure

Curtainwall

    Sealed to keep water out of mullions (higher pressure at higher altitudes)

    Attached to building structure, but self-supporting

41
New cards

Storefront

Allows drainage out of mullion

Supported by building structure

42
New cards

Curtain wall

Sealed to keep water out of mullions (higher pressure at higher altitudes)

Attached to building structure, but self-supporting

43
New cards

Pressure equalized rainscreen

has a closed joint via infill strips that act as air dams in both vertical and horizontal joints. the air pressure equalizes and keeps rain and snow from getting driven into the wall cavity, significantly reducing the amount of moisture that goes into our system

44
New cards

Pressure equalization chamber

prevents pressure-driven moisture infiltration by naturally regulating the pressure within the wall cavity

45
New cards

Rainscreen cladding

made with a bearing wall, an insulation layer and a cladding material that is fixed to the building using a supporting structure

creates an air cavity is created between the load bearing wall and the cladding material, allowing continuous ventilation

46
New cards

Point-supported glass systems

creates flexible and modular wall that can be used in large spaces to create smaller areas for specific purposes from conference rooms to showrooms

metal fittings are used to join corners and edges

47
New cards

Brick veneer

48
New cards

Stone veneer

49
New cards

Precast veneer

50
New cards

Safing

block movement of fire at gaps between structure and curtainwall each floor

51
New cards

Sealant and backer rod

backer rod provides interior surface for sealant to meet.

52
New cards

Siding panels

53
New cards

Wall shingles

54
New cards

Lap siding

55
New cards

Fiber cement

56
New cards

Engineered wood siding