RNPCP - CHAPTER 13 JOINTS AND CONNECTIONS

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/28

encourage image

There's no tags or description

Looks like no tags are added yet.

29 Terms

1
New cards

25.4mm - Minimum depth to be filled with molten pig lead.

2
New cards

3.2mm - Extension of the finished joint below the rim of the hub.

3
New cards

Schedule 80 - Minimum wall thickness of threaded plastic pipe.

4
New cards

19mm - Minimum thickness of exposed wiped surface on each side of a wiped joint, and at least as thick as the material being joined.

5
New cards

0.2% or 0.002 - Maximum lead content allowable for solders and fluxes in potable water piping.

6
New cards

Schedule 80 - Job-Fabricated female screws.

7
New cards

76mm to 102mm - Enlargement of closet bend from _____ shall be considered an obstruction.

8
New cards

Caulked joints - for bell-&-spigot Cast Iron Soil (CISP) & other similar joints shall be firmly packed with oakum or hemp & filled with pig lead to a depth of not less than 25.4mm.

9
New cards

Threaded joints - for Iron Pipe Size (IPS) pipe & fittings shall be standard taper pipe threads. Threaded Plastic Pipe shall be Sch.80 min. wall thickness.

10
New cards

Wiped joints - joints in lead pipe fittings or between lead pipe or fittings & brass or copper pipe, ferrules, solder nipples or traps shall be full-wiped lead joints. Wiped lead joints shall have an exposed surface on each side of a joint not less than 19mm & at least as thick as the material being joined.

11
New cards

Solder & Sweat joints - joints in copper tubing shall be made by the appropriate use of approved brass or copper fittings. Solders & fluxes with a lead content which exceeds 0.002 are prohibited in piping systems used to convey potable water.

12
New cards

Flared joints - for soft copper water tubing

13
New cards

Cement Mortar joints - except for repairs & connections to existing lines constructed with such joints such joints prohibited on new building sewers.

14
New cards

Burned Lead joints - shall be fused together to form a uniform weld at lest thick as the lead sheets being joined.

15
New cards

Asbestos Cement Sewer Pipe joints - shall be a sleeve coupling of the same composition as the pipe or of other approved materials, and sealed with neoprene rubber rings or joined by approved type compression coupling

16
New cards

Mechanical joints - shall be for Centrifugal Cast Iron water pipe.

17
New cards

Molded Rubber Coupling Joints - joined by means of molded neoprene rubber coupling joints. Neoprene rubber shall be used in soils subject to oil intrussion.

18
New cards

Elastomeric Gasketed & Rubber-ring Joints - shall conform to IAMPO (International Association of Plumbing & Mechanical Officials) Installation Standard. Neoprene gaskets are recommended for oil handling piping works.

19
New cards

Pressure-Lock Type Connection - a mechanical connection which depends on an internal retention device to prevent pipe or tubing separation. Connection is made by inserting the pipe or tubing inside the filling to a prescribed depth.

20
New cards

Shielded Coupling & Hubless Cast Iron Pipe joints - shall not be considered as slip joints.

21
New cards

Clay Sewer Pipes - shall be joined with neoprene gasket for hub & spigot joints

22
New cards

Screwed Pipe to Cast Iron Pipe - - shall be either caulked or threaded

23
New cards

Lead to Cast Iron, Wrought Iron to Steel - shall be by means of wiped joints to caulking ferrule, soldering nipple or bushing.

24
New cards

Copper Tubing to Screw Pipe Joints - shall be made by the use of brass adaptor fittings. Joints between copper tubing & the fittings shall be properly sweated or soldered or made with flared & screw ends adaptor fittings the connection between the treaded pipe & the fitting made with a standard pipe size screw joint.

25
New cards

Slip joints - may be used in fixture drains & traps.

26
New cards

Expansion joints - used in soil & waste stacks to provide necessary expansion & contraction joints of the pipes for high-rise buildings.

27
New cards

Graphite-impregnated Asbestos - Gasket Material shall be______, felt, or similar approved types.

28
New cards
29
New cards

Copper Water Tube

shall be joined by brass fittings properly soldered or brazed together.