Radiation Therapy/Nuc Med (quiz 6)

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/39

encourage image

There's no tags or description

Looks like no tags are added yet.

40 Terms

1
New cards

The nuclear stability of an element is principally determined by the

a. number of valence electrons

b. neutron to proton ratio

c. nucleon to electron ratio

d. atomic number

b

2
New cards

The radioactive elements Carbon-12, Carbon-13 and Carbon-14 are ____ to each other

a. isobars

b. isomers

c. isotopes

d. isotones

c

3
New cards

In order to achieve nuclear stability, a radionuclide may emit

a. beta particles

b. gamma photons

c. positrons

d. all of the above

d

4
New cards

The unit of radioactivity commonly used in nuclear medicine is the

a. Becquerel

b. Curie

c. Tesla

d. Coulomb

a

5
New cards

A milliCurie is

a. abbreviated as mCi

b. 3922 counts per second

c. 37 MBq

d. all of the above

d

6
New cards

The time it takes for a radioactive nucleus to decay to 1/2 its original activity level is termed its

a. half-value layer

b. half-life

c. inverse decay quotient

d. decay scheme

b

7
New cards

The physical half-life of technetium-99 is approximately

a. 110 minutes

b. 2 hours

c. 6 hours

d. 73 hours

c

8
New cards

The biological half-life of a radionuclide takes into account its

a. physical decay scheme

b. physical half-life

c. metabolism within the human body

d. effective half-life

c

9
New cards

All of the following are true of a radionuclide effective half-life EXCEPT

a. it takes into account the relationship between physical and biological half-lives

b. is is the product of the physical and biologic half-lives divided by the sum of the physical and biologic half-lives

c. it is always shorter than either the physical half-life or biologic half-life

d. it is of little importance as a consideration of radionuclides used for medical diagnosis

d

10
New cards

Technetium-99m is an idea isotope because of its

a. long half-life

b. alpha particle emissions

c. low energy range

d. none of the above

d

11
New cards

The isotope of choice for the measurement of myocardial perfusion is

a. Tc-99m

b. Ga-67

c. TI-201

d. F-18

c

12
New cards

Technetium-99m is regarded as the "ideal radionuclide" because of its

1. isomeric energy value of 190 KeV

2. ability to be produced by a generator in the radiopharmacy

3. gamma emissions

4. physical half-life of about 6 hours

5. availability and cost

6. minimal compton interactions based upon its energy level

7. being blocked by thick lead blocks

8. energy level useful for medical diagnosis

9. beta emissions

10. gamma emissions of 90 KeV

a. 1, 3, 4, 5, 7, and 8 only

b. 1, 2, 4, 6, 8, and 9 only

c. 2, 3, 4, 5, 7, and 8 only

d. 2, 3, 4, 5, 6, 8, and 10 only

c

13
New cards

Radiopharmacies located within a hospital

a. are commonly called "hot labs"

b. need not conduct quality control as they know what they are producing as an eluate

c. require daily quality control testing by a NRC rep

d. all of the above

a

14
New cards

Unused radionuclides must be disposed of

a. immediately after a patient injection

b. when the activity reaches background radiation level

c. after the hospital RSO inspects the unused portion

d. after one additional half-life

b

15
New cards

The radionuclide emission used for most all nuclear diagnostic studies is

a. x-rays

b. beta particles

c. gamma photons

d. alpha particles

c

16
New cards

The scintillation crystal in an Anger camera is

a. calcium tungstate

b. sodium iodide

c. sodium chloride-thallium activated

d. amorphous selenium

b

17
New cards

During a nuclear study, gamma emissions from the patient are intercepted by the gamma camera crystal. The energy of the gamma photons is

a. converted to very low energy light

b. ultimately converted to electrons that are amplified by photomultiplier tubes

c. both a and b

d. none of the above

c

18
New cards

The Anger logic circuit in the gamma camera system

a. ensures the final image data point matches its spatial orientation of origin

b. performs output analysis of the data fro the camera

c. has a 5% accuracy with the precision of data points

d. all of the above

d

19
New cards

The nuclear medicine acquisition matrix

a. uses smaller matrices for high count studies such as with the heart

b. is fixed regardless of the anatomy being studied due to the collimator geometry

c. produces higher resolution images than digital radiography

d. is always square due to the shape of the detector crystal

a

20
New cards

All of the following are methods of nuclear image acquisition EXCEPT

a. dynamic, gated imaging

b. SPECT

c. radiofluoroscopic

d. planar

c

21
New cards

Nuclear images acquired by the way of SPECT scanning

a. are taken in a non-rotational, planar fashion

b. use only a single head camera

c. produce a cross-sectional image of the anatomy

d. use the same protocols for all SPECT studies

c

22
New cards

Positron emission tomography (PET) scanning

a. requires sophisticated lead collimators

b. is more sensitive than non-PET imaging for the same radionuclide amount

c. produces images of less resolution than planar images

d. relies on the creation of a neutron annihilating an electron to create a pair of x-ray photons from the electron cloud

b

23
New cards

The nuclear medicine device used to determine the location and activity of a possible radionuclide spill is a/an

a. dose calibrator

b. uptake probe

c. Geiger-Mueller counter

d. well counter

c

24
New cards

All of the following are true of alpha and beta emissions EXCEPT

a. the produce ionizations

b. the are highly penetrating

c. the are unable to penetrate the outer layers of skin

d. they have a mass and a charge

b

25
New cards

All of the following are related EXCEPT

a. spare healthy tissues

b. preserve surrounding tissue function

c. eradicate the malignancy

d. prolong side effects as tissue recover

d

26
New cards

Radiotherapy treatment plans require

a. an informed consent

b. a psychological examination

c. an assessment by a physical therapist

d. the patient to take a leave of absence from work

a

27
New cards

The treatment planning process is typically completed

a. using a linear accelerator

b. using a Cobalt radiotherapy unit

c. using a simulator

d. using an MR simulator

c

28
New cards

Typical radiotherapy treatment sessions require the rotation of the therapy unit around the patient. The precision necessary to ensure rotational accuracy mandates that the theory unit

a. rotate using laser precision

b. rotate around the isocenter of the unit

c. be checked daily for rotational precision

d. all of the above

d

29
New cards

PET/CTs are considered

a. hybrid machines

b. essential to fusion imaging

c. integral to treatment planning and staging

d. all of the above

d

30
New cards

Each of the following are essential to the calculation of irradiated tissue volume EXCEPT

a. dimensional target volume (DTV)

b. clinical target volume (CTV)

c. planning target volume (PTV)

d. gross target volume (GTV)

a

31
New cards

The total tissue volume irradiated takes into account the

a. patient's body motions, such as respiration

b. the zone of tissue surrounding the malignant mass

c. size and dimension of the malignant mass

d. all of the above

d

32
New cards

Radiotherapy treatment plans

a. are carried out by radiotherapists

b. require the patient to suspend respiration for the duration of the treatment

c. require that laser lines are superficially and painlessly burned into the patient's skin

d. allow patients to readjust their position after a period of time

a

33
New cards

Image guided radiotherapy (IGRT)

a. permits the placement of internal radiotherapy sources

b. provides CT images of the therapy patient

c. allows the radiotherapist to take x-ray images of the patient

d. is considered an obsolete technology and being replaced by intensity modulated therapy

c

34
New cards

Imaging gives the radiation therapist and oncologist

a. a perspective of the shrinkage of the tumor as radiation is being administered

b. an opportunity to see if the patient's vital structures are being damaged during treatment sessions

c. the ability to compare the planned treatment field with the anatomy of the patient

d. the flexibility to adjust dosages during treatment sessions

c

35
New cards

When radiographic images are produced during portal imaging using megavoltages

a. high contrast images are produced due to the number of photoelectric interactions

b. pair production and compton interactions predominate

c. very low contrast images are produced

d. both b and c

d

36
New cards

Radiotherapy of the prostate is particularly difficult due to its

a. small size

b. anatomical position between the rectum and bladder

c. radio resistance to high energy x-rays

d. inability to be visualized using IGRT

b

37
New cards

IGRT is an important part of a successful radiotherapy program because of its

a. ability to create images

b. capability for gated treatment fields

c. technology for optical tracking of tumor location and size

d. all of the above

d

38
New cards

Linear accelerators are capable of

a. 360-degree rotation

b. x-ray and electron therapy

c. measuring dose rate in real time

d. all of the above

d

39
New cards

All of the following are components of a typical linear accelerator EXCEPT

a. gantry and collimator assembly

b. simulator

c. treatment couch

d. control console and modulator cabinet

b

40
New cards

Proton radiotherapy is particularly beneficial because of

a. protons depositing their total energy within the target tissue

b. the positive charge of protons

c. the minimal scatter radiation produced with protons

d. all of the above

d