Address the client by name and introduce yourself by name.
Turn on the water at the sink.
Wet hands and wrists thoroughly.
Apply soap.
Lather all surfaces of wrists, hands, and fingers with friction for at least 20 seconds; keep hands below elbows and fingertips pointing down.
Clean fingernails by rubbing fingertips against the opposite palm.
Rinse all surfaces, keeping hands below elbows and fingertips pointing down.
Dry all surfaces from fingertips toward wrists with clean paper towels; discard towels.
Turn off faucet with a clean paper towel and discard it, or use knee/foot controls.
Never touch the inside of the sink.
Never touch the inside of the sink.
Explain the procedure clearly.
Provide full 360-degree privacy as required in North Carolina.
Position the client lying on their back (supine).
Turn the stocking inside out at least to the heel.
Place the stocking over the toes, foot, and heel.
Pull the top of the stocking over the foot, heel, and leg.
Move the foot and leg gently; avoid force or overextension.
Check for no twists or wrinkles and correct heel/toe-opening placement.
Leave the signaling device within reach and bed in low position.
Wash hands.
Wash hands.
Explain the procedure clearly.
Provide full 360-degree privacy as required in North Carolina.
Ensure the client wears non-skid footwear.
Set the bed at a safe level.
Check and/or lock the bed wheels.
Assist the client to sit with feet flat on the floor.
Secure the transfer belt at the waist over clothing or gown.
Explain how the client can help and agree on a signal to stand.
Face the client safely and count to three or give the agreed signal.
On the signal, help the client stand using an upward grasp on both sides of the belt and stabilize the legs knee-to-knee or toe-to-toe.
Walk slightly behind and to one side for 10 feet while holding the belt.
Assist the client back to bed and remove the belt.
Leave the signaling device within reach and bed in low position.
Wash hands.
Wash hands.
Explain the procedure clearly.
Provide full 360-degree privacy as required in North Carolina.
Lower the head of the bed before placing the bedpan.
Put on clean gloves.
Place the bedpan correctly under the client's buttocks.
Remove gloves safely and wash hands.
Raise the head of the bed after positioning the client on the bedpan.
Place toilet tissue within reach.
Place a hand wipe within reach and instruct the client to clean their hands when finished.
Place the signaling device within reach and ask the client to signal when finished.
Put on clean gloves before removing the bedpan.
Lower the head of the bed before removing the bedpan.
Keep the client covered except when placing or removing the bedpan.
Empty and rinse the bedpan; pour rinse into the toilet.
Place the bedpan in the designated dirty supply area.
Remove gloves safely and wash hands.
Leave the signaling device within reach and bed in low position.
Leave the signaling device within reach and bed in low position.
Put on clean gloves before handling the denture.
Line the sink or partially fill it with water to protect the denture if dropped.
Rinse the denture under moderately warm running water.
Apply denture toothpaste to the toothbrush.
Brush all surfaces of the denture.
Rinse all surfaces of the denture under moderately warm running water.
Rinse the denture cup and lid.
Place denture in the cup with water/solution and put on the lid.
Rinse the toothbrush and place it in the designated container.
Maintain clean technique with the toothbrush and denture.
Remove/dispose of the sink liner or drain the sink appropriately.
Remove gloves safely and wash hands.
Remove gloves safely and wash hands.
Explain the procedure clearly.
Place fingertips on the thumb side of the wrist to locate the radial pulse.
Count beats for one full minute.
Leave the signaling device within reach.
Wash hands before recording.
Record the pulse rate within ±4 beats of the evaluator's reading.
Record the pulse rate within ±4 beats of the evaluator's reading.
Explain the procedure for testing.
Count respirations for one full minute.
Leave the signaling device within reach.
Wash hands before recording.
Record the respiration rate within ±2 breaths of the evaluator's reading.
Record the respiration rate within ±2 breaths of the evaluator's reading.
Pick up and unfold the gown.
Face the back opening and place arms through the sleeves.
Fasten the neck opening.
Secure the gown at the waist, covering the back of clothing as much as possible.
Put on gloves, overlapping the gown cuffs.
With one gloved hand, grasp the other glove at the palm and remove it.
Slide fingers of the ungloved hand under the remaining glove cuff at the wrist and remove it inside out.
Discard gloves without contaminating yourself.
Unfasten the gown at the waist and neck.
Remove the gown without touching its outside.
Hold the gown away from the body and floor, turn it inward, and keep it inside out.
Discard the gown without contaminating yourself.
Wash hands.
Wash hands.
Explain the procedure clearly.
Provide full 360-degree privacy as required in North Carolina.
Ask which shirt the client would like and use the shirt chosen.
Keep the client's chest covered to avoid overexposure.
Remove the gown from the unaffected left side first, then the affected right side.