1/55
Looks like no tags are added yet.
Spatial Resolution
The sharpness of structural edges or lines as recorded in the radiographic image
-how well we can see it/how crisp
Spatial Resolution determines...
accuracy of the anatomical structural lines
Resolution
the ability of the imaging system to produce separate images of closely spaced objects
Spatial Resolution is determined/calculated by...
the line pair test tool
Line pair
a line and a space
What is the greates enemy to spatial resolution?
Motion as it detroys it and causes blurring
Two types of motion
voluntary and involuntary
Voluntary motion
motion that can be consciously controlled by the patient's will (could happen if pt. doesn't listen to instructions)
Involuntary Motion
attributed to the physiological action of the systems of the body (peristalsis, heart beat - issue for CT)
-something we cannot control
Ways in which motion is controlled:
-Proper immobilization of the part of patient
-proper explanation to the patient
-reducing exposure time (high mA, low time)
-suspension of respiration
Any motion will cause...
unsharpness causing a decrease un spatial resolution because the part becomes blurred
Object Shape and Spatial Resolution
the shape of the structure can lead to unsharpness
-we cannot control this as most anatomical structures have rounded borders
Focal Spot Size only affects...
Spatial Resolution
Focal Spot
the precise point at which x-rays are produced
Line Focus Principle design gives...
a larger heating area while maintaining a smaller effective focal spot
Line Focus Principle
accomplished by angling the face of the anode 5-20 degrees from vertical, most common is 11 degrees
Effective Focal Spot Size
refers to the focal spot size as measured directly under the anode target, has less heat and will always be smaller
-area seen by pt. or the IR
Actual Focal Spot Size
the size of the area on the anode target that is exposed to electrons from the tube current, will always be larger and uses more heat
-measurable area
Most x-ray tubes are what kind of tubes?
Dual Focus Tubes w/ and small and large focal spot
Small Focal Spot
better spatial resolution/ sharper the image but more heatload on tube
Large Focal Spot
less spatial resolution/ more unsharpness but more heat dissapation to not crack anode
Umbra
term used to decribe the image proper
Penumbra
term used to describe the outer edge (hazy edge), the amount of unsharpness
-area after lines intersect
The penumbra is more pronounced at... (SID)
shorter SIDs, than long, telling us that longer SID's will give better spatial resolution and a sharper image
The penumbra is more pronounced at... (OID)
larger OIDs, than a smaller one, telling us that the smaller OID the better the spatial resolution anf a sharper image
Formula to calculate the geometric unsharpness (blur or penumbra)
P= FSS x OID/ SOD
SOD is calculated by...
SID - OID
Monitor Resolution
digital equipment has less capability for spatial resolution that the older film technology because analog film is physically capable of drawing a sharper line than a digital sensor can
SFS
0.5-0.6 mm
LFS
1.0-1.2 mm
Typical LCD monitor
0.15-0.2 mm pixels
When it comes to spatial resolution, techs should always use:
small focal spot size, maximum SID, and minimum OID
Matrix
a series of colums and rows
-digital image recorded as this
Pixels
picture elements
The larger the matrix size,
the smaller the pixel size which means the btter the spatial resolution
The smaller the pixel size,
the greater the spatial resolution
Pixel Pitch
the distance from the center of one pixel to the center of another adjacent pixel
Pixel pitch and pixels relationship
direct
- when pixels are smaller, pixel pitch is smaller
Pixel Pitch and Spatial Resolution relationship
indirect
the smaller the pixel pitch, means smaller pixel size and increases spatial resolution
Two types of images
Analog & Digital
Analog Image
captures a continuously changing signal, what the human eye needs to see the image
Digital Image
recorded as multiple values, divided into an array of smaller pieces (pixels)
-binary data, each pixed represented by a numerical value that correspons to a brightness level
Sampling Frequency
how often the analog signal is reproduced in its digitized form
- how frequently we take a sample
Increasing sampling frequency...
increases spatial resolution by decreasing pixel size and pixel pitch
Modulation
the process of varying a property of waveform
-for x-ray we dont want this
Modulation Transfer Function
the ability of the imaging system to render objects of different sizes onto an image or to display small objects
A perfect system would have an MTF of...
1 or 100%
High MTF results in...
very little change in wave form which is what we want, and a good SR
Low MTS results in...
the wave form changing a lot which is what we dont want, and bad SR
Which objects are harder to image?
objects with higher spatial frequency so smaller objects
With increasing spatial frequency, line pairs become more...
blurred because they are smaller
Signal to noise ration (SNR)
noise that is related to less photon (quantum), which limits the ability to see an objects edge
-want signal high and noise to be 1
Signal to noise ratio and spatial resolution relationship
the higher the SNR, the better the image in terms on spatial resolution
contast to noise ratio (CNR)
the overall grayscale quality of an image and how an image is percieved by the viewer
contrast to noise ratio and spatial resolution relationship
the more noise the less contrast visualized
Resolution Test Tools
plastic-encased lead bar patterns that are imaged to contruct a modulation transfer function