1/15
Vocabulary flashcards covering radiation detector efficiency, counting error statistics, confidence levels, and background radiation determination.
Detector Efficiency (Detector Yield)
The ratio that relates the number of pulses counted to the number of particles and/or photons incident on the detector, giving the fraction of counts detected per disintegration (c/d).
Percent Efficiency
The detector efficiency expressed as a percentage, calculated by multiplying the fractional efficiency (E=dpmcpm) by 100.
Correction Factor (CF)
The inverse of the detector efficiency (CF=E1), which is multiplied by the net count rate to determine the activity of a sample.
Reported Counting Data Format (x±y(Kσ))
The standard format for reporting counting measurements where x is the measured activity (in dpm, Ci, or Bq), y is the associated potential error, K is the multiple of counting error, and σ is the standard deviation at a stated confidence level.
Standard Deviation of a Single Count (σ)
In a normal or Gaussian distribution, the square root of the mean count, represented mathematically as σ=x.
Probable Error
A counting error level associated with a 50% confidence level, corresponding to an error multiplier (K) of 0.6745.
Standard Error
A counting error level associated with a 68% confidence level, corresponding to an error multiplier (K) of 1.0000 (1σ).
9/10 Error
A counting error level associated with a 90% confidence level, corresponding to an error multiplier (K) of 1.6449 (1.64σ).
95/100 Error
A counting error level associated with a 95% confidence level, corresponding to an error multiplier (K) of 1.9600 (2σ).
99/100 Error
A counting error level associated with a 99% confidence level, corresponding to an error multiplier (K) of 2.5750.
Simple Standard Deviation of a Count Rate
The standard deviation of a count rate determined by dividing the count rate (R) by the count time (T), calculated as TR.
Background Radiation
Radiation that enters the detector concurrently with radiation emitted from the sample, originating either from external natural sources (cosmic or terrestrial) or from inside the detector chamber that is not part of the sample.
Net Count Rate
The difference between the gross sample count rate and the background count rate, sometimes expressed in units of corrected counts per minute (ccpm).
Automatic Counting System Background Guidelines
Operational thresholds specifying that background should not exceed 0.5cpm alpha and 1cpm beta-gamma; exceeding these values requires cleaning or replacing the detector.
Second Detector (Background Reduction)
A secondary detector incorporated into counting systems to detect penetrating background radiation and internally subtract those counts from the gross sample counts over the same time period.
Chamber-Originated Background Contributors
Internal sources contributing to detector background, which include radiation emitted from detector materials, radioactive material on inside detector surfaces, radioactive material on the sample slide assembly, and contamination on the sample planchet or carrier.