Counting Errors and Statistics

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/15

flashcard set

Earn XP

Description and Tags

Vocabulary flashcards covering radiation detector efficiency, counting error statistics, confidence levels, and background radiation determination.

16 Terms

1
New cards

Detector Efficiency (Detector Yield)

The ratio that relates the number of pulses counted to the number of particles and/or photons incident on the detector, giving the fraction of counts detected per disintegration (c/d\text{c/d}).

2
New cards

Percent Efficiency

The detector efficiency expressed as a percentage, calculated by multiplying the fractional efficiency (E=cpmdpmE = \frac{\text{cpm}}{\text{dpm}}) by 100100.

3
New cards

Correction Factor (CF\text{CF})

The inverse of the detector efficiency (CF=1E\text{CF} = \frac{1}{E}), which is multiplied by the net count rate to determine the activity of a sample.

4
New cards

Reported Counting Data Format (x±y (Kσ)x \pm y\,(K\sigma))

The standard format for reporting counting measurements where xx is the measured activity (in dpm\text{dpm}, Ci\text{Ci}, or Bq\text{Bq}), yy is the associated potential error, KK is the multiple of counting error, and σ\sigma is the standard deviation at a stated confidence level.

5
New cards

Standard Deviation of a Single Count (σ\sigma)

In a normal or Gaussian distribution, the square root of the mean count, represented mathematically as σ=x\sigma = \sqrt{x}.

6
New cards

Probable Error

A counting error level associated with a 50%50\% confidence level, corresponding to an error multiplier (KK) of 0.67450.6745.

7
New cards

Standard Error

A counting error level associated with a 68%68\% confidence level, corresponding to an error multiplier (KK) of 1.00001.0000 (1σ1\sigma).

8
New cards

9/10 Error

A counting error level associated with a 90%90\% confidence level, corresponding to an error multiplier (KK) of 1.64491.6449 (1.64σ1.64\sigma).

9
New cards

95/100 Error

A counting error level associated with a 95%95\% confidence level, corresponding to an error multiplier (KK) of 1.96001.9600 (2σ2\sigma).

10
New cards

99/100 Error

A counting error level associated with a 99%99\% confidence level, corresponding to an error multiplier (KK) of 2.57502.5750.

11
New cards

Simple Standard Deviation of a Count Rate

The standard deviation of a count rate determined by dividing the count rate (RR) by the count time (TT), calculated as RT\sqrt{\frac{R}{T}}.

12
New cards

Background Radiation

Radiation that enters the detector concurrently with radiation emitted from the sample, originating either from external natural sources (cosmic or terrestrial) or from inside the detector chamber that is not part of the sample.

13
New cards

Net Count Rate

The difference between the gross sample count rate and the background count rate, sometimes expressed in units of corrected counts per minute (ccpm\text{ccpm}).

14
New cards

Automatic Counting System Background Guidelines

Operational thresholds specifying that background should not exceed 0.5 cpm0.5\,\text{cpm} alpha and 1 cpm1\,\text{cpm} beta-gamma; exceeding these values requires cleaning or replacing the detector.

15
New cards

Second Detector (Background Reduction)

A secondary detector incorporated into counting systems to detect penetrating background radiation and internally subtract those counts from the gross sample counts over the same time period.

16
New cards

Chamber-Originated Background Contributors

Internal sources contributing to detector background, which include radiation emitted from detector materials, radioactive material on inside detector surfaces, radioactive material on the sample slide assembly, and contamination on the sample planchet or carrier.