1/27
Looks like no tags are added yet.
isomoves
relocation of the isocentre about completed 3-point set-up
depends on the treatment technique being used
isocentric technique
an SAD (source axis distance) technique where the beam arrangement id focused around the iscentre for accurate targeting of the tumor while minimizing exposure to surrounding healthy tissue.
common examples of isocentric technqiues
conformal
IMRT
VMAT
POP
most isocentric techniques are ___-isocentric
mono-isocentric (but can also be dual-isocentric, multi-isocentric)
comformal 4 field box
4 beams of radiation, to distribute the radiation entry point (∴ ↓ dose)
radiation is focused on the tumour @ isocenter (where the highest dose is) — but also a lot of dose delivered to the healthy tissue
beams can be shaped with mlc

can beams be shaped in conformal technique
yes, shaped with mlc
conformal multifield
multiple beams of radiation, to distribute the radiation entry point (∴ ↓ dose)
radiation is focused on the tumour @ isocenter (where the highest dose is) — but also a lot of dose delivered to the healthy tissue
beams can be shaped with mlc
each beam delivers a uniform dose across the unshielded area
IMRT standards for
intensity modulated radiation therapy
IMRT
conformal multi-field but the beams have a non-uniform dose
MLCs can move in/out in patterns to change how the dose is delivered (modulate the dose)
high dose to tumour// low-dose + spare healthy/critical tissues
gantry will stop at determined angles to deliver the radiation, and beam will turn on/off as it progress through the treatment (step and shoot)
step and shoot
when gantry stops at pre-determined angles to deliver the radiation, and beam will turn on/off as it progresses through the treatment (+with changing MLC to adjust radiation to tumour shape)
j
VMAT stands for
gantry moves continously through arc formation,
beam is modulated and delivered seamlessly
fast and efficent (fast speed helps reduce pts likihood of movement during delivery)
VMAT
gantry moves continously through arc formation
beam is modulated (MLC) and radiation given seamlessly
when is IMRT and VMAT good to use
for sensitive critical structures in close proximity
according to video — useful for prostate treatments/CNS treatments
which technique has reference TSDs that need to be compared to
IMRT and VMAT — bc they rotate around continously, no discrete angle to be compared to??
which tecniques need daily imaging
IMRT, VMAT, multi-field conformal (maybeeee if in close proximity to critical structure)
how often to image IMRT technique
daily
how often to image VMAT imaging
daily
why does IMRT/VMAT need daily imaging
highly conformal and modulated — needs a lot of geometric accuracy (need to make sure pt is in real proper location)
ensure to not UNDERDOSE the tumour + OVERDOSE helathy tissue/critical strucutre
esp for H&N, lung, prostate, cervix, bladder, GI, CNS cases
how often to image with multifield conformal
more rare now… but ū use daily imaging
if NOT daily image ⟹ require…
simpler beam arrangement with larger field size
not in close proximity to critical structure (eg. spinal cord)
^^ ∴ may only require day 1 and weekly imaging
⟹ bc of larger treatment border and less concern over geographic
eg. 3-field rectum image
purpose of true beam portals
verify pts position
record of treatment
how often imaging of ‘true beam portals’
day 1 MV portal image of each treatment field
what structures can be visualized through 2D orthogonals
kV/kV pair or kV/MV pair (kV/kV is more common)
see bone
what can be visualized through CBCT
bone + all sites + soft tissue (only technique that can see soft tissue) tumor matching
used for lung, H&N, prostate, bladder
what structures can be visualized through 2D orthogonal and 3D CBCT
ū daily kV (orthogonal kV) + weekly CBCT
daily kV = align for treatment
weekly CBCT = infor about status of bladder/bowel filling
soft tissue visualization (of structures of nearby interested — eg. bladder, bowel filling assessment)
prostate, bladder
what anatomy structures should i use for image matching?
bone (main choice and most common)
soft tissue (only done for sites where its visible)
fiducial marker (eg. tattoo, gold seed etc.)
regions of interest (if doing a bony match, specfic bones/parts of bones that are more relevant to the tumor site = used to complete image match)
day ___ PI images are sent to ___ for _____
day 1 PI images are sent to RO for approval (yes, no, or if they want changes made prior to the 3rd day of treatment)
who are daily images sent to
reviewed by treating therapist (within a tolerance — eg. less than a certain amount, RT can make judgement of proceed,… but if greater = need to be sent to RO for review)
all images sent to RO for review and approval
if large discrepancy after shifts mean…
may need further imaging or re-positioning to ensure accuracy of treatment