isomoves

relocation of the isocentre about completed 3-point set-up

  • depends on the treatment technique being used


2
New cards

isocentric technique

an SAD (source axis distance) technique where the beam arrangement id focused around the iscentre for accurate targeting of the tumor while minimizing exposure to surrounding healthy tissue.

3
New cards

common examples of isocentric technqiues

  • conformal

  • IMRT

  • VMAT

  • POP


4
New cards

most isocentric techniques are ___-isocentric

  • mono-isocentric (but can also be dual-isocentric, multi-isocentric)


5
New cards

comformal 4 field box

  • 4 beams of radiation, to distribute the radiation entry point (∴ ↓ dose)

  • radiation is focused on the tumour @ isocenter (where the highest dose is) — but also a lot of dose delivered to the healthy tissue

  • beams can be shaped with mlc


<ul><li><p><strong><u>4 beams</u></strong> of radiation, to distribute the radiation entry point (∴ ↓ dose) </p></li><li><p>radiation is focused on the tumour @ isocenter (where the highest dose is) — but also a lot of dose delivered to the healthy tissue </p></li><li><p>beams can be shaped with mlc</p></li></ul><p></p>
6
New cards

can beams be shaped in conformal technique

yes, shaped with mlc

7
New cards

conformal multifield

  • multiple beams of radiation, to distribute the radiation entry point (∴ ↓ dose)

  • radiation is focused on the tumour @ isocenter (where the highest dose is) — but also a lot of dose delivered to the healthy tissue

  • beams can be shaped with mlc

  • each beam delivers a uniform dose across the unshielded area


8
New cards

IMRT standards for

intensity modulated radiation therapy

9
New cards

IMRT

  • conformal multi-field but the beams have a non-uniform dose

  • MLCs can move in/out in patterns to change how the dose is delivered (modulate the dose)

  • high dose to tumour// low-dose + spare healthy/critical tissues

  • gantry will stop at determined angles to deliver the radiation, and beam will turn on/off as it progress through the treatment (step and shoot)


10
New cards

step and shoot

when gantry stops at pre-determined angles to deliver the radiation, and beam will turn on/off as it progresses through the treatment (+with changing MLC to adjust radiation to tumour shape)

  • j


11
New cards

VMAT stands for

  • gantry moves continously through arc formation,

  • beam is modulated and delivered seamlessly

  • fast and efficent (fast speed helps reduce pts likihood of movement during delivery)


12
New cards

VMAT

  • gantry moves continously through arc formation

  • beam is modulated (MLC) and radiation given seamlessly


13
New cards

when is IMRT and VMAT good to use

  • for sensitive critical structures in close proximity

  • according to video — useful for prostate treatments/CNS treatments


14
New cards

which technique has reference TSDs that need to be compared to

IMRT and VMAT — bc they rotate around continously, no discrete angle to be compared to??

15
New cards

which tecniques need daily imaging

IMRT, VMAT, multi-field conformal (maybeeee if in close proximity to critical structure)

16
New cards

how often to image IMRT technique

daily

17
New cards

how often to image VMAT imaging

daily

18
New cards

why does IMRT/VMAT need daily imaging

  • highly conformal and modulated — needs a lot of geometric accuracy (need to make sure pt is in real proper location)

  • ensure to not UNDERDOSE the tumour + OVERDOSE helathy tissue/critical strucutre

  • esp for H&N, lung, prostate, cervix, bladder, GI, CNS cases


19
New cards

how often to image with multifield conformal

  • more rare now… but ū use daily imaging

    • if NOT daily image ⟹ require…

      • simpler beam arrangement with larger field size

      • not in close proximity to critical structure (eg. spinal cord)

      • ^^ ∴ may only require day 1 and weekly imaging

      • ⟹ bc of larger treatment border and less concern over geographic

    • eg. 3-field rectum image


20
New cards

purpose of true beam portals

  1. verify pts position

  2. record of treatment


21
New cards

how often imaging of ‘true beam portals’

day 1 MV portal image of each treatment field

22
New cards

what structures can be visualized through 2D orthogonals

kV/kV pair or kV/MV pair (kV/kV is more common)

  • see bone


23
New cards

what can be visualized through CBCT

bone + all sites + soft tissue (only technique that can see soft tissue) tumor matching

  • used for lung, H&N, prostate, bladder


24
New cards

what structures can be visualized through 2D orthogonal and 3D CBCT

  • ū daily kV (orthogonal kV) + weekly CBCT

    • daily kV = align for treatment

    • weekly CBCT = infor about status of bladder/bowel filling

  • soft tissue visualization (of structures of nearby interested — eg. bladder, bowel filling assessment)

  • prostate, bladder


25
New cards

what anatomy structures should i use for image matching?

  • bone (main choice and most common)

  • soft tissue (only done for sites where its visible)

  • fiducial marker (eg. tattoo, gold seed etc.)

  • regions of interest (if doing a bony match, specfic bones/parts of bones that are more relevant to the tumor site = used to complete image match)


26
New cards

day ___ PI images are sent to ___ for _____

day 1 PI images are sent to RO for approval (yes, no, or if they want changes made prior to the 3rd day of treatment)

27
New cards

who are daily images sent to

  1. reviewed by treating therapist (within a tolerance — eg. less than a certain amount, RT can make judgement of proceed,… but if greater = need to be sent to RO for review)

  2. all images sent to RO for review and approval


28
New cards

if large discrepancy after shifts mean…

  • may need further imaging or re-positioning to ensure accuracy of treatment