1/53
Looks like no tags are added yet.
Radiation protection
The practices used to minimize unnecessary exposure to ionizing radiation.
ALARA
As Low As Reasonably Achievable; keeping radiation exposure as low as reasonably achievable.
Three basic radiation protection principles
Time, distance, and shielding.
Time principle
Reduce exposure by spending less time near a radiation source.
Distance principle
Increase distance from a radiation source to reduce exposure.
Inverse square law
Radiation intensity decreases in proportion to the square of the distance from a point source.
Inverse square law formula
I1 × d1² = I2 × d2², where I is intensity and d is distance.
Shielding principle
Place appropriate absorbing material between a person and the radiation source.
Occupational exposure
Radiation exposure received while performing work duties.
Public exposure
Radiation exposure received by members of the general public.
Personnel monitoring
The use of dosimeters to measure or estimate an individual's occupational radiation exposure.
Personnel dosimeter
A device worn to monitor an individual's radiation exposure.
Film badge
A personnel monitoring device that uses photographic film to record radiation exposure.
Thermoluminescent dosimeter (TLD)
A dosimeter that measures radiation using light emitted from a heated material.
Optically stimulated luminescence (OSL) dosimeter
A dosimeter that uses light to stimulate a material and measure stored radiation information.
Pocket dosimeter
A small device that provides a direct or near-real-time indication of accumulated exposure; its design determines whether it can be reset.
Personnel dosimeter placement
Wear the dosimeter in the location required by facility policy; when a protective apron is worn, follow the applicable monitoring instructions.
Pregnant radiation worker monitoring
Follow facility and regulatory procedures for declaring pregnancy and any additional fetal monitoring.
Dosimetry report
A record summarizing an individual's measured or estimated occupational radiation dose.
Radiation Safety Officer (RSO)
The person responsible for overseeing the radiation safety program and related monitoring practices at a facility.
Field-survey instrument
A device used to measure radiation levels in an area rather than an individual's accumulated occupational dose.
Ionization chamber survey meter
A survey instrument that measures radiation by collecting ionization produced in a gas.
Geiger-Müller (GM) detector
A detector that uses gas ionization to detect radiation events; it is not equally suitable for every radiation measurement task.
Personnel dosimeter versus survey meter
A personnel dosimeter monitors a worker's dose; a survey meter measures radiation levels in an area.
Exposure unit
Traditional unit: roentgen (R); SI unit: coulomb per kilogram (C/kg).
Absorbed dose unit
Traditional unit: rad; SI unit: gray (Gy).
Equivalent dose unit
Traditional unit: rem; SI unit: sievert (Sv).
Effective dose unit
Traditional unit: rem; SI unit: sievert (Sv).
Radioactivity unit
Traditional unit: curie (Ci); SI unit: becquerel (Bq).
Gray conversion
1 Gy = 100 rad.
Rad conversion
1 rad = 0.01 Gy.
Sievert conversion
1 Sv = 100 rem.
Rem conversion
1 rem = 0.01 Sv.
Exposure conversion
1 R = 2.58 × 10⁻⁴ C/kg.
Curie conversion
1 Ci = 3.7 × 10¹⁰ Bq.
Becquerel
One nuclear transformation per second.
Absorbed dose
The radiation energy deposited per unit mass of material.
Equivalent dose
Absorbed dose adjusted for the type of radiation using a radiation weighting factor.
Effective dose
A radiation protection quantity that accounts for the differing radiosensitivities of tissues using tissue weighting factors.
Occupational whole-body dose limit
Traditional annual limit commonly taught in older radiography texts: 5 rem (50 mSv) per year; verify the limit and applicable rules required by your course.
Lens of the eye dose limit
The older textbook value commonly taught is 15 rem (150 mSv) per year; newer standards may differ, so use the value specified by your instructor.
Fetal dose limit during declared pregnancy
A commonly taught limit is 0.5 rem (5 mSv) for the entire pregnancy, subject to applicable regulations and course guidance.
Public dose limit
A commonly taught annual limit for public exposure from regulated sources is 0.1 rem (1 mSv), excluding specified exceptions and background or medical exposure.
Student radiation dose limit
For individuals under age 18, a commonly cited annual occupational limit is 0.1 rem (1 mSv); follow the applicable regulation and course material.
Skin and extremity dose limits
Use the specific limits and units in your assigned textbook or instructor's dose-limit chart; do not substitute the whole-body limit.
Dose-response relationship
The relationship between radiation dose and the biological response.
Linear dose-response
A model in which the response increases in direct proportion to dose.
Nonlinear dose-response
A model in which the response does not increase in direct proportion to dose.
Threshold model
A model in which an effect is not expected below a particular dose.
Nonthreshold model
A model that assumes there is no dose below which the risk of a stochastic effect is zero.
Linear-nonthreshold (LNT) model
A radiation protection model assuming stochastic risk increases proportionally with dose, with no risk-free threshold.
Stochastic effect
An effect for which probability increases with dose; severity is not determined by dose in the same manner as a tissue reaction.
Tissue reaction (deterministic effect)
An effect that generally has a threshold dose and becomes more severe as dose increases.
NCRP
National Council on Radiation Protection and Measurements, which issues recommendations and guidance on radiation protection.