Volume Median Diameter (VMD)
The midpoint droplet diameter where 50% of the total spray volume consists of droplets larger than the VMD and 50% consists of droplets smaller than the VMD, used to characterize spray quality, coverage, and drift potential.
Number Median Diameter (NMD)
The droplet diameter where 50% of the total number of spray droplets are smaller and 50% are larger, measured without reference to liquid volume to assess atomization efficiency.
Drift-Prone Droplet Threshold
Spray droplets smaller than 200μm (or 141μm in fine-spray evaluations), which are highly vulnerable to off-target airborne movement.
Large Droplet Deposition Limit
Spray droplets exceeding 600μm in diameter, which consume disproportionate liquid volume, deposit less effectively on foliar targets, and tend to roll off plant surfaces.
Droplet Volume-to-Diameter Relationship
The geometric principle stating that doubling the diameter of a spherical droplet (2×) increases its volume eightfold (8×) and reduces the total droplet count by eight times for a fixed liquid volume.
Coverage (Spray Application)
The total area of the target surface contacted by spray solution combined with the physical spatial distribution of droplets across that area.
ASAE S-572 Classification Categories
A standardized categorization of droplet spectra based on VMD ranges: Very Fine (<100μm, Red), Fine (100–175μm, Orange), Medium (175–250μm, Yellow), Coarse (250–375μm, Blue), Very Coarse (375–450μm, Green), and Extra Coarse (>450μm, White).
Spray Angle Effect on Droplet Size
The operational relationship where increasing the nozzle spray angle forms a wider, thinner sheet of liquid that breaks apart into smaller droplets.
Operating Pressure Effect on Droplet Size
The operational principle where increasing spray pressure forces fluid through the orifice with greater kinetic energy, reducing droplet size and increasing the proportion of drift-prone fines.
Orifice Size Effect on Droplet Size
The operational relationship where enlarging the nozzle exit orifice produces larger individual spray droplets under constant speed and pressure.
Coefficient of Variation (CV%)
A statistical measure of spray distribution uniformity across the boom; values below 15% are considered acceptable, while a value of 7% indicates extreme uniformity.
Droplet Density
The quantity of droplets deposited per unit target area, which is influenced by total spray volume, droplet size, and machine driving speed.
Tank Agitation Rate
The required continuous recirculating liquid flow to maintain homogeneous chemical suspension, which must equal 1% to 2% of the total tank volume per minute.

Jet Agitator
A hydraulic mixing component mounted inside a tank that uses a venturi orifice to entrain ambient fluid and multiply circulation volume.
Mesh Size (Screen Rating)
A rating indicating the number of interwoven wires per linear inch in a filter, where higher numbers represent smaller aperture openings (e.g., 20-mesh at tank opening, 50-mesh standard at nozzles, 100-mesh for small orifices).
Ball Valve
A low-restriction valve containing a ported sphere that provides a clean, straight-through flow path, primarily used for complete shut-off or full-flow delivery on water trucks, handlers, and sprayers.

Butterfly Valve
A quarter-turn valve with an internal hinged disk used for fluid flow throttling and rate control in automatic sprayer control systems.
Gate Valve
A linear-motion valve that lifts a barrier gate entirely out of the fluid conduit, imparting very low resistance to liquid movement.
Globe Valve
A screw-down shut-off and throttling valve where fluid changes direction through an internal baffle, causing a substantial pressure drop.
Conventional Boom Plumbing
A boom configuration in which liquid enters the center and can only exit through nozzle tips or dead-end boom flush caps, requiring boom priming and risking trapped chemical residue at the ends.
Re-circulating Boom
An advanced boom system that continuously circulates chemical mixture through the boom pipes and returns unused solution to the main tank, eliminating dead ends, reducing waste, and facilitating clean-out.
Wet Boom
A boom construction where the chemical solution flows directly inside the structural corrosion-resistant pipe that physically supports the nozzle bodies.
Dry Boom
A boom setup where solution is routed through individual flexible rubber or synthetic hoses to clamp-mounted nozzle bodies attached to a structural framework.
Diaphragm Check Valve (Nozzle Body)
A spring-loaded mechanism positioned inside each nozzle body that automatically closes against an opening when line pressure drops, eliminating post-shutoff nozzle dripping.
Nozzle Replacement Criteria
The industry standard dictating that an individual tip must be replaced if its measured flow output deviates by more than ±5% from the average of all boom nozzles, or exceeds manufacturer rating by over 10%.
Ceramic Nozzle Tip
An exceptionally wear-resistant nozzle material that maintains orifice geometry and calibration accuracy significantly longer than brass, nylon, or stainless steel when spraying abrasive formulations.
Standard ISO Nozzle Nomenclature
An international nozzle naming convention where digits indicate spray angle and calibrated flow rate in US gallons per minute at 40psi (e.g., 11002 designates a 110∘ fan angle delivering 0.2GPM).
Spray Overlap (Boom Height)
The proportion of the spray footprint that overlaps adjacent patterns along a boom; standard 46cm (18 in) boom height provides 30% overlap with 80∘ nozzles and 100% overlap with 110∘ nozzles.
Extended Range Flat Fan (XR)
A tapered-edge spray tip designed to maintain a consistent spray angle and uniform pattern across an expanded pressure spectrum from 15 to 60psi (1 to 4bar).
Even Flat Fan Nozzle
A specialized flat fan nozzle that produces an even, rectangular liquid distribution without tapered edges, engineered exclusively for non-overlapping band spraying over crop rows or backpack use.
Pre-Orifice Low-Drift Nozzle
A nozzle incorporating an internal restricting pre-orifice upstream of the exit orifice to induce an internal pressure drop, reducing drift-prone fines by approximately 50% relative to conventional flat fans.

Turbo TeeJet (TT) Nozzle
A wide-angle deflector-style spray tip with an internal pre-orifice and curved deflection chamber designed to minimize droplet fractioning and curb drift.

Air Induction (AI) Nozzle
A two-stage nozzle that uses a venturi orifice to suck in atmospheric air and blend it into the liquid stream, producing large air-filled droplets that minimize drift and shatter upon contact with plant surfaces.
Cone Nozzle (Hollow / Solid)
A circular spray pattern nozzle operating at 40 to 100psi to generate very fine droplets for deep canopy penetration during fungicide or insecticide spraying, offering zero drift reduction.
Flooding Nozzle (Deflector Tip)
A wide-angle deflector nozzle operated at low pressure to apply large liquid volumes with low drift, used for soil-incorporated chemicals, fertilizer, and roadside brush control.
Sprayer Calibration
The verification procedure of measuring and adjusting physical application equipment to guarantee that the actual volume delivered equals the target sprayer output rate.
Recommended Sprayer Output (Solution Rate)
The total volume of formulated pesticide blended with water carrier specified by label guidelines to be dispersed per unit treatment area, typically stated in gallons per acre (GPA) or liters per hectare (L/ha).

Roller Pump
A positive-displacement pump where rollers slide within slots in an eccentric rotor to push liquid; operates at 540 to 1000rpm, is prone to rapid wear from abrasive wettable powders, and requires a pressure relief valve.
Diaphragm Pump
A positive-displacement pump where reciprocating flexible diaphragms isolate abrasive spray chemicals from internal moving components, providing medium-to-high pressure capability.

Centrifugal Pump
A non-positive (variable) displacement pump operating at 3000 to 4500rpm that delivers high fluid volumes at low-to-medium pressures, tolerates abrasives well, and does not require a pressure relief valve.