high tissue sensitivity
lymphoid organs, bone marrow, gonads, alimentary tract-mucosa, skin, other organs with epithelial lining
intermediate tissue sensitivity
growing cartilage and bones, vessels
low tissue sensitivity
established tissues; mature bone/cartilage, muscle, nervous system
stochastic random effects
severity independent of dose, probability of occurrence increases w/dose
stochastic random effects has
no dose threshold; all or none phenomenon, there is no safe dose
2 examples of stochastic radiation effects
cancer and hereditary effects
deterministic radiation effect
a certain minimum dose must be exceeded before the effect occurs, severity increases w/dose
deterministic radiation effect has
a practical dose threshold
2 examples of deterministic radiation effects
cataracts and skin damage
ALARA
as low as reasonably achievable
ALARA purpose
making every reasonable effort to keep radiation exposures as far below dose limits as practical
3 core ALARA principles
time, distance, shielding
ALARA time
reduce exposure time, plan ahead to avoid retakes, limit ppl in room, rotate staff
ALARA distance
increase distance from source, inverse square law
inverse square law
intensity of the radiation decreases in proportion of the square of the change in distance (gamma and x-ray radiation)
2 ways to increase ALARA distance
chemical restraint and positioning aids
small animal positioning aids used to increase distance
sandbags, tape, v-troughs, sponges
large animal positioning aid used to increase distance
cassette holders
lead clothing only protects against
scatter radiation
single most important way to protect against the primary beam
collimation
recommended lead-equivalent thickness for shielding
2-5 mm Pb equivalent
storing lead garments
hung up, not folded
checking lead garments
radiograph them to check for cracks
2 shielding strategies besides lead clothing
stand-alone body shields, being out of the x-ray room
ALARA review and procedures
proper planning, collimation, regular equipment maintenance
personnel monitoring
is a legal requirement, use dosimeters
dosimeters
personal monitoring devices that can provide a permanent, legal record of an individualās occupational exposure to radiation
where to wear dosimeter
chest/neck area, wear with name plate facing source
occupational dose limit during a declared pregnancy
5 mSv/year
protocol for pregnant staff
declare it, and wear a fetal dosimeter
dose limit for non-occupational individuals over 18
up to 1 mSv/year
dose limit for occupational individuals
up to 50 mSv/year
radiograph
2D image of a 3D object
how many orthogonal projections should be obtained
2
2 things a radiographic projectionās name includes
direction of x-ray beam and area imaged
what additional info is added to name lateral projections
the side of recumbency
DP
dorsopalmar
DLPMO
dorsolateral-palmaromedial oblique
LM
lateromedial
DMPLO
dorsomedial-palmarolateral oblique
special projection technique that images the equine carpus tangentially
skyline projection, proximal and distal rows