1/50
Looks like no tags are added yet.
___________ or ____________ technique used to visualize the inside, or lumen, of blood vessels and organs of the body, with particular interest in the arteries, veins, and the heart chambers.
angiography or arteriography
Angiogram/arteriogram for _________
arteries
Venogram is __________ flow
venous
Angiography is performed by injecting a radio-opaque contrast agent into the blood vessel and imaging using X-ray techniques such as __________
fluoroscopy
- imaging that uses X-rays to obtain real-time moving images of the interior of an object. Allows see the internal structure and function of things in motion (blood flow, swalllowing etc).
fluroscopy
AKA the gold standard
digital subtraction angiography
This ____ is digitally subtracted from the post injection images to yield new images that display contrast only, increasing vessel visibility.
mask
Patient cooperation is required for success because _______ or ________ excursions cause mismatch (digital sutraction)
motion or respiratory excursions
However, the technique has the advantage of permitting substantial reduction in contrast loads.
digital subtraction
Technique
•Fills vessel lumen with iodinated contrast
•Contrast injection requires arterial access
•Exposed them to x-rays
•Detector and x-ray tube mounted on C arm
Digital subtraction angiography
Digital subtraction angiography provides high _________ resolution images
spatial
Limitations of digital subtraction angiography:
invasive
requires arterial puncture
complications at access site (bleeding, hematoma, PSA, AVF)
allergy to contrast
Can a patient with poor renal function get digital subtraction angiography?
no
CTA uses a ___________-___________ technique
cross sectional (axial)
Technique:
CT scanners are configured with an x-ray source mounted on a rotating ring.
•Scanner uses multiple detectors to acquire a volume of data.
•Contrast bolus and acquisition are timed to maximize resolution.
computed tomography angiography
Limitations of CTA:
calcifications hinder visualization of lumen
artifacts from surgical clips and prosthetics
allergy to contrast
pt with poor renal function
Can MRA be performed with contrast and without?
yes
Limitations of MRA:
metal devices
stents (artifacts)
claustrophobia
poor renal function (contrast)
Refers to a program for the systematic monitoring and evaluation of the various aspects of vascular testing to ensure that standards of quality are being met • Statistics are used to prove the diagnostic accuracy of vascular ultrasound testing
Quality assurance
QA
quality assurance
The science of making effective use of numerical data relating to groups of individuals or experiments • Deals with collection, analysis, and interpretation of data
statistics
Used to compare one form of a newer diagnostic test with another well-established and reliable test
GOLD STANDARD
Gold standard in vascular imaging is typically
angiography
Number of studies performed by ultrasound, which state that disease is present and agree with the gold standard
TRUE POSITIVES
Number of studies performed by ultrasound, which state that disease is NOT present and agree with the gold standard
TRUE NEGATIVES
Studies that are reported as positive by ultrasound but are found to be negative by the gold standar
False positives
Ultrasound states a study is negative; however, gold standard identifies disease.
FALSE NEGATIVES
The percentage of correct results overall • The degree of “closeness” of something to its actual value
ACCURACY
Calculated as the total number of correct tests divided by the total number of all tests
ACCURACY
Measures the proportion of actual positive studies that are correctly identified
sensitivity
Calculated by taking the true positives and dividing these by the all-positive results as determined by gold standard
sensitivity
The ability of a test to identify something as normal
specificity
Calculated by dividing the number of true negatives by all negative results as identified by the gold standard
specificity
The consistency of obtaining similar results under similar circumstances (accuracy over a period of time)
reliability
Proportion of patients with positive tests that are correctly identified
Positive predictive value
Calculated as the number of true positives divided by all the positive studies as identified by ultrasound (true positives and false positives)
positive predictive value
The proportion of negative test results when there is no underlying disease • Probability that a negative test reflects the absence of disease
negative predictive value
Calculated by dividing the true negatives by all negative test results (true negatives and false negatives)
negative predictive value
an assumption about a relationship between two variables.
hypotheses
assumes there is no relationship between two variables
NULL hypotheses
assumes there is a realtionship between two variables.
alternative hypotheses
The ______ hypothesis is tested and is either rejected or not rejected
NULL
is a number, calculated from a statistical test, that describes how likely you are to have found a particular set of observations if the null hypothesis were true
P value
is another way of saying that the p value of a statistical test is small enough to reject the null hypothesis of the test
Statistical significance
A chi square is used to test a _________
hypotheses
A statistical test that compares the difference between what you expect and what you observe
Chi-square test
Sensitivity calculation:
TP/ TP + FN
Specificity equation:
TN/ TN + FP
PPV equation:
TP/ TP + FP
NPV equation:
TN / FN + TN
Accuracy equation:
TP + TN / TP + FP + FN + TN