1/192
effect of an increase in kVp on compton scatter
decrease
energy range for photodisintegration
10 MeV
energy range for pair production
1.02 MeV
energy range for coherent scatter
< 10 keV
interactions with matter occurring in the diagnostic energy range
Compton scatter and photoelectric
The x-ray intensity is lower on the anode side of the tube because of the _____.
anode heel effect
as the angle of a target gets bigger, the effective focal spot will get ______
bigger
the effective focal spot is ____ than the actual focal spot
smaller
what makes a good contrast agent?
high mass density, high atomic number
the difference in x-ray interaction by various body tissue
differential absorption
differential absorption is dependent upon this
kV, Z number, mass density
used to make a uniform density on a radiograph for a non uniform part thickness
compensating filter
What happens to the x-ray beam when you increase the kV by 15%
you get the effect of the mAs doubling (increase in density)
circuits on the operating console are _____ voltage
low
how does AEC work?
exposure ends once a certain radiation level reaches the image receptor
Voltage ripple of high-frequency generator
Voltage ripple of single-phase generator
100%
Voltage ripple of three-phase, six-pulse generator
14%
Voltage ripple of three-phase, twelve-pulse generator
4%
If you have greater voltage ripple, you will have a ____ in image quality
decrease
If you have greater voltage ripple, you will have a ____ in image quantity
decrease
where radiation is made in the x-ray tube
anode
where electrons strike the target to make x-rays
focal spot
where electrons are boiled off
filament
what keeps the electrons together in a cloud near the filament
focusing cup
the kinetic energy of electrons is converted into mostly _____ in the x-ray tube
heat
_______ of the kinetic energy of electrons is converted into x-rays
two interactions that occur at the anode to produce radiation
characteristic and bremsstrahlung
five interactions in matter
coherent scatter, compton scatter, photoelectric absorption, pair production, photodisintegration
interaction at the anode where electron interacts with inner shell electron
characteristic
interaction at the anode where electron interacts with nuclear field and slows
bremsstrahlung
discrete portion of x-ray emission spectrum is from _____ radiation
characteristic
continuous x-ray emission spectrum is from _____ radiation
bremsstrahlung
to change the discrete x-ray emission spectrum, one would need to change this
atomic number of target material
electrical charge of an atom
0
electrical charge of an electron
negative
electrical charge of a proton
positive
electrical charge of a neutron
0
name the orbital shells from innermost to the fourth outer shell
K, L, M, N, O . . .
smallest part of an element
atom
smallest part of electromagnetic energy
photon
as the distance between the source and image increases, x-ray quantity at the image _____
decreases
as the wavelength of a photon increases, the energy of the photon ______
decreases
as the frequency of a photon increases, the energy of the photon _____
increases
like charges
repel
unlike charges
attract
unit of electric potential
volt
unit of electric charge
coloumb
unit of power
Watt
unit of electric current
amp
unit of electric resistance
ohm
rate of doing work
power
faraday proved what?
a magnetic field in motion could produce an electric current
Oersted proved what?
a current produces a magnetic field
an electric current is induced in a circuit if some part of that circuit is in a changing magnetic field defines ________
electromagnetic induction
removal of an electron from an atom
ionization
electron removed from atom and atom it originated from
ion pair
acronym for as low as reasonably achievable
ALARA
basic quanities in mechanical physics
mass, length, time
mass x distance
force
KE of random motion of molecules
heat
electrostatic force is directly proportional to the product of the electrostatic charges and inversely proportional to the square of the distance between them
coulomb's law
electric charge distribution is ______ in a diffuse nonconductor (electrified object - like a cloud)
uniform
electric charge distribution is ______________ in a conductor (like a wire)
concentrated along the sharpest curvature
xrays are produced in this part of the atom
orbital shells
gamma rays are produced in this part of the atom
nucleus
unit for patient dose
rad, Gray
unit for occupational dose
rem, Sievert
unit for radiation in air
roentgen, Coulomb per kilogram
unit for radioactivity
curie, Becquerel
1 R =
1 rad or 1 rem
SI unit of occupational dose
Sievert
SI unit of patient dose
Gray
Si unit of radiation in air
gray in air, Air kerma, or Coulomb per kilogram
SI unit of radioactivity
bequerel
what type of transformer has a single winding
autotransformer
the kV meter is on the ____ side of the x-ray circuit
primary
the mA meter is on the ____ side of the x-ray circuit
secondary
as voltage is _____, amperage decreases
increased
the focal spot selector is located in this portion of the x-ray circuit
filament circuit
a step up transformer is used in what part of the circuit?
between low and high voltage/between primary and secondary sides
a step down transformer is used in what part of the circuit?
filament circuit
the step up transformer changes _____ into _____
volts; kilovolts
emission spectrum: increasing mAs
increase amplitude
emission spectrum: increasing kV
increase amplitude and shift to right
emission specturm: increase filtration
decrease amplitude and shift to right
emission spectrum: increase atomic number of target material
increase amplitude and shift to right
When distance is doubled, intensity of x-ray beam is ______ by _______.
reduced; factor of four
controlling factors of beam quality
kV, filtration
controlling factors of beam quantity
mAs, kv, filtration - mAs being the main controlling factor
beam quantity is directly proportional to
mAs
HVL is a measurement of
beam quality
no ionization takes place in which of the radiation interactions with matter
coherent
No more electrons can be boiled off of the filament because of this phenomenon
space charge
What is a radiographic rating chart used for?
maximum exposure times
ways to increase efficiency of x-ray production
increase kV, increase atomic number of target material, use equipment with least voltage ripple
as the peak of the x-ray emission spectrum moves to the left, what is affected? How?
beam quality, decreases
electrons boiled off of the filament and being attracted to tungsten plating the inside of the x-ray tube
tube arcing
which way do electrons flow in the x-ray tube?
cathode to anode
which side of the beam is "hotter" or more intense?
cathode