AFM: Use of Flight Deck Auxiliary Power
Outlets in Flight Deck→supplies power to PEDS→P6 &P18.
Requires operational Regulatory Approval
AC Power Principles
1. No paralleling⚡:Only 1 AC source at a time: IDG / APU / External Power
2. Only ONE AC source can power AC Transfer Buses at a time
3. Automatic transfer 🔄: New source→AC Transfer Bus →Old source disconnects→Through BTBs
IDG Disconnect 🔧: Integral electro-mechanical device
Complete mechanical Isolation between IDG & Engine.
reactivation can only be done by ground maintnance
Electrical System Divisions
⚡ AC→8 buses
2 Transfer buses→Main distribution
2 Main buses→assosiated loads
2 Galley buses (C+D / A+B)
2 Ground Service buses→Certain equepments without AC on
🔋 DC→5 buses
2 DC buses
1 Battery bus
1 Hot Battery bus
1 Switched Hot Battery bus
🚨 Standby→7
Static INV
AC Standby bus
DC Standby bus
1 Main battery
Battery bus
Hot Battery bus
Switched Hot Battery bus
⚡ AC Power System
3-phase AC voltage: 115 V ±5%
Frequency: 400 Hz ±5%
Rated Output: 90 kVA
3 Sources:
2 IDGs
1 APU Generator→one or both TB through BTBs
1 External Power→ground elec. supply
🔋 DC Power System
Output: 28VDC
Supply: 3 Transformer Rectifier (TR) units
TR function: 115 AC → 28 DC
Standby Power
Battery
Type: Nickel-Cadmium (Ni-Cd).
Voltage: 24V DC ±4 V.
Operating range: 22–30V DC.
Fully charged → Minimum 30 min standby power (QRH).
⚡→🔋Transformer Rectifier (TR)
- Converts115 AC→28 DC
🔋→⚡Static Inverter (INV)
- Converts 24 DC → 115 AC
🔌 Battery Buses
Hot Battery Bus: Always connected to battery
Switched Hot Battery Bus: Powered when BAT switch ON
⚠ BAT DISCHARGE
- BAT switch ON + excessive battery discharge → BAT DISCHARGE light.
❄ Cold Weather Battery temperature below −18°C → Remove and store in warmer area (−18°C to below 40°C) to ensure APU starting capability.
Electrical Connections
🔌 Ground Service
Ground Service Bus 2 → Battery Charger TR.
External Ground Cart → Ground Service Buses 1 + 2.
⚡ Bus Tie Breakers (BTBs)
2 BTBs → Normally OPEN.
AC source failure/disconnection → Available source powers affected Transfer Bus through BTBs.
⚡ AC Transfer Buses
Transfer Bus 1 → AC Standby Bus + TR 1.
Transfer Bus 2 → TR 2 + TR 3.
🔋 TR Connections
TR 1 + TR 2 → DC Bus 1 + DC Bus 2 + DC Standby Bus (via Cross Tie Bus Relay).
TR 3 → Battery Bus + Backup for TR 1 & TR 2.
Any 1 TR fails → Remaining 2 supply total connected load.
🔄 DC Cross Bus Tie Relay
Normally CLOSED (connected).
Automatically OPENS when:
Glide slope capture during FD or A/P ILS approach → isolates DC Bus 1 from DC Bus 2, protecting NAV receivers and flight control computers from a single failure.
BUS TRANSFER switch → OFF.
🔋 Single Battery
Generator loss → Battery powers 4 DC buses:
DC Standby Bus
Battery Bus
Switched Hot Battery Bus
Hot Battery Bus
🔌 Ground Service Switch🔋
Ground power → AC Ground Service Buses only.
Location: FWD Attendant’s Panel.
Powers: Utility outlets, cabin lighting + battery charger.
Does NOT power: All airplane electrical buses.
🔋 Battery Charger TR – Single Battery
Restores & Maintains battery at full electrical power Powered by→ AC Ground Service Bus 2
Operation:
Primary charge cycle complete → Charger changes to Constant-Voltage TR mode
In TR mode, it supplies:
Hot Battery Bus
Switched Hot Battery Bus
Battery Bus → only if TR 3 fails
Standby power: Loss of AC Transfer Bus 1 OR power source to DC Bus 1 → Battery / charger supplies AC + DC Standby Buses.
Memory flow: Charge → Maintain → TR mode → Supply buses → Backup standby power.
⚡ Automatic Generator On-Line Feature
AC TAKES OFF with APU powering BOTH AC Transfer Buses, then APU SHUTDOWN / FAILURE → Engine Generators 🔄automatically connect to their RESPECTIVE Transfer Buses.
Activation occurs ONLY INFLIGHT
Visual memory: ✈ APU → BOTH BUSES → ❌ APU FAILS → ⚡ ENGINE GENERATORS TAKE OVER
APU Operation – Electrical Power Failure
ALL Generators INOPERATIVE + Battery is ONLY electrical power source → APU OPERATION.
⚠ APU start attempts NOT RECOMMENDED >⇡25,000 ft.
Visual memory: ⚡❌ No Generators,🔋 Battery Only → APU ON Below 25k’
ISFD (Integrated Standby Flight Display) – AFM
@ Electrical Power-Up: Do NOT move AC until ISFD Alignment is COMPLETE
@ Loss of STANDBY POWER (Main Battery)→ ISFD Dedicated Battery continues operating ISFD for an additional 150mins.
Visual memory: 🔋 Main Battery LOST → ISFD backup battery ⚡ → +150 MINUTES.
⚡🔋 TR UNIT (Transformer Rectifier Unit)
Failure conditions:
ON GROUND: Any ONE TR fails
INFLIGHT: TR 1❌ fails OR TR 2 + TR 3❌ both fail
QRH – Restrictions:
❌ Don’t use AFDS (Autopilot Flight Director System) APP (Approach) Mode during ILS APP
🚫 Autoland NOT AVAILABLE
Visual memory:
🛬 GROUND: Any 1 TR failure.
✈ INFLIGHT: TR 1 ❌ OR TR 2 + TR 3 ❌.
Both conditions → No AFDS APP Mode during ILS + No Autoland.
⚠Electrical Emergency
Only 1 AC ⚡ power source remains (Engine Generator OR APU Generator)
Flight crew must:
LAND at Nearest Suitable Airport.
DECLARE EMERGENCY.
Memory: 1 AC ⚡ source only → Nearest Suitable Airport + Declare Emergency.
🎛 Electrical Controls & Indicators
1. DRIVE – AMBER 🟠
Illuminates when IDG→LOW OIL PRESSURE,
caused by 4 conditions (IIIE):
I – IDG Failure.
I – IDG Automatic disconnect due to high oil temp.
I – IDG External/manual disconnect through GEN DRIVE (IDG) DISCONNECT switch
E –Engine Shutdown
2. ELEC
Illuminates ON GROUND ONLY when fault exists in DC 🔋 system or Standby Powersystem
⚠ QRH: NO-GO → DO NOT TAKEOFF.
3. STANDBY PWR OFF – AMBER 🟠
Illuminates when ONE OR MORE of these buses are unpowered:
AC ⚡ Standby Bus
DC 🔋 Standby Bus
Battery Bus 🔋
4. TRANSFER BUS OFF – AMBER 🟠
Illuminates when related AC ⚡ Transfer Bus is NOT POWERED.
5. SOURCE OFF – AMBER 🟠
Illuminates when:
No source has been MANUALLY SELECTED to power related Transfer Bus, OR
Manually selected source has been DISCONNECTED
Important: If a source is selected to power the OPPOSITE Transfer Bus, BOTH Transfer Buses are powered.
6. Circuit Breaker Panels
Behind (FO→ P-6) → CBs 1, 2, 3, 4, 11, 12 + SPCU.
Behind (Captain→P-18) → CBs 1, 2, 3.
Quick visual memory 🧠
Indicator | Meaning |
|---|---|
DRIVE 🟠 | IDG low oil pressure |
ELEC | DC 🔋 / Standby fault – Ground only |
STANDBY PWR OFF 🟠 | AC ⚡ / DC 🔋 / Battery Bus unpowered |
TRANSFER BUS OFF 🟠 | AC ⚡ Transfer Bus not powered |
SOURCE OFF 🟠 | No manually selected source / source disconnected |
⚠ Electrical Remarks
1. WHEEL WELL Fire Warning Test→on Overheat & Fire Protection Panel may or may not illuminate when testing on DC power Only.
For accurate testing, perform Wheel Well Fire Detection System test AFTER AC power is established
2. Extended APU Operation on Ground→required on ground while ac buses are powered by AC electrical power→ Position an AC-powered fuel pump ON to→Extends service life of APU Fuel Control Unit.
Engine Generators 🔄Automatic Load Shedding
During an OVERLOAD, Engine Generators automatically shed (disconnect) electrical loads/buses to reduce generator load.
Single Generator Operation
Load shedding occurs incrementally, according to actual load sensing:
Stage | Loads shed |
|---|---|
1st | Some buses are shed based on actual load sensing. |
2nd | Galley A+B + Main Bus 2 (Transfer Bus 2). |
3rd | If overload continues: Galley C+D + Main Bus 1 (Transfer Bus 1). |
Further shedding | If overload still exists: IFE buses are shed. |
Dual Generator Operation
NO LOAD SHEDDING,🔄Load Restoration
When configuration changes to more power sources (2 GEN operation):
→ Main Buses + Galley Buses + IFE Buses automatically restored
Manual Restoration: Cycle CAB/UTIL Power Switch:
OFF → ON to restore Galley & Main Bus power.
APU 🔄Automatic Load Shedding
During an OVERLOAD, the APU automatically sheds (disconnects) electrical loads/buses.
✈ Inflight – APU as the ONLY Power Source
Stage | Loads shed |
|---|---|
1st | All Galley Buses (A+B and C+D) + Main Buses 1 & 2 automatically shed. |
2nd | If overload continues, BOTH IFE Buses automatically shed. |
🛬 On Ground
APU initially attempts to carry FULL electrical load.
If overload occurs:
1-stage: All Galley Buses (A+B and C+D) + Main Buses 1 & 2 are shed until the load is within limits.
Manual Restoration: Cycle CAB/UTIL Power Switch:
OFF → ON
AC / DC Powered Equipment

⏱ Important time limits
Equipment | Duration |
|---|---|
Stall warning test | Up to 4 min |
Emergency Exit Light | 10 min |
CVR RIPS | 10 min |
Right IRS | 5 min only |
ISFD dedicated battery | 150 min |