Flashcards covering the mechanisms of radioactive decay (Beta, Positron, Electron Capture, Gamma) and the requirements for diagnostic radioisotopes in clinical settings.

11 Terms

1
New cards

Negatron (Beta-) Decay

A process occurring in neutron-rich nuclei where a neutron decays into a proton, a beta- particle (−1-1 charge), and an antineutrino, resulting in an unchanged atomic mass and an atomic number increase by 11.

2
New cards

Antineutrino

An entity almost without mass and charge that is primarily needed to conserve energy during beta- decay.

3
New cards

Positron (Beta+) Decay

Decay that occurs in neutron-deficient or proton-rich nuclei where a proton transforms into a neutron by emitting a β+\beta^{+} particle and a neutrino, reducing the daughter nuclide's atomic code by 11.

4
New cards

Positrons (β+\beta^{+})

The antimatter version of electrons which have the exact same mass as an electron but carry a +1e+1e charge.

5
New cards

Neutrino

A particle emitted during β+\beta^{+} decay and electron capture, described as the opposite of an antineutrino.

6
New cards

Electron Capture

A process common in heavier elements with a low n:pn:p ratio where an orbital electron is captured to transform a proton into a neutron and emit a neutrino, reducing the atomic number by 11.

7
New cards

Gamma Decay

The emission of gamma photons (waves with no mass or charge) from an excited nucleus to carry off excess energy, leaving the atomic mass and atomic number unchanged.

8
New cards

Target to non-target ratio

A value that should be high for diagnostic radioisotopes to maximize the efficacy of diagnosis and minimize the radiation dose to the patient.

9
New cards

Ideal Gamma-ray energies

The energy range for diagnostic radioisotopes preferred to be between 100100-250 keV250\,\text{keV}; values below 100 keV100\,\text{keV} or above 250 keV250\,\text{keV} are considered suboptimal.

10
New cards

Photon abundance

The quantity of photons which should be high for a radioisotope to minimize imaging and exposure time.

11
New cards

Diagnostic Half-life

A duration that must be long enough to enable analysis to be carried out but short enough to minimize radiation exposure to the patient.