Volumetric anylsis - theory without larger paragraphs

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/18

encourage image

There's no tags or description

Looks like no tags are added yet.

19 Terms

1
New cards

standard solution

solution whos concentration is accurately known

2
New cards

primary standard

substance which is pure, stable in air, has a high molar mass and can dissolve easily in water to directly make up a standard solution

3
New cards

Why is it not a primary standard? - sodium hydroxide

deliquescent - absorbs water from air to form solution

4
New cards

Why is it not a primary standard? iodine

sublimes close to room temp

5
New cards

Why is it not a primary standard?ammonia

volatile and escapes from solution into gas

6
New cards

What is a titration?

method of determining accurate concentration of a solution by reacting it with a solution of accurately known concentration

7
New cards

Q: How is a conical flask prepared for use?

must be clean and dry

8
New cards

why conical flask instead of beaker

shape allosws two solutions to be swirled without splashing

9
New cards

pipette function

transfer exact volume of solution

10
New cards

how to prepare a pipette for use

rinse with deionizied water, then with solution it will contain

11
New cards

how to fill a pipette

  • using a pipette filler, draw solution into pipette until its above grad mark

    • allow some solution to run out into a waste beaker so the bottom of miniscus rests on the grad mark at eye level


12
New cards

Delivering the solution in a pipette into a conical flask/beaker

transferred into conical flask by touching tip of the pipette against the inside of the flask, do not blow out last drop

13
New cards

prepare a burette

rinse with deionized water then with solution it will contain

14
New cards

how ot fill a burette

clamp it vertically, place a funnel on top, pour solution above grad mark, remove funnel, open tap and allow solution out so bottom of mensicus is at 0 when read at eye level

15
New cards

Q: When filling pipettes and burettes with solution, the solution is filled above the mark

before being drained out so the bottom of the meniscus rests on the mark. What is the

reason for this?

  • no air bubbles

  • tip is filled with solution



16
New cards

Q: Why is a white tile placed beneath the conical flask before a titration?

the endpoint

will be more accurately identified

17
New cards

procedures followed during a titration to obtain an accurate endpoint

  • continuously swirl the conical flask

    • use wash bottle of deionized waer to wash down the sides of the conical flask to ensure all solution from burette reacts with the conial flask


18
New cards

Q: Why is it acceptable at this stage to add deionised water to the conical flask despite

taking precautions when filling the pipette and burette to exclude deionised water

– the number of moles of the solute are now present

in the conical flask – adding deionised water at this stage will not change this

19
New cards

why rough titre

further titrations are more accurate and quicker