1/199
A set of 200 vocabulary flashcards covering the entire lecture transcript on basic electrical principles, AC/DC circuit analysis, electromagnetism, transformers, protective devices, rotating machinery, power systems, electronics, communication, and electrical installation practices.
Kirchhoff's Current Law (KCL)
The law stating that the algebraic sum of currents entering and leaving an electrical junction is zero.
Weber
The standard SI unit of magnetic flux.
Megohmmeter
A specialized measuring instrument used to measure high insulation resistance.
Conductance
The electrical property defined as the reciprocal of electrical resistance.
Coulomb
The standard SI unit of electric charge.
Ohm's Law
The fundamental law that explains the direct relationship between voltage, current, and resistance.
Siemens
The standard unit of electrical conductance.
Capacitor
An electrical component that stores energy within an electric field.
Inductor
An electrical component that stores energy within a magnetic field.
Hertz
The standard SI unit of frequency.
RMS Value (100V Peak)
The effective root-mean-square value of a sinusoidal voltage waveform with a peak value of 100V, equal to 70.7V.
Average Value of a Symmetrical Sine Wave
The average value of a symmetrical sinusoidal waveform calculated over one complete cycle, which equals zero.
Series Connection
An electrical circuit configuration in which the exact same current flows sequentially through every component.
Parallel Connection
An electrical circuit configuration in which the exact same voltage appears across every branch.
Impedance Unit
The measure of total opposition to AC current flow, measured in ohms (Ω).
Resistive Circuit Power Factor
The power factor of a purely resistive electrical circuit, which is equal to 1.
Purely Inductive Circuit Current Phase
The phase relationship in an ideal inductive circuit where alternating current lags applied voltage by 90∘.
Purely Capacitive Circuit Current Phase
The phase relationship in an ideal capacitive circuit where alternating current leads applied voltage by 90∘.
VAR (Volt-Ampere Reactive)
The standard electrical unit used for measuring reactive power in an AC circuit.
Volt-Ampere (VA)
The standard electrical unit used for measuring apparent power.
Joule
The standard SI unit of electrical energy.
Ohm
The standard SI unit of electrical resistance.
Thevenin's Theorem
A circuit analysis theorem stating that any linear bilateral network can be replaced by an equivalent circuit containing a single voltage source in series with a resistance.
Norton's Theorem
A circuit analysis theorem stating that any linear bilateral network can be replaced by an equivalent circuit containing a single current source in parallel with a resistance.
Maximum Power Transfer Condition
The network operating condition achieved when the load resistance equals the internal source resistance.
RC Time Constant
The characteristic time required for an RC circuit to charge or discharge, mathematically given by the formula RC.
RL Time Constant
The characteristic time required for an RL circuit current to change, mathematically given by the formula RL.
Capacitor DC Steady-State Behavior
The operating condition where an ideal capacitor acts as an open circuit to direct current in steady state.
Inductor DC Steady-State Behavior
The operating condition where an ideal inductor acts as a short circuit to direct current in steady state.
Newton per Coulomb
The standard SI unit of electric field strength.
Joule's Law
The physical law explaining the heating effect and rate of thermal energy generation produced by an electric current.
DC Electrical Power Formula
The mathematical equation expressing power in a DC circuit, defined as P=VI.
Conductor Resistance Temperature Dependence
The physical behavior characterized by an increase in electrical resistance as temperature rises in metallic conductors.
Ohm-meter
The standard unit of electrical resistivity.
Silicon
A group IV element widely used as the primary semiconductor material in electronic and solid-state devices.
P-Type Semiconductor Majority Carrier
The dominant positive charge carriers responsible for current conduction in P-type semiconductors, known as holes.
N-Type Semiconductor Majority Carrier
The dominant negative charge carriers responsible for current conduction in N-type semiconductors, known as electrons.
Energy Meter
An instrument designed specifically to measure and register electrical energy consumption over time.
Admittance
The measure of how easily a circuit allows alternating current to flow, defined as the reciprocal of electrical impedance.
Faraday's Law
The law stating that an induced electromotive force (EMF) is proportional to the time rate of change of magnetic flux linkage.
Tesla
The standard SI unit of magnetic flux density.
Mutual Induction
The electromagnetic principle utilized in transformer operation to transfer electrical energy between coupled coils.
Transformer Lamination
The construction of a magnetic core using insulated thin steel sheets to reduce internal eddy-current losses.
Open-Circuit Test
A standard transformer test conducted to determine core losses (iron losses) and no-load parameters.
Short-Circuit Test
A standard transformer test performed at reduced voltage to determine full-load copper losses and equivalent impedance.
kVA Transformer Rating
The standard apparent-power rating applied to transformers because core losses depend on voltage and copper losses depend on current, independent of power factor.
Step-Up Transformer
A transformer whose secondary winding has more turns than the primary, thereby increasing output voltage.
Transformer DC Incompatibility
The inability of a transformer to operate on steady DC because constant current produces no time-varying magnetic flux.
IEEE Device 87
The standard IEEE device number designation for a differential protective relay.
IEEE Device 50
The standard IEEE device number designation for an instantaneous overcurrent relay.
IEEE Device 27
The standard IEEE device number designation for an undervoltage relay.
IEEE Device 59
The standard IEEE device number designation for an overvoltage relay.
IEEE Device 52
The standard IEEE device number designation for an AC circuit breaker.
IEEE Device 32
The standard IEEE device number designation for a directional power relay or reverse-power relay.
Fuse
A sacrificial protective device containing a fusible link that melts to interrupt an electrical circuit during excessive current flow.
Circuit Breaker
An electromechanical protective switching device that interrupts fault current and can be mechanically reset.
Differential Relay
A protective relay that operates based on a measured difference between incoming and outgoing currents in a protected zone.
Lightning Arrester
A protective surge-diverting device designed to protect power system apparatus and insulation against high-voltage surges.
Current Transformer (CT)
An instrument transformer whose primary winding is connected in series with the line to step down current for metering and protection.
Potential Transformer (PT)
An instrument transformer connected in parallel across the electrical line to step down high voltages safely for measurement.
Open-Circuited CT Secondary Hazard
The dangerous condition whereby open-circuiting an energized CT secondary induces dangerously high voltage across its terminals.
Buchholz Relay
A gas-actuated protective relay installed on oil-immersed transformers to detect internal faults and abnormal gas accumulation.
Creosote
A chemical wood preservative widely applied to protect wooden utility and transmission poles from termite attack and fungal decay.
Silicon Steel
An alloy steel containing silicon that is commonly used to fabricate low-loss, high-permeability transformer cores.
Transformer Insulating Oil
A highly refined mineral oil whose primary purposes are to provide dielectric insulation and dissipate heat via cooling.
Transformer Breather
An auxiliary apparatus fitted to an oil conservator to remove atmospheric moisture from air entering the transformer tank.
Silica Gel
A porous, granular desiccant material packed inside a transformer breather to absorb ambient moisture from circulating air.
ONAN Cooling
A transformer cooling classification denoting Oil Natural Air Natural circulation.
Transformer Conservator
An external auxiliary oil reservoir mounted above a transformer tank to accommodate the thermal expansion and contraction of insulating oil.
Tap Changer
A mechanism attached to transformer windings allowing selection of turn ratios to adjust output voltage regulation.
Overcurrent Relay
A protective relay engineered to detect and respond when current exceeds a predetermined pickup threshold.
IEEE Device 51
The standard IEEE device number designation for an AC inverse-time or time-delay overcurrent relay.
IEEE Device 81
The standard IEEE device number designation for an electrical frequency relay.
IEEE Device 79
The standard IEEE device number designation for an AC automatic reclosing relay.
IEEE Device 86
The standard IEEE device number designation for an auxiliary lockout relay.
Isolator (Disconnect Switch)
A mechanical switching device operated off-load to provide a visible, verifiable physical break for maintenance safety.
Thermal Overload Relay
A temperature-sensitive protective device designed to safeguard electric motors from sustained thermal overloads.
IEEE Device 49
The standard IEEE device number designation for a machine or transformer thermal overload relay.
Neutral Grounding Resistor (NGR)
A current-limiting resistor connected between a power system neutral and ground to restrict phase-to-ground fault current.
Line Differential Protection
A transmission line protection scheme that compares instantaneous currents entered and exited at opposite line terminals.
Alternator
A synchronous AC machine designed to convert mechanical input energy into alternating electrical power.
Alternator Generated Frequency
The electrical frequency produced by an alternator, determined strictly by its number of magnetic poles and rotational speed.
Synchronous Speed Formula
The fundamental formula relating rotational speed, supply frequency, and pole count, given by Ns=P120f.
Frequency of a 4-Pole, 1,800 rpm Alternator
The output frequency generated by a four-pole alternator operating at 1,800rpm, which equals 60Hz.
Synchronous Speed of a 6-Pole, 60 Hz Motor
The synchronous rotating field speed of a six-pole machine operating on a 60Hz supply, which equals 1,200rpm.
Asynchronous Motor
An alternative technical term for an induction motor, reflecting the fact that its rotor runs at a speed below synchronous speed.
Induction Motor Standstill Slip
The fractional slip of an induction motor when its rotor is completely stationary, equal to 1.
Synchronous Speed Slip
The fractional slip of an induction motor when theoretically rotating at exact synchronous speed, equal to 0.
DC Series Motor
A direct-current motor characterized by high starting torque, commonly utilized in heavy traction and crane applications.
DC Shunt Motor
A direct-current motor characterized by nearly constant operating speed across wide variations in mechanical load.
Commutator
A split-ring cylindrical mechanical assembly in a DC machine that reverses current direction within armature coils to maintain unidirectional torque.
Universal Motor
A series-wound commutator motor capable of operating efficiently on either alternating current (AC) or direct current (DC).
Brushes (DC Machine)
Stationary carbon blocks that maintain sliding electrical contact to transfer current between external terminals and the rotating commutator.
Armature Reaction
The distorting and demagnetizing effect exerted by the magnetic flux of the armature current upon the main field flux.
Motor Starter
An electrical apparatus designed to limit excessive starting current and provide overload and undervoltage protection during motor startup.
Star-Delta Starter
A reduced-voltage motor starting device that initializes a three-phase motor in star configuration before switching it to delta configuration.
Three-Phase Phase Displacement
The symmetrical electrical angular separation between the individual phase voltages of a balanced three-phase system, which is 120∘.
Line Current in Star Connection
The relationship in a star (Y) connection where line current is identical to phase current (IL=Iph).
Line Current in Delta Connection
The relationship in a delta (Δ) connection where line current equals 3 times the phase current (IL=3Iph).
Line Voltage in Star Connection
The relationship in a star (Y) connection where line voltage equals 3 times the phase voltage (VL=3Vph).