1/104
Looks like no tags are added yet.
Which of the following will NOT eliminate aliasing?
a. increasing the PRF
b. increasing the Nyquist limit above the frequency shift
c. decreasing the sample depth
d. increasing the frequency shift above the Nyquist limit
d. increasing the frequency shift above the Nyquist limit
DOES eliminate aliasing:
-increasing the PRF = raises the Nyquist limit
-increasing Nyquist limit above frequency shift = directly prevents aliasing
-decreasing sample depth = allows higher PRF, which increase Nyquist limit
The "useful" artifact that one might see behind a weakly attenuating structure is:
a. shadowing
b. enhancement
c. reflection
d. refraction
b. enhancement
Along with image depth, which of the following also determines the frame rate?
a. axial resolution
b. damping
c. number of lines per frame
d. lateral resolution
c. number of lines per frame
True or False.
Compression allows us to see all gray shades.
True
True or False.
Piezoelectric crystal vibrates with a magnitude related to pulser voltage.
True
What system setting should be adjusted if you cannot see reflectors in the far field of your image?
a. TGC
b. period
c. depth
d. PRF
a. TGC
Which of the following is not adjustable by the sonographer?
a. compensation
b. compression
c. amplification
d. demodulation
d. demodulation

The principle stating that an increase in velocity within a stenosis must be accompanied by a corresponding decrease in pressure is:
a. Reynold's Number
b. Snell's Law
c. Bernoulli's Principle
d. Lenz's Law
c. Bernoulli's Principle
Bernoulli's principle is derived from the principle of conversation of energy.
Which of the following best describes the frame rate?
a. the frame rate is qual to the PRF multiplied by the lines per frame
b. the frame rate is equal to the PRF divided by the lines per frame
c. the frame rate is equal to the PRP divided by the lines per frame
d. the frame rate is equal to the PRP multiplied by the lines per frame
b. the frame rate is equal to the PRF divided by the lines per frame
Tframe = # pulses x PRP
Frame rate = PRF / lines per frame
Which of the following best describes sound waves?
a. a series of compression and rarefactions
b. waves that make dogs howl
c. waves that heat food
d. wave that make images
a. a series of compression and rarefactions

How many Hertz is 4 MHz?
a. 4,000,000
b. 4,000
c. 400
d. 400,000
a. 4,000,000
If the intensity remains the same while the power is doubled, the beam area is:
a. quadruple
b. doubled
c. halved
d. unchanged
b. doubled
I = P/A (Intensity = Power / Area)
Intensity and Power are directly proportional.
Intensity is inversely related to Area
*If Power is fixed, Intensity will decrease as Area increases

True or False.
The greater the difference between acoustic impedance values of two interfaces, the greater the reflection coefficient.
True
Identical impedance = no reflection
Slightly different impedance = small reflection
Largely different impedance = large reflection
Attenuation is determined by:
a. path length
b. frequency
c. medium
d. both a & b
d. both a & b
What kind of relationship do intensity and power have?
a. direct
b. indirect
c. unknown
a. direct
I = P/A (Intensity = Power / Area)
Intensity and Power are directly proportional.
Intensity is inversely related to Area
Which of the following has the shortest wavelength?
a. low amplitude
b. high frequency
c. low frequency
d. high amplitude
b. high frequency
Wavelength and frequency are inversely related.

The PRP is defined as:
a. it is synonymous with pulse duration
b. duty factor
c. the time in which the pulse is "on"
d. the beginning of one pulse to the beginning of the next pulse
d. the beginning of one pulse to the beginning of the next pulse

The duty factor for continuous wave ultrasound is:
a. 100 %
b. 0
c. less than 100 %
d. 0.1 %
a. 100 %
When depth of view is shallow, the PRP is:
a. short
b. long
a. short
PRP and maximum imaging depth are directly related.
shallow depth = short PRP
deeper depth = long PRP
*PRF and imaging depth are inversely related*
shallow depth = high PRF
deeper depth = low PRF

Axial resolution is equal to:
a. 2 multiplied by SPL
b. 2 plus SPT
c. SPL divided by 4
d. one-half SPL
d. one-half SPL
Axial res. = SPL / 2
Axial res. = (wavelength x # cycles in pulse) / 2
Axial res. = (0.77 x # cycles in pulse) / frequency
Which of the following transducers has the shallowest focus?
a. 4 MHz, 4 mm crystal diameter
b. 6 MHz, 4 mm crystal diameter
c. 4 MHz, 6 mm crystal diameter
d. 6 MHz, 6 mm crystal diameter
a. 4 MHz, 4 mm crystal diameter
shallow focal depth = lower frequency, small crystal diameter
deep focal depth = higher frequency, larger crystal diameter
Which statement is NOT true regarding lateral resolution?
a. it is equal to beam width
b. it is improved by focusing
c. it is also known as azimuthal resolution
d. it remains constant throughout the scanning depth
d. it remains constant throughout the scanning depth
Lateral resolution is best near the focus or 1 near zone length from the transducer because there the beam is at it's narrowest point.
If the number of cycles in the transmitted pulsed wave is increased:
a. axial resolution is degraded
b. lateral resolution is degraded
c. spatial resolution becomes shorter
d. rate of attenuation is increased
a. axial resolution is degraded
Long pulses degrade axial resolution and create less accurate images.
Better Axial Resolution:
-shorter spatial pulse length
-shorter pulse duration (wide bandwidth)
-higher frequencies (shorter wavelength)
-fewer cycles per pulse (less ringing)
-lower numerical value
Which of the following crystals will produce sound with the lowest frequency?
a. thin and with low speed
b. thin and with a high speed
c. thick and with a low speed
d. thick and with a high speed
c. thick and with a low speed
high frequency = thin PZT, high speed, short wavelength
low frequency = thick PZT, low speed, long wavelength
What is the recirpocal of 4?
a. 1/2
b. 1/4
c, 1/5
d. 4/1
b. 1/4
Two waves are traveling in a medium and arrive at a location at the same time. What event takes place?
a. constructive interference
b. inference
c. destructive interference
d. interference
d. interference
Two types of wave interference are constructive interference (in-phase) and destructive interference (out of-phase).
If the amplitude of a wave is increased to 3 times its original value, how much of an increase does intensity receive?
a. 6 times
b. 3 times
c. 9 times
d. intensity would decrease
c. 9 times
I = A^2 I = 3^2
Intensity is proportional to amplitude squared.
(Power is also proportional to amplitude squared. P = A^2)
As frequency increases, the half-value layer:
a. increases
b. remains the same
c. decreases
c. decreases
HVL = 6 / frequency
Thin HVL = high frequency, increased attenuation rate
Thick HVL = low frequency, decreased attenuation rate
The ability to distinguish between adjacent structures producing echoes of similar amplitude is termed:
a. spatial resolution
b. axial resolution
c. lateral resolution
d. contrast resolution
d. contrast resolution
Contrast resolution is the ability to distinguish one shade of gray from another. AMPLITUDE is a clue.
True or False.
The major disadvantage of pulse inversion is that the frame rate is half that of fundamental imaging.
True
In pulse inversion harmonic imaging, two pulses are sent for each scan line (one normal, one inverted). Because the system must transmit and receive twice as many pulses, the frame rate is reduced by approximately half compared to standard fundamental imaging.

If the radius of a vessel increases, flow in the vessel:
a. reduces to half
b. decreases
c. increases
d. remains the same
c. increases
If radius increases then flow increases.
A group of 8 bits is called:
a. binary
b. bite
c. pixel
d. byte
d. byte
Nonthermal mechanisms may also be referred to as:
a. thermal mechanics
b. mechanical mechanisms
c. thermal indices
d. absorption influence
b. mechanical mechanisms
Nonthermal (mechanical) mechanisms consist of cavitation and radiation force.
True or False.
Write magnification is preprocessing.
True
Preprocessing:
-TGC -log compression
-write magnification -persistence
-spatial compounding -edge enhancement
-fill in interpolation
Postprocessing:
-any change after freeze frame
-read magnification -contrast variation
-black/white inversion -3-D rendering
True or False.
Laminar flow patterns are found abnormal physiological states.
False
Laminar flow patterns are found NORMAL physiological states.
Which of the following converts electrical energy into acoustic energy during transmission?
a. receiver
b. display
c. transducer
d. pulser
c. transducer
Focal depth is determined by:
a. transducer diameter
b. crystal thickness
c. frequency
d. both a & c
d. both a & c
Focal depth (also called focal length or near zone length) is the distance from the transducer to the narrowest part of the beam (the focus).
Transducer diameter AND frequency are directly related to focal depth.
Lateral resolution is equal to:
a. pulse length
b. beam diameter
c. cycle in a pulse
d. period
b. beam diameter
Lateral resolution is best at the focus, where the beam is the narrowest and changes with depth. (good within the focal zone)

In B-mode, amplitude information is presented on:
a. X - axis
b. Y - axis
c. D - axis
d. Z - axis
d. Z - axis
x - axis: reflector depth
z - axis: amplitude
There isn't a y -axis.
Which of the following determine the spread of sound in the far field?
a. crystal thickness and impedance
b. speed of sound in the ceramic and frequency
c. frequency of sound and density of the ceramic
d. diameter of the ceramic and the frequency of sound
d. diameter of ceramic and frequency of sound
Referring to beam divergence.
less divergence: larger crystal diameter, higher frequency
more divergence: small crystal diameter, lower frequency
The region or zone deeper than the focus, beyond the near field is:
a. near zone
b. Fraunhofer zone
c. focal zone
d. focus
b. Fraunhofer zone
Also called the far zone.

The sound beam can be focused by all of the following, except:
a. acoustic lens
b. curved crystal
c. matching layer
d. electronic focus
c. matching layer
The matching layer decrease reflection at the PZT/skin boundary, thereby increasing the percentage of transmitted sound between the active element and the skin. (1/4 wavelength thick)
Dividing a normal crystal element into many smaller elements is termed:
a. apodization
b. beam steering
c. channel
d. subdicing
d. subdicing
Reduces grating lobes that degrade lateral resolution.
Which of the following is the resolution in the third dimension of the beam?
a. lateral resolution
b. axial resolution
c. contrast resolution
d. elevational resolution
d. elevational resolution
Also called slice thickness.
Which type of resolution is an accurate representation of moving structures?
a. lateral resolution
b. azimuthal resolution
c. spatial resolution
d. temporal resolution
d. temporal resolution
Which of the following would cause a decrease in temporal resolution?
a. increased line density
b. decreased sector size
c. single transmit zone
d. increased PRF
a. increased line density
Better Temporal resolution:
-shallower imaging
-single focus
-narrow sector
-low line density
Which of the following electrical patterns produce electronic focusing of the ultrasound beam?
a. curved
b. slope
c. spiral
d. circular
a. curved

What mathematical processing technique is used to analyze the data and produce a spectral waveform?
a. amplitude shift
b. autocorrelation
c. amplitude sampling
d. Fast Fourier Transform
d. Fast Fourier Transform
Fast Fourier Transform (FFT) is used for pulse wave and color Doppler signals.
Autocorrelation is used for color Doppler only.
Which type of Doppler relies on strength of shift rather than frequency shift, determining only presence or absence of flow?
a. spectral Doppler
b. color Doppler
c. power Doppler
d. continuous wave Doppler
c. power Doppler

What is defined as the action of an acoustic field within a fluid to generate bubbles?
a. thermal index
b. cavitation
c. dehydration
d. streaming
b. cavitation
Two forms of cavitation are stable and transient (inertial, normal).

The type of cavitation when larger bubbles are produced and subsequently rupture is:
a. transient cavitation
b. normal cavitation
c. inertial cavitation
d. a, b, and c are correct
d. a, b, and c are correct
Bubbles do NOT burst in STABLE cavitation.

Comprehensive preventative maintenance must be performed at least:
a. daily
b. semiannually
c. annually
d. when a problem occurs
c. annually
When a reflector moved toward the transducer, what will happen to the reflected frequency?
a. increase
b. decrease
c. stay the same
d. it is impossible to predict
a. increase
Toward the transducer = higher reflected frequency (+ shift) than the transmitted frequency.
Away from the transducer = lower reflected frequency (- shift) than the transmitted frequency.
Doppler shift is directly related to transmitted frequency.
*if transmitted frequency doubles, measured Doppler shift doubles*
All of the following are considered to be part of nonthermal mechanisms of biologic effects except:
a. radiation forces
b. streaming
c. acoustic cavitation
d. tissue heating
d. tissue heating
Thermal mechanisms proposes bioeffects result from tissue temperature elevation (tissue heating).
What does the brightness of the dots that make up the spectral displays represent?
a. the number of red blood cells present
b. the velocity of the signal
c. the frequency shift
d. the amount of turbulence present
a. the number of red blood cells present
What term and philosophy relates the amount of exposure time for the sonographer and patient during a sonographic examination?
a. as low as reasonably active
b. nonthermal mechanism
c. as low as reasonably achievable
d. better safe than sorry
c. as low as reasonably achievable
ALARA
A shadow occurs when sound:
a. travels through an area of decreased attenuation
b. reflects off a weak attenuator
c. travels through a cystic structure
d. travels through an area of increased attenuation
d. travels through an area of increased attenuation
What component of the ultrasound machine is used to detect positive versus negative frequency shifts?
a. analog Doppler
b. oscillator
c. FFT
d. phase quadrature
d. phase quadrature
Phase quadrature (quadrature detection) is commonly used signal processing technique for bidirectional Doppler.
*determines the direction of flow as its related to the transducer*
When is Doppler shift the highest?
a. Doppler shift is unrelated to beam angle
b. when the beam is perpendicular to the direction of flow
c. when the beam is parallel to the direction of flow
d. when the beam is at a 45 degree angle to flow
c. when the beam is parallel to the direction of flow
Parallel to sound beam = 100 % entire velocity measured
Perpendicular = 0 % velocity measured
*At angles other than 0 degrees or 180 degrees, only a portion of true velocity is measured*
Which of the following techniques reduce the presence of grating lobes?
a. apodization
b. tissue harmonics
c. subdicing
d. all of the above
d. all of the above
Apodization alters electrical spike voltages and reduces lobe strength.
Tissue harmonics are produced only in the beam's main axis where the beam is strong, not in the weaker side lobes.
Subdicing divides crystals into sub-elements that act as one crystal, which reduces grating lobes.
Universal or standard precautions apply to all of the following except:
a. sweat
b. nonintact skin
c. blood
d. pleural fluid
a. sweat
When viewing sonographic images outside the clinical setting, all of the following information is required to be removed except:
a. patient's name
b. facility
c. date
d. image orientation
d. image orientation
Which of the following may result if the spectral Doppler gain is too high?
a. too much output power sent into the patient
b. undermeasurement of the velocities
c. overmeasurement of the velocities
d. an image that is too dark
c. overmeasurement of the velocities
Aliasing spectral Doppler results in errors in measuring high velocities.
An artifact that occurs when a sound beam bounces back and forth between two strong reflectors, creating a "step ladder-like" appearance is:
a. reverberation
b. side lobes
c. multipath
d. edge shadowing
a. reverberation

The low velocity component is missing on a spectral waveform. Which of the following should be adjusted to fix this?
a. gain
b. scale
c. wall filter
d. frequency
c. wall filter
Wall filter eliminates low velocity flows near the baseline of a Doppler spectrum.

Which test object uses a moving belt, vibrating string, or a fluid pump?
a. contrast resolution phantom
b. tissue-mimicking phantom
c. slice-thickness phantom
d. Doppler phantom
d. Doppler phantom

True or False.
Quality assurance is a methodical way of evaluating equipment's performance on a routine basis to ensure proper and accurate equipment function.
True
True or False.
Sonographers should never ask a patient their name and birthday before beginning an exam.
False
Sonographers should ALWAYS ask a patient their name and birthday before beginning an exam.
True or False.
Gloves can be used to replace hand washing.
False
Glove can't be used to replace hand washing.
The spatial pulse length:
a. determines penetration depth
b. usually decreases with increased frequency
c. is improved with TGC
d. determines lateral resolution
b. usually decreases with increased frequency
SPL is inversely related to frequency.
SPL is the distance a pulse occupies in space from start to end.
SPL = # cycles x wavelength
The attenuation coefficient for a 5 MHz transducer is:
a. 1 dB/cm
b. 2.5 dB/cm
c. 3 dB/cm
b. 2.5 dB/cm
attenuation coefficient = frequency / 2
att. coef. = 5/2
Which of the following will create the fastest speed of sound?
a. high density, high stiffness
b. high density, low stiffness
c. low density, high stiffness
d. low density, low stiffness
c. low density, high stiffness
increase stiffness = increased speed
increased density = decreased speed

Which of the following waves has the longest wavelength?
s. 2,455,000 Hz
b. 100 MHz
c. 2.4 kHz
d. 14,000 Hz
c. 2.4 kHz
Wavelength is inversely related to frequency.
shorter wavelength created by high frequency
longer wavelength created by low frequency

Increasing the PRP:
a. improves resolution
b. increases the maximum imaging depth that can be imaged
c. decreases the maximum depth that can be imaged
d. increase refraction
b. increases the maximum imaging depth that can be imaged
PRP and imaging depth are directly related.
shallow depth = short PRP
deeper depth = longer PRP

The go-return time for an object creating the reflection at 1 cm is:
a. 13 microseconds
b. 26 microseconds
c. 6.5 microseconds
a. 13 microseconds

Which transducer would have the shallowest focus?
a. lowest frequency and smallest crystal diameter
b. highest frequency and biggest crystal diameter
c. lowest frequency and largest crystal diameter
d. not enough information
a. lowest frequency and smallest crystal diameter
shallow focus = small diameter and lower frequency
deep focus = large diameter and higher frequency

Which transducer has the lowest intensity at the end of the near zone?
a. 4 MHz, 4 mm crystal diameter
b. 6 MHz, 4 mm crystal diameter
c. 4 MHz, 6 mm crystal diameter
d. 6 MHz, 6 mm crystal diameter
d. 6 MHz, 6 mm crystal diameter
Beams with deeper focus have lower intensity at the focus.
shallow focus = small diameter and lower frequency
deep focus = large diameter and higher frequency
Electronic slope results in steering of the sound beam. It is accomplished by altering the:
a. acoustic lens placement
b. electronic pattern for excitation of the crystals
c. mechanical pattern for excitation of the crystals
d. Z of the crystal
b. electronic pattern for excitation of the crystals

True or False.
Temporal resolution is an accurate representation of moving structures.
True
Which of the following is not true of the linear sequenced array transducer?
a. rectangular shape image
b. firing is in sequence
c. electronically focused
d. the elements are in a ring
d. the elements are in a ring
Linear sequenced array transducer elements are arranged in a straight line.
Annular phased array transducer elements are arranged in a ring.
Which of the following would be best to use for imaging deep structures in the abdomen?
a. endocavitary transducer
b. linear sequenced array transducer
c. curved array transducer
d. continuous wave transducer
c. curved array transducer
True or False.
The process of varying the voltage to transducer crystals so that the stronger electrical signals are used to excite the inner crystals within a group and progressively weaker electrical signals excite the outer crystals is known as subdicing.
False.
The process of varying the voltage to transducer crystals so that the stronger electrical signals are used to excite the inner crystals within a group and progressively weaker electrical signals excite the outer crystals is known as APODIZATION.
Which of the following will not affect temporal resolution?
a. line density
b. image depth
c. spatial pulse length
d. number of focal zones
c. spatial pulse length
Better Temporal resolution:
-shallower imaging
-single focus
-narrow sector
-low line density
SPL affects axial resolution.
If the fundamental frequency is 10 Hz, the harmonic frequency is:
a. 15 MHz
b. 5 MHz
c. 20 MHz
c. 20 MHz
Harmonic frequency is double the fundamental frequency.
The meaningful portion of the data is termed:
a. noise
b. signal
c. output
d. storage
b. signal
Noise is useless contamination.
In the exercising patient, the distal arterioles are dilated. What type of flow pattern would most likely be demonstrated on spectral Doppler within the proximal vessels?
a. monophasic flow
b. multiphasic flow
c. reversal of flow
d. respiratory phasicity
a. monophasic flow
During exercise, distal arteriole dilation lowers resistance, causing proximal arteries to display a low-resistance monophasic waveform.
The picture elements in the scan converter are termed:
a. decimals
b. binary numbers
c. bits
d. pixels
d. pixels
Coaptation is when a vessel:
a. collapses
b. explodes
c. has a stenosis
a. collapses
True or False.
The components earliest in the imaging chain, such as the transducer, process data with the widest dynamic range.
True

What is the maximum number of shade of gray in an 8-bit digital scan converter?
a. 16
b. 32
c. 64
d. 256
d. 256
2^8
The calculation used to predict the maximum temperature elevation in tissues as a result of absorption of sound is the:
a. spatial temporal index
b. nonmechanical index
c. mechanical index
d. thermal index
d. thermal index
What is it called when the 2D image, color Doppler, and spectral Doppler are displayed simultaneously?
a. duplex imaging
b. triplex imaging
c. multiplex imaging
b. triplex imaging
True or False.
Increasing the PRF/scale setting on spectral Doppler decreases the potential for aliasing.
True
When PRF/scale is increased to maximum so is the Nyquist limit so aliasing is less likely to appear.
Which of the following statements is true concerning biological effects of diagnostic sonography?
a. No harmful effects caused by exposure from present diagnostic ultrasound instruments have been reported in human patients in the absences of contrast agents.
b. The only biological effect of diagnostic ultrasound exposure is cavitation.
c. Biological effects have been recognized on a routine basis and the risk versus benefit must be considered for each ultrasound exam order.
a. No harmful effects caused by exposure from present diagnostic ultrasound instruments have been reported in human patients in the absences of contrast agents.
What type of errors will cause artificial echoes to appear within a cystic structure?
a. slice thickness
b. vertical calibration
c. registration
d. contrast resolution
a. slice thickness
Slice artifact fills in hollow structures such as cysts.
Artifacts relating to propagation speed occur because:
a. the machine can measure the propagation speed of tissue
b. the beam bounces off strong reflectors
c. the beam travels in a straight line
d. the machine assumes 1,540 m/s for all tissue
d. the machine assumes 1,540 m/s for all tissue
Speed error characteristics:
-correct # reflectors
-improper depth
-appears as "step-off"

In the image above, what direction is the blood flowing in the top vessel?
a. unable to determine
b. retrograde
c. right to left
d. left to right
d. left to right
BART
Blue away, Red towards

What adjustment should be made to optimize the color Doppler on this image?
a. no adjustment needed
b. decrease color gain to correct aliasing
c. decrease PRF to correct aliasing
d. increase color gain to correct aliasing
a. no adjustment needed

In the image above, what correction should the sonographer make to optimize the Doppler image?
a. increase the PRF
b. increase the color gain
c. decrease the color gain
d. increase wall filter
c. decrease the color gain

What is seen at the location of the arrow in this color Doppler image?
a. color aliasing
b. incorrect PRF setting
c. color flow reversal
d. normal vascular color fill
c. color flow reversal