1/31
Looks like no tags are added yet.
Payback Period
Payback Period = Initial Investment / Annual Savings
Synchronous Speed
f = frequency = 60 when not given
P = poles

Back EMF
Eback = back emf
Vs = supply voltage
Ia = armature current
Ra = armature resistance
I = total current
Ish= shunt field current

Pelton and Bucket: Ideal Flow Power
P = power
p = density
Q = flow rate
Vb = bucket peripheral speed
V1 = jet velocity
ϕ = bucket angle
θ = angle of deflection

Blade-Speed Ratio for Maximum Diagram Efficiency
p = blade speed ratio
Vb = blade tangential speed
Vj = jet velocity
α = nozzle angle at entrance

Specific Speed Two Nozzles (Nozzle Scaling)
n2 = modified number of identical nozzle
n1 = original number of nozzle

Mach Number
Vrel = relative velocity
Vsound = sonic velocity

Mach Number: Relative Velocity
Va = uniform axial velocity
Vb = blade velocity

Radial Centrifugal Compressor: Work done per kg of flow with Slip Factor
P = shaft/fluid power
p = density
Q = flow rate
m = mass flow rate
Vb = blade tip tangential velocity
Vw1 = Tangential (whirl) component of absolute inlet velocity. Because flow enters axially, there is no tangential swirl at inlet, so Vw1 = 0V
Vw2 = Tangential (whirl) component of actual absolute exit velocity.
SF = Slip Factor

Overall Efficiency of Anything
e_over = e1 x e2 x e3
Scaling Law

Weight of Foundation
Wf = weight of foundation
Wm = weight of machine
e = dynamic factor

Soil Bearing Capacity
Wf = weight of foundation
Wm = weight of machine
Sb = soil bearing capacity
A = foundation area

Water Power with Diameter and Velocity

Affinity Law

Velocity and Enthalpy Formula
h = enthalpy in kj/kg
v = velocity in m/s

Submersible Pump: Total Dynamic Head

Specific Speed with Nunber of Stages
N in rpm
Q in gpm
H in ft

Volumetric Efficiency

Volume Displaced
Vd = volume displaced
D = diameter or bore
L = length or stroke
N = seed
c = number of cylinders
x = acting or stroke

Phase Voltage of Wye Connection
Vl = line voltage
Vp = phase voltage

Total Air Power

Air Total Dynamic Head
hs = static head
hv = velocity head

Static Head

Velocity Head

Natural Frequency of Vibration
f = natural frequency
wn = angular frequency
k = spring stiffness
m = mass

Difference of VA and W units
VA = Apparent Power
W = Real Power
Factor of Safety of Soil Investigation
FS = factor of safety
Su = ultimate bearing capacity
Sb = soil bearing capacity
Sa = allowable bearing pressure

Volume of Foundation: Trapezoidal Prism

1:2:4 Concrete Mixture
1 yd³ concrete
6 sacks cement
0.44 yd³ sand
0.88 yd³ stone
Volume of Foundation: Block
Vf = L W H
Pump Energy Balance with Heat Loss
BP = WP + P_loss