Brooder Guard

Materials that are placed around the brooder stoves to prevent the chicks from straying too far away from the heat supply until they learn the source of heat.

2
New cards

Brooding

Process of supplying heat to the chicks after hatching up to the time that their natural heat regulatory mechanisms become fully functional.

3
New cards

Litter

Material used as bedding for animals.

4
New cards

Open-sided housing

Long and narrow type of houses wherein at least one-half of the front and the back of the house are open.

5
New cards

Enclosed housing

House wherein inside conditions are maintained as near as possible to the bird’s optimum requirements with the use of mechanical ventilation and artificial lighting.

6
New cards

suspended feeders

Roof structure shall be designed to carry additional dead loads such as _______.

7
New cards

Chicken Wire, Bamboo Slats

The walls should be made of suitable materials such as ____ or ____.

8
New cards

None

Provision to protect young chicks and older birds during periods of cold weather and extreme winds.

9
New cards

900 mm, 2 m

Entrance doors shall be at least ___ wide by ___ high and shall be made to swing inward. It shall be covered with 25 mm mesh wire netting.

10
New cards

25 mm

Entrance doors shall be at least 900 mm wide by 2 m high and shall be made to swing inward. It shall be covered with ____ mesh wire netting.

11
New cards

Both

Doors between pens shall be hung in pairs and be made to swing in ____ direction so that feed and litter carriers can be pushed through from either direction.

12
New cards

25 mm, 50 mm

In slotted floor, the width of the slat shall be ____ - ____ and the space in between slats shall be 25 mm – 38 mm. On top of the slats, plastic net or fish net with 25 mm holes shall be used.

13
New cards

25 mm, 38 mm

In slotted floor, the width of the slat shall be 25 mm - 50 mm and the space in between slats shall be _____ - _____. On top of the slats, plastic net or fish net with 25 mm holes shall be used.

14
New cards

25 mm

In slotted floor, the width of the slat shall be 25 mm - 50 mm and the space in between slats shall be 25 mm – 38 mm. On top of the slats, plastic net or fish net with ____ holes shall be used.

15
New cards

625 mm2

In slotted floor, if welded wire is used. It should have ____ mesh. The wire shall be supported every 300 mm.

16
New cards

300 mm

In slotted floor, if welded wire is used. It should have 625 mm2 mesh. The wire shall be supported every ____.

17
New cards

Droppings

In slotted floor, slats or wire floors shall be constructed in sections so that they may be removed when it is necessary to clean the ___ from under them, or when the house is cleaned.

18
New cards

900 mm, 200 mm

In slotted floor, the floor shall be elevated at least ____ from the ground and the posts should have a diameter of at least ____.

19
New cards

50 mm, 100 mm

In litter floor, litter material shall be at least ____ - ____ deep over the cemented floor. Around the cemented floor, there should be solid wall with a height of 600 mm to retain the litter

20
New cards

600 mm

Litter material shall be at least 50 mm - 100 mm deep over the cemented floor. Around the cemented floor, there should be solid wall with a height of ____ to retain the litter

21
New cards

Maximum total weight of the birds

Floor support shall be designed to carry concentrated loads such as the ____________________.

22
New cards

10 m, 12 m

For housing sizes, width of the pen shall be about ___ - ___.

23
New cards

terrain, length

The length of the house shall depend on the _____ of the land and on the ____ of the automatic feeding equipment.

24
New cards

Cardboard, 450 m

In the brooding area, it shall be surrounded with ____, metal sheeting or any hard board with a minimum height of ____ to protect the chicken from draught.

25
New cards

23 hours of light at 35 watt/m² of illumination

During the first 48 hours, these are the hours of light should chicks receive, and its illumination intensity.

26
New cards

3.5 watts of bulb for each 0.37 m² of floor space (bulb at 2.4 m height with a clean reflector)

Wattage of light bulb needed per 0.37 m² of floor space (first 48 hrs).

27
New cards

10 watt/m²

After the first 48 hours, this should the light intensity at floor level.

28
New cards

1 watt of bulb for every 0.40 m² (bulb at 2.4 m height with a clean reflector)

After 48 hours, this is the wattage of light bulb per 0.40 m² of floor space required.

29
New cards

120 mm above the birds’ backs (with adjustable hover height)

The minimum clearance between hover-type brooders and the birds’ backs.

30
New cards

Strategic

Thermometers shall be placed in ____ locations inside the poultry house in order to monitor the temperature

31
New cards

Higher, lowered

Temperature in the poultry house shall not be permitted to become ____ than the outside temperature during summertime. Temperature should be ____ by providing additional water troughs, roof sprinklers, foggers and fans.

32
New cards

At least 1 m

Width of aisles and walkways between doors walls.

33
New cards

Guard/Lip, 10 mm, 20 mm

Each feeding trough should have a _____ about ____ - ____ to prevent the feed from being scratched out or beaked out onto the floor.

34
New cards

Billing

Feeding trough should be provided with wire bars or grills to prevent scratching and _____.

35
New cards

slots

Round feeders should be provided with adjustable ____ to control feed flow. Edges of feeder pan should be rolled for safety.

36
New cards

Raised

As the flock grows, feeders shall be ____ to maintain the feed level at the same height as the back of the chickens.

37
New cards

Two (2) fount-type chick waterers

For every 100 chicks, number of fount-type waterers provided in the first 2 weeks.

38
New cards

Outside the edge of the hover

Position of waterers in relation to the hover.

39
New cards

After 2 days, on stands 25 mm high.

No. of days the waterers should be placed on stands, and height.

40
New cards

3.6 L

The capacity of each fount-type chick waterer.

41
New cards

Semi-circular and fairly wide

Shape and size waterers should have to facilitate cleaning.

42
New cards

Adjustable bracket

Waterers should be supported by this for easy adjustment.

43
New cards

removable stopper

Feature at the drainage end allows easier cleaning

44
New cards

Spaced uniformly

Waterers should be distributed in this way in the poultry house.

45
New cards

3 meters

Maximum distance a bird should travel to reach water

46
New cards

200 lux

Artificial lighting with an intensity of ____ (refer to Annex B) shall always be available for use during the night or darkened periods of the day.

47
New cards

Ridge or chimney openings on the downwind side of the building, preferably at the highest point.

Outlets location for natural ventilation

48
New cards

Through vent doors, curtains, or large openings along the long sides of the building.

Location of inlet for natural ventilation.

49
New cards

To maintain indoor temperature and ensure air exchange as weather changes.

Purpose of automatic controls in ventilation systems

50
New cards

Air exchange by adjusting inlet and outlet opening sizes.

Natural ventilation system controllers regulate this.

51
New cards

Pneumatic systems

  • Manual or motorized cable & winch systems

  • Motorized mechanical arms


Devices that can be used to adjust inlet/outlet opening sizes.

52
New cards

Side opposite to the prevailing winds

Fans should be installed in a mechanical ventilation system in what direction.