Brooder Guard
Materials that are placed around the brooder stoves to prevent the chicks from straying too far away from the heat supply until they learn the source of heat.
Brooding
Process of supplying heat to the chicks after hatching up to the time that their natural heat regulatory mechanisms become fully functional.
Litter
Material used as bedding for animals.
Open-sided housing
Long and narrow type of houses wherein at least one-half of the front and the back of the house are open.
Enclosed housing
House wherein inside conditions are maintained as near as possible to the bird’s optimum requirements with the use of mechanical ventilation and artificial lighting.
suspended feeders
Roof structure shall be designed to carry additional dead loads such as _______.
Chicken Wire, Bamboo Slats
The walls should be made of suitable materials such as ____ or ____.
None
Provision to protect young chicks and older birds during periods of cold weather and extreme winds.
900 mm, 2 m
Entrance doors shall be at least ___ wide by ___ high and shall be made to swing inward. It shall be covered with 25 mm mesh wire netting.
25 mm
Entrance doors shall be at least 900 mm wide by 2 m high and shall be made to swing inward. It shall be covered with ____ mesh wire netting.
Both
Doors between pens shall be hung in pairs and be made to swing in ____ direction so that feed and litter carriers can be pushed through from either direction.
25 mm, 50 mm
In slotted floor, the width of the slat shall be ____ - ____ and the space in between slats shall be 25 mm – 38 mm. On top of the slats, plastic net or fish net with 25 mm holes shall be used.
25 mm, 38 mm
In slotted floor, the width of the slat shall be 25 mm - 50 mm and the space in between slats shall be _____ - _____. On top of the slats, plastic net or fish net with 25 mm holes shall be used.
25 mm
In slotted floor, the width of the slat shall be 25 mm - 50 mm and the space in between slats shall be 25 mm – 38 mm. On top of the slats, plastic net or fish net with ____ holes shall be used.
625 mm2
In slotted floor, if welded wire is used. It should have ____ mesh. The wire shall be supported every 300 mm.
300 mm
In slotted floor, if welded wire is used. It should have 625 mm2 mesh. The wire shall be supported every ____.
Droppings
In slotted floor, slats or wire floors shall be constructed in sections so that they may be removed when it is necessary to clean the ___ from under them, or when the house is cleaned.
900 mm, 200 mm
In slotted floor, the floor shall be elevated at least ____ from the ground and the posts should have a diameter of at least ____.
50 mm, 100 mm
In litter floor, litter material shall be at least ____ - ____ deep over the cemented floor. Around the cemented floor, there should be solid wall with a height of 600 mm to retain the litter
600 mm
Litter material shall be at least 50 mm - 100 mm deep over the cemented floor. Around the cemented floor, there should be solid wall with a height of ____ to retain the litter
Maximum total weight of the birds
Floor support shall be designed to carry concentrated loads such as the ____________________.
10 m, 12 m
For housing sizes, width of the pen shall be about ___ - ___.
terrain, length
The length of the house shall depend on the _____ of the land and on the ____ of the automatic feeding equipment.
Cardboard, 450 m
In the brooding area, it shall be surrounded with ____, metal sheeting or any hard board with a minimum height of ____ to protect the chicken from draught.
23 hours of light at 35 watt/m² of illumination
During the first 48 hours, these are the hours of light should chicks receive, and its illumination intensity.
3.5 watts of bulb for each 0.37 m² of floor space (bulb at 2.4 m height with a clean reflector)
Wattage of light bulb needed per 0.37 m² of floor space (first 48 hrs).
10 watt/m²
After the first 48 hours, this should the light intensity at floor level.
1 watt of bulb for every 0.40 m² (bulb at 2.4 m height with a clean reflector)
After 48 hours, this is the wattage of light bulb per 0.40 m² of floor space required.
120 mm above the birds’ backs (with adjustable hover height)
The minimum clearance between hover-type brooders and the birds’ backs.
Strategic
Thermometers shall be placed in ____ locations inside the poultry house in order to monitor the temperature
Higher, lowered
Temperature in the poultry house shall not be permitted to become ____ than the outside temperature during summertime. Temperature should be ____ by providing additional water troughs, roof sprinklers, foggers and fans.
At least 1 m
Width of aisles and walkways between doors walls.
Guard/Lip, 10 mm, 20 mm
Each feeding trough should have a _____ about ____ - ____ to prevent the feed from being scratched out or beaked out onto the floor.
Billing
Feeding trough should be provided with wire bars or grills to prevent scratching and _____.
slots
Round feeders should be provided with adjustable ____ to control feed flow. Edges of feeder pan should be rolled for safety.
Raised
As the flock grows, feeders shall be ____ to maintain the feed level at the same height as the back of the chickens.
Two (2) fount-type chick waterers
For every 100 chicks, number of fount-type waterers provided in the first 2 weeks.
Outside the edge of the hover
Position of waterers in relation to the hover.
After 2 days, on stands 25 mm high.
No. of days the waterers should be placed on stands, and height.
3.6 L
The capacity of each fount-type chick waterer.
Semi-circular and fairly wide
Shape and size waterers should have to facilitate cleaning.
Adjustable bracket
Waterers should be supported by this for easy adjustment.
removable stopper
Feature at the drainage end allows easier cleaning
Spaced uniformly
Waterers should be distributed in this way in the poultry house.
3 meters
Maximum distance a bird should travel to reach water
200 lux
Artificial lighting with an intensity of ____ (refer to Annex B) shall always be available for use during the night or darkened periods of the day.
Ridge or chimney openings on the downwind side of the building, preferably at the highest point.
Outlets location for natural ventilation
Through vent doors, curtains, or large openings along the long sides of the building.
Location of inlet for natural ventilation.
To maintain indoor temperature and ensure air exchange as weather changes.
Purpose of automatic controls in ventilation systems
Air exchange by adjusting inlet and outlet opening sizes.
Natural ventilation system controllers regulate this.
Pneumatic systems
Manual or motorized cable & winch systems
Motorized mechanical arms
Devices that can be used to adjust inlet/outlet opening sizes.
Side opposite to the prevailing winds
Fans should be installed in a mechanical ventilation system in what direction.