boar
refers to a male breeding swine which is at least 8 months old
creep area
place for piglets inside the farrowing pen
culling rate
rate of removing undesirable or unproductive animals within the herd
dry sows
unbred sows which have just been weaned; non-pregnant sows
farrowing
act of giving birth in swine
farrowing pen
area in which a sow is confined during farrowing and lactation periods
farrowing stall/farrowing crate
device in which a sow is confined during farrowing and lactation periods and which prevents sow from turning around
fattener
swine raised for meat production usually starts at 15 kg
finisher
swine which are 66 kg and up
gilt
female swine that has not farrowed
grower
swine from 40 to 65 kg
litter
piglets born in one farrowing
litter index/farrowing index
average number of farrowings of one sow per year
occupancy
number of days an animal stays in a pen
sow
any breeding female pig that has farrowed
weaner/weanling
piglet that has been recently separated from its mother
One Unit System
In this system, the sows are removed when the piglets reach weaning age. The pigs remain in the same building from farrowing until they reach the desired weight for slaughtering.
Two Unit System
The sows and piglets remain in the farrowing house until the piglets are weaned. The weanlings are transferred to a growing-finishing house.
Three Unit System
The sows and piglets remain in the farrowing house until weaning. The weanlings are moved to a nursery house and finally a growing-finishing unit where they stay until they are ready for slaughter.
Four Unit System
The sows and piglets remain in the farrowing house until weaning. After weaning, piglets are moved to a nursery house, then to a growing house and finally to a finishing house until they are ready for slaughter.
At least 1 meter
Roof overhang measurement to ensure shade and to protect the swine from rain.
Gutter
Equipped in a roof so that rainwater can be drained away separately.
At least 2.4 m high
Ceiling height
1 m
Minimum height of sidewalls
Sidewalls
Exterior walls on the sides of the housing.
Solid Floors
Concrete floors shall be paved on a well compacted gravel fills.
2 - 4%
Floor shall be skid-resistant with _____ slope towards a gutter or drainage canal in solid floors.
Away
The direction of slope shall be ____ from the feeding trough in solid floors.
Slotted Floors
Should be made of concrete, plastic, metals or combination of such materials.
Slotted Floor
It shall be constructed to allow manure and urine to pass through.
Wood
Not recommended as flooring material because it is less durable, difficulty to dry hence may harbor pathogenic organisms, and splinters may cause injury to swine.
Partially Slotted Floor
Slats shall be placed perpendicular to the long dimension of pens.
Totally Slotted Floor
Slat should be place parallel to the sow’s body.
Partially Slotted Floor

Totally Slotted Floor

Concrete
_______ slats shall be used preferably for swine over 30 kg, including gestating sows.
19 mm
In concrete slat specifications, this is the distance between the optional steel bar to the top width.
No. 2 (6 mm)
Reinforcing bar in concrete design that can be omitted from cast-in-place slats.
38 mm
Distance from steel bar in concrete slat design to the bottom width using reinforcing bar #5.
51 mm
Distance from steel bar in concrete slat design to the bottom width using reinforcing bar #6.or larger bars.
Flattened Expanded Metal
For swine under 20 kg, ________ shall be used.
20 mm, 9 –11 gauge
Size of slat made of flattened expanded metal for swine under 20 kg.
300 mm
Supporting joists shall be spaced at _____ in the design of slat for swine under 20 kg.
5.3 mm (5 gauge)
Welded wire flooring shall be made of ______ wire spaced at 12.5 mm, 15 mm or 18 mm. It shall be supported every 300 mm.
12.5 mm, 15 mm or 18 mm
Welded wire flooring shall be made of 5.3 mm (5 gauge) wire spaced at _____, ______, or _____. It shall be supported every 300 mm.
300 mm
Welded wire flooring shall be made of 5.3 mm (5 gauge) wire spaced at
12.5 mm, 15 mm or 18 mm. It shall be supported every _____.
Welded wire flooring
It shall be made of 5.3 mm (5 gauge) wire spaced at 12.5 mm, 15 mm or 18 mm. It shall be supported every 300 mm.
Plastic flooring
It shall be coated with rough surface. Fiberglass reinforced T-slats should be used for creep areas in farrowing pens/crates and nursery. Slats shall be 38 mm wide and slots shall be 9 mm. It shall be supported every 600 mm.
Fiberglass Reinforced T-slats
It shall be coated with rough surface. _______ should be used for creep areas in farrowing pens/crates and nursery. Slats shall be 38 mm wide and slots shall be 9 mm. It shall be supported every 600 mm.
38 mm, 9 mm, 600 mm
Plastic flooring shall be coated with rough surface. Fiberglass reinforced T-slats should be used for creep areas in farrowing pens/crates and nursery. Slats shall be ___ wide and slots shall be ___. It shall be supported every ____.
Guardrail
In case rearing pen is used, ______ should be provided on both sides of the pen.
250 mm, 250 mm
In case rearing pen is used, guardrail should be provided on both sides of the pen. It should be fixed ____ from the pen wall and ____ above the floor.
10 - 14 mm
Weaners should be either penned in a ground pen or in an elevated nursery cages. These cages shall be provided with slatted floor with slot space clearance of _____ mm – ____ mm.
Same
It is recommended that the weaners with the ____ size shall be housed in a pen or cage.
25
Separate pens for growers should be provided. The size of each pen shall be designed to hold not more than ___ growers.
1.5 m x 4.8 m
Growing pen with a dimension of ____ x ____ shall accommodate 20 growers.
20
Growing pen with a dimension of 1.5 m x 4.8 m shall accommodate ___ growers.
25
Separate pens for finishers should be provided. The size of each pen shall be designed to hold not more than ___ finishers.
10
Finishing pen with a dimension of 1.5 m x 4.8 m shall accommodate __ finishers
1.5 m x 4.8 m
Finishing pen with a dimension of ___ x ___ m shall accommodate 10 finishers
0.66 m x 1.8 m
For a gestating pen, sows should be either housed individually (box/stall) or by group. For individual pen, the dimension should be ___ x ___.
Close
Pen for boars should be located ___ to the dry sow accommodation. The pen should be provided with a service crate.
Service Crate
Pen for boars should be located close to the dry sow accommodation. The pen should be provided with a ____.
160 mm -210 mm
Pen partitions should be either solid or slotted. The slot shall be within the range of ____ – ____.
Solid, Slotted
Pen partitions should be either ___ or ___. The slot shall be within the range of 160 mm – 210 mm.
Sharp
Fittings and internal surfaces to which the animals have access shall not have ___ edges or projections.
Paints
For pen partitions, surfaces shall not be treated with ____ that may cause illness or death.
10 mm, 30 mm
Pen gate should be made of at least ____ iron bars or at least ___ pipe fastened securely to a G.I. pipe frame.
600 mm, 0.9 - 1 m
The dimension of the pen gate shall be___ wide and ___ – ___ high.
750 mm
For weanling’s pen gate, a height of ____ shall be used.
1.5 m
Primary walkways
1 m
Secondary walkways
27 °C - 35 °C
Heaters shall be installed in creep areas to provide newborn pigs its required temperature of ___ - ___ until they are 3 days old.
3
Heaters shall be installed in creep areas to provide newborn pigs its required temperature of 27 °C - 35 °C until they are ___ days old.
762 mm, 152 mm
Heat lamps shall be placed ___ above the floor or ___ above the sow
300 mm, 250 mm
The feeding trough width shall be at least 300 mm and the depth shall be 250 mm.
feeding trough
Water trough or waterers shall not be placed beside the ________ to keep feeding area of the swine dry and clean. The linear space requirement for watering is the same for the space requirement for feeding.
the same
Water trough or waterers shall not be placed beside the feeding trough to keep feeding area of the swine dry and clean. The linear space requirement for watering is ____ for the space requirement for feeding.
1 cup / 20 weaners
No. of weaners per automatic watering cup or bowl
120 mm above floor
Height of the bottom rim of watering bowls for weaners
450–650 mm
Height of nozzle-type waterers to be installed for Sows & growing-finishing pigs
300 mm apart
Spacing requirement for nozzle-type waterers for Nursery Pigs
1 nipple / 10 nursery pigs
No. of Nursery Pigs per Nipple Waterer
1 nipple / 12–15 growing-finishing pigs
No. of Growing-Finishing Pigs per Nipple Waterer
450 mm apart
Spacing requirement for nozzle-type waterers for Growing Pigs
600–900 mm
Spacing requirement for nozzle-type waterers for Finishers & group-housed gestating sows
305 mm
Height of nozzle-type waterers to be installed for Weanlings
300 mm above floor
Height of the bottom rim of watering bowls for Finishers
1 cup / 12 gilts
No. of gilts per automatic watering cup or bowl
1 cup / 10 sows
No. of sows per automatic watering cup or bowl
Artificial
____ lighting shall always be available for use during the night or darkened periods of the day.
Natural Ventilation
Outlets should be either ridge or chimney opening on the downwind side of the building, preferably located at the highest point in a building.
Highest point
In natural ventilation, outlets should be either ridge or chimney opening on the downwind side of the building, preferably located at the ____ point in a building.
Inlets
In natural ventilation, this should be through vent doors, curtains or other large openings along the long sides of the building.
indoor temperature, air exchange
I natural ventilation, if necessary, automatic controls should be provided to maintain the _____ and provide ______ as weather changes hourly and seasonally.
pneumatic, winch, motorized
Natural ventilation system controllers should be available to regulate air exchange by adjusting inlet and outlet opening sizes. Various devices should be used to adjust the opening size: ____ systems; either manual or motorized cable and ___ systems; and ______ mechanical arms.
opposite
In mechanical ventilation, fans should be installed on the side ___ to the prevailing winds.
Water spray nozzles
______ should be provided to provide cooling effect. Nozzles should be placed approximately 1.8 m above the floor and pointing straight down to obtain the best pattern and cover the width of the pen.
1.8 m, down
Water spray nozzles should be provided to provide cooling effect. Nozzles should be placed approximately ___ above the floor and pointing straight ___ to obtain the best pattern and cover the width of the pen.
Mesh Wire
For the storage of feeds and supplies, a well-ventilated area should be provided and should be provided with ____.