ARRT Specification
SAFTEY
Components and operation
Quality control procedures
Warm Up and Inspection
Interlocks
Safety lights
Emergency switches
Critical machine parameters
Electrical and mechanical hazards
Imaging systems
Evaluation of QA results
Interpretation
Course of action
Documentation
Importance of Simulation
FIrst place in a patients course of tx
Identify exact location of tumor within the body
Identify the tumor's relationship to surrounding anatomy/critical structures
Determine the ideal patient position for tx
Simulation Process
Gather patient information
-Imaging studies
-Special considerations/instructions
Immobilization devices
Prep room
Patient Interaction
-Face photo
-Consent
Time out
Scout
Topogram
Simulation Instructions
Immobilization devices/indexing
Protocols and parameters
Mark isocenter (at tumor or on body)
Slice thickness/spacing
Photographs/set up notes, tattoos
Name 2 or 3 things to check at a time out?
Name, Date of Birth, Tx area, Fractionation, MU, Gantry angles
What are 2 or 3 things to look at in a chart check?
Consultation
Consent
Additional Imaging
Pathology
Simulation Order
BUN and Creatine levels
High Risk Patients
> 50 y/o
Diabetes
Kidney dysfunction
CV diease
What should you look for before giving Barium contrast
Risks such as perforation or ulceration
Adverse Reactions to Contrast
Can occur 30 mins after injection
Medical hx
Contrast reaction kit on hand always
CT Simulation
Produces images of high spatial resolution
Provides electron density information
Allows for smaller, more precise tx fields, unique field and beam arrangements tailored to the patient, better visualization
Increased dose to tumor
Decreased dose to normal tissue
DRRs can be manipulated to enhance tumor visualization
Hounsfield Units
CT number that describes attenuation/density
Gantry
Donut shaped part of CT
Traditional bore=70cm
Large bore=85cm
FOV is the actual width of the scanner's imaging capacity
Critical that the entire anatomy is in the FOV
When are DRRs first created for tx planning purposes?
the dosimetrist creates the DRR in treatment planning to give a clear reference image (from the planning CT)
Sim allows to import additional images for a more accurate tx planning
Daily QA
Tube warm up
Lasers (-/+ 2 mm)
Accuracy of CT #'s (HU) with phantom
Image noise evaluation
Electromechanical Features
Laser alignment
Table position
Gantry tilt position
Scan localization
Safety interlocks
Emergency off
DFOV is ____ than SFOV
Smaller
Average CT #'s in water and standard deviation
Frequency is daily
Phantom
Expected results: near 0
Acceptable range: -3/+3
High and low contrast resolution
Phantom with whole pattern
Frequency
Biannually (2 per year)
CBCT
QA image quality daily
Geometric accuracy
Patient dose (MV and KV)
MR Lin Acc
Imaging/scan time
Treatment
Magnetic field
Positioning lasers
Artifacts/patient selection criteria
Implanted tissue markers (MR safe)
Simultaneous acquisition of MR images
during treatment
May allow reduction of large margins