ARRT Specification

SAFTEY

Components and operation

Quality control procedures

2
New cards

Warm Up and Inspection

Interlocks

Safety lights

Emergency switches

Critical machine parameters

Electrical and mechanical hazards

Imaging systems

3
New cards

Evaluation of QA results

Interpretation

Course of action

Documentation

4
New cards

Importance of Simulation

FIrst place in a patients course of tx

Identify exact location of tumor within the body

Identify the tumor's relationship to surrounding anatomy/critical structures

Determine the ideal patient position for tx

5
New cards

Simulation Process

Gather patient information

-Imaging studies

-Special considerations/instructions

Immobilization devices

Prep room

Patient Interaction

-Face photo

-Consent

Time out

6
New cards

Scout

Topogram

7
New cards

Simulation Instructions

Immobilization devices/indexing

Protocols and parameters

Mark isocenter (at tumor or on body)

Slice thickness/spacing

Photographs/set up notes, tattoos

8
New cards

Name 2 or 3 things to check at a time out?

Name, Date of Birth, Tx area, Fractionation, MU, Gantry angles

9
New cards

What are 2 or 3 things to look at in a chart check?

Consultation

Consent

Additional Imaging

Pathology

Simulation Order

10
New cards

BUN and Creatine levels

11
New cards

High Risk Patients

> 50 y/o

Diabetes

Kidney dysfunction

CV diease

12
New cards

What should you look for before giving Barium contrast

Risks such as perforation or ulceration

13
New cards

Adverse Reactions to Contrast

Can occur 30 mins after injection

Medical hx

Contrast reaction kit on hand always

14
New cards

CT Simulation

Produces images of high spatial resolution

Provides electron density information

Allows for smaller, more precise tx fields, unique field and beam arrangements tailored to the patient, better visualization

Increased dose to tumor

Decreased dose to normal tissue

DRRs can be manipulated to enhance tumor visualization

15
New cards

Hounsfield Units

CT number that describes attenuation/density

16
New cards

Gantry

Donut shaped part of CT

Traditional bore=70cm

Large bore=85cm

FOV is the actual width of the scanner's imaging capacity

Critical that the entire anatomy is in the FOV

17
New cards

When are DRRs first created for tx planning purposes?

the dosimetrist creates the DRR in treatment planning to give a clear reference image (from the planning CT)

Sim allows to import additional images for a more accurate tx planning

18
New cards

Daily QA

Tube warm up

Lasers (-/+ 2 mm)

Accuracy of CT #'s (HU) with phantom

Image noise evaluation

19
New cards

Electromechanical Features

Laser alignment

Table position

Gantry tilt position

Scan localization

Safety interlocks

Emergency off

20
New cards

DFOV is ____ than SFOV

Smaller

21
New cards

Average CT #'s in water and standard deviation

Frequency is daily

Phantom

Expected results: near 0

Acceptable range: -3/+3

22
New cards

High and low contrast resolution

Phantom with whole pattern

Frequency

Biannually (2 per year)

23
New cards

CBCT

QA image quality daily

Geometric accuracy

Patient dose (MV and KV)

24
New cards

MR Lin Acc

Imaging/scan time

Treatment

Magnetic field

Positioning lasers

Artifacts/patient selection criteria

Implanted tissue markers (MR safe)

Simultaneous acquisition of MR images

during treatment

May allow reduction of large margins