New cards

3 things needed to produce x-rays

1. large potential difference between 2 electrodes

2. vehicle for the kinetic energy to travel

3. place for high-speed electrons to be stopped

interaction site

2
New cards

large potential difference

-between the (+) anode and (-) cathode

-(+) anode attracts the (-) electrons

-set by the kVp setting on operating console/control panel

3
New cards

Vehicle for kinetic energy:

electrons in the electron stream/beam

set by mA setting on the operating console

4
New cards

thermionic emission

number of electrons boiled off the filament wire

5
New cards

place for high-speed electrons to be stopped

anode target

actual focal spot

6
New cards

anode towards (+)

head of the table

7
New cards

(-) cathode towards

foot of the table

8
New cards

x-ray tube

Converts electrical energy to electromagnetic energy.

9
New cards

tube head assembly

tube stand

x-ray tube

collimator

10
New cards
<p>Floor mount</p>

Floor mount

track mounted on the floor

parallel to the long axis of the table

telescoping arm

best suited for LOW volume workloads

11
New cards

floor ceiling mount

2nd point of attachment

-floor/ceiling

-stabilty

12
New cards
<p>Overhead tube assembly</p>

Overhead tube assembly

most common

2 rails mounted on the ceiling

13
New cards
<p>protective housing</p>

protective housing

lead-lined metal structure

reduces electrical shock

reduces heat

reduces leakage radiation

14
New cards

Electrical Insulation

insulated cables

high voltage receptacles

15
New cards

thermal protection

-tube is immersed in oil bath - draws heat away

-cooling fans circulate air around the assembly - dissipate heat

16
New cards

thermal protection process produces

1% x-ray photons

99% heat

17
New cards
<p>leakage radiation</p>

leakage radiation

-photons traveling in directions other than toward the patient

-x-rays produced isotropically

-lead housing reduces leakage radiation

18
New cards

100 mR/hr at a distance of

3 feet

19
New cards

1 mgy/hr at a distance of

1 meter

20
New cards

what is tube enclosure surrounded by

oil to reduce heat

21
New cards

tube enclosure

"vacuum enclosure"

"envelope"

22
New cards

tube arching

vacuum is needed to eliminate electrons from colliding with air particles

'bronzes' or suntans' the glass

reduces x-ray production effciency

23
New cards

tube enclosure glass

made of pyrex

tube ages

tungsten vaporizes

arching

more heat resistant

24
New cards

tube enclosure metal

longer life

constant electric potential

less likely to fail

get very hot

25
New cards

target window

''port window''

thinner area of envelope

approx 5 cm opening

26
New cards

where does the primary beam exit

window

27
New cards

Cathode contains

Negative electrode

source of free electrons

filament wires

focusing cup

connecting wires

28
New cards

filaments

dual focus- 2 filaments

tungsten

thorium

29
New cards

thorium (1-2%)

increases emission of electrons

protects filament wire from heat damage

30
New cards

what causes higher amperage in the filament circuit increases thermionic emission

thermionic emission

31
New cards

space charge effect

point at which no more electrons can boil off

'cloud' of electrons around filament during thermionic emission

32
New cards

focusing cup

-negative charge

-repels negative electrons together into a cloud

-surrounds the filaments back/sides

33
New cards

focal spot blooming

Increase in focal spot size due to increased mA.

decreases:

-# of electrons striking the target

-x-ray production

-resolution

34
New cards

large filament wire

400 mA and up, larger body parts, many electrons, many photons needed, produce focal spots of 0.3 mm to 2 mm

35
New cards

small filament wire

• Under 400 mA settings

• Smaller body parts

• Less electrons; less photons needed

• Produce Focal Spots of 0.1 mm to 1 mm

36
New cards

anode

Positive electrode

source of x-ray PHOTONS

target for electron beam

decelerates the electron stream

37
New cards

focal track

area where electrons HIT the anode

''target''

38
New cards

stator

electromagnets

outside the enclosure

stationary

receives electric current

39
New cards

rotor

iron rod attached to target

inside the enclosure

rotates

does not receive electric current

40
New cards
<p>Stationary Anode</p>

Stationary Anode

smaller focal spot

electrons hit at same spot

high heat in one spot

lightweight

41
New cards
<p>Rotating Anode</p>

Rotating Anode

most common

larger focal spot

electrons strike around the track

heat dissipates over surface area

heavy

spreads out heat

42
New cards

Mutual Induction

converts electrical energy to mechanical energy

rotates the anode

electric current is supplied to the set of magnets in succession

43
New cards

rotor and stator

1. stators are energized in sequence

2. produces a changing magnetic field

3. induces a current to the rotor windings

4. creates magnetic field of the rotor

5. magnetic field of the rotor windings attempt to align to the magnetic field of the energized stator

6. causing rotor to rotate in a continous motion

44
New cards

actual focal spot

AT the anode

where electrons STRIKE the anode

45
New cards

effective focal spot

where photons EXIT the anode

exits the tube

primary beam

46
New cards

line focus principle

difference in ANODE angles

actual and effective focal spots change due to a change in anode angle

47
New cards

same filament wire size=

same electron stream

48
New cards

anode heel effect

Uneven distribution of radiation intensity in the x-ray beam.

high intensity closer to cathode side

49
New cards

major causes of x-ray tube failure

1. freuquent use of high exposure factors

2. long exposures times with lower mA

3. prepping without exposure

4. not warming up the tube

50
New cards

High Exposure Factors

High mA

High kVp

anode pitting

51
New cards

long exposure times

increased time

lower mA

anode melting

52
New cards

what happens if we prep without exposure?

-over loading the filament wire- damages breaks the filament wire

-wears out ball bearings around the rotor

-cracked anode

53
New cards

what happens during exposure switch HALFWAY down

-begins to rotate the anode

-applies positive charge to anode

-begins to heat filament wire

54
New cards

what happens when we depress exposure switch ALL the way down

-completes circuit

-positive charge in anode at full potential

-filament wire heated to max/electrons boiled off

-electrons travel from cathode to anode

55
New cards

proper tube managment

1. warm up tube

2. do not prep rotor excessively

3. do not rountinely use extreme exposure factors

56
New cards

components that decrease heat

oil bath

cooling fans

rotating anode

heat tolerating materials(tungsten)

protective circuits

57
New cards
<p>anode rating chart</p>

anode rating chart

-determines whether the tube can

-handle a certain technique setting

depends on generator phase being used

-3 exposure factors (kvp, ma, time)

58
New cards

above the curve in anode rating chart

unsafe

59
New cards

below the curve in anode rating chart

safe

60
New cards

calculate heat unit

HU= kVp x mA x S x C

61
New cards

HU= kVp x mA x S x C

HU- heat units

kVp- voltage

mA- current

s- time

c- generator correction factor

62
New cards

anode interactions

-electrons boiled off the filament wire

-(-) electrons from filament are attracted to anode

-filament electrons interact with tungsten atoms of the anode focal track

63
New cards

target interactions

99% heat cathode to anode

1% of interactions produce x-rays

-bremsstrahlung

-characteristic

64
New cards

Bremsstrahlung

Most of the x-rays produced the at target are ____.

germen word for "breaking" "slowing"

65
New cards

incident electrons

Electrons traveling from the cathode filament to the anode.

excite the tungsten atoms, but do not ionize them

66
New cards

incident electron causes outer shell electrons to

raise to a higher energy level

67
New cards

when tungsten electrons return to their energy level

heat is released

68
New cards

what increases heat at the anode

mA and Kvp

double= double heat

69
New cards

what increases energy and efficiency of the electrons striking the anode?

kVp

70
New cards
<p>characteristic interactions</p>

characteristic interactions

Produced when a projectile electron interacts with an electron from the inner (K) shell of the tungsten atom and ejects it. An outer shell electron drops into vacancy and the energy difference is emitted as an x-ray photon

ionizes tungsten atom

71
New cards

requires 70 kVp or HIGHER for the useful x-ray beam

characteristic interactions

72
New cards

why are the photons produced called characteristic

of the shell they orginate from with speficic energies

73
New cards

atomic number (z) of an element determines the ___ charge which determines the electron ___

nucleus; binding energies

74
New cards

characteristic cascade

The process of outer-shell electrons filling inner-shell vacancies, creating a cascading effect during a characteristic interaction.

75
New cards

insufficient energy

if the incident electron does not have enough energy to ionize the electron it strikes

76
New cards

ex: 50 kEv filament electron strikes a k-shell electron (69.5)

releases heat or

filament electron 'drifts' away to fill a vacancy in another atom or becomes part of the current through the tube

77
New cards

extra energy

if 100 Kev interacted with k-shell electron

30 keV would be left over to interact with another atom

(100-70)

78
New cards
<p>Bremsstrahlung Interactions</p>

Bremsstrahlung Interactions

Occur when a projectile electron completely avoids the orbital electrons of the tungsten atom and travels very close to its nucleus. The very strong electrostatic force of the nucleus causes the electron suddenly to "slow down." As the electron loses energy, it suddenly changes its direction, and the energy loss reappears as an x-ray photon.

79
New cards

increasing the atomic number

pulls filament electrons to nucleus

80
New cards

increased attraction

more high energy photons produced

81
New cards

What is brems photon energy?

The energy of the projectile electron when it enters the atom minus the energy of the electron as it exits the atom.

82
New cards

What is the most common energy of brems photon?

1/3 of the kVp set.

83
New cards

most photons produced are

BREMS

84
New cards

which photons are the only characteristic photons of sufficient energy to be useful

k-characteristic photons

85
New cards

emission spectrum

graphical representation of the radiation output of the tube

x-axis- energy/qualilty

y-axis- number/quantity

86
New cards

Bremmstrahlung photon energy can be affected by

kVp, filtration, target atomic #, generator efficiency

87
New cards

characteristic photon energy can be affected by

the target material's atomic #

88
New cards

what type of emission spectrum does characteristic have?

discrete

bar for each energy variation

89
New cards

what type of emission spectrum does bremsstrahlung have?

continuous

bell curve

energy from 0 to the max kVp

90
New cards

tube current

-mA

-affects amplitude

91
New cards

tube voltage

-kVp

-affects amplitude/position

92
New cards

Filtration

inherent (machine) & added

affects amplitude/position

93
New cards

generator type

voltage waveform

affects amplitude and postion

94
New cards

target material

affects amplitude/postion

95
New cards

increased mA

increase amplitude

96
New cards

decrease mA

decrease amplitude

97
New cards

mA and emission spectrum

no effect on energy

position of curve does not change

change in amplitude

98
New cards

kVp and emission spectrum

increase kVp- increase amplitude

increase kVp- increase # of photons

change in position of graph

99
New cards

increased kVp =

increased photon energies

100
New cards

decreased kVp=

decreased photon energies