1/135
Looks like no tags are added yet.
what x-rays constitute image forming radiation?
x rays that pass through pt WITHOUT interaction
x-rays that are compton scattered IN pt
definition of remnant x-rays
x rays that exit the patient
def of image forming x-rays
x rays that exit pt and interact with IR
def of transmitted x rays
x rays that pass through pt and reach ir without interactions
3 primary factors that influence intensity of scatter radiation that reaches IR
kvp
field size
pt thickness
what is kvp ?
x ray energy
how hard/fast x ray pushes through the body/object
kvp increases what does that do to compton and photoelectric
DECREASES compton and photoelectric
photoelectric decreases faster
is kvp a controllable factor
yes
decrease in kvp does what to image contrast
increases image contrast
so when thinking ONLY about the image quality should you always want low or high kvp, why?
low kvp
better contrast and less scatter
why cant all x rays be set to low kvp? what are the downsides to having low kvp?
more photoelectric absorption which means a higher patient dose
to compensate for low kvp with fewer x rays reaching the IR mas would have to increase
what percentage of INCIDENT x rays in the patient reach the IR
1%
having a larger pt does what to kvp?
INCREASES it
what does more mAs mean in regard to kvp?
MORE PATIENT DOSE
more kvp = ______ scatter and _______ contrast
more scatter
less contrast
when there is more kvp how can contrast be restored?
postprocessing
is field size controlled by the rad tech?
YES YES YES
is pt thickness controlled by the rad tech?
NO NO NO
larger field size = ______ scatter
MORE MORE MORE
more pt thickness = _____ scatter
MORE MORE MORE
less pt thickness = _________ scatter
LESS LESS LESS
how can the tech help improve pt thickness?
COMPRESSION
what modality uses compression?
mammo
how does a compression device improve contrast and reduce pt thickness?
compressing the anatomy brings it closer to the IR , reduces the thickness which reduces the dose
the x ray will lose contrast from
scattered x rays
what is image contrast? - definition 2 parts
visible difference between light and dark areas on image
visual degree difference in signal intensity among soft tissue areas of an image
what is the definition of contrast resolution?
ability to image and distinguish soft tissues
most remnant x rays are
scattered in all directions
remnant x rays are x rays that _____ ___ _____
exit the patient
if you only used transmitted and unscattered x rays the image would be
very sharp
if you only used scatter radiation and NO transmitted x rays that reached the IR the image would be
dull grey and low contrast
what does “change in IR signal corresponding to bone soft tissue interface would be very abrupt” mean?
bone and soft tissue absorb x rays differently and the boundary between the bone and soft tissue creates a sharp edge on the x ray image
what is the most common beam restrictor we talked about in class?
light localizing variable aperature collimator
what is the light localizing variable aperature collimator?
box attached to x ray tube with knobs that allow radiographer to adjust size and shape of light field
what is the focal spot? hint think of flashlight example
specific area on x ray tube anode target where high speed electron beam emitted from cathode strike and produces x rays - crash zone
flashlight- shine flashlight on a playing card the actual focal spot is the light on the card - where the electrons hit in the tube its a metal disk
do all electrons interact on the focal spot?
NO NO NO
off focus radiation defintion
electrons stray from focal spot and interact in other areas
how does off focus radiation affect image contrast and spatial resolution
DECREASES BOTH
how do you control off focus radiation?
collimator
what is the 1st stage entrance collimator?
the collimater has multiple blades that protrude from the top of the collimator into the x ray tube housing
what is the 2nd stage collimator?
this part of the collimator has leaves made of lead 3mm thick that work in pairs and create the rectangle and square beams
simple def - 2nd stage collimator
the leaves that the knobs move
what are the 2nd stage collimator leaves?
the black pieces that the knobs move in the collimator
describe the light localizing variable aperature collimator?
small lamp and mirror
the mirror of the light localizing variable aperature collimator has to be ___________________, why?
on the x ray tube side
so the light can bounce off the mirror and reach the leaves to make the sharp / square light pattern
the lamp and mirror must coincide with . . .
x ray beam
what does pbl stand form?
positive beam limitation
what does pbl mean- what is it?
when you put the IR in the bucky or select a film size on the console adn the light field automatically collimates to that size
should the tech still manually collimate even with the pbl?
YES YES YES
collimator filtration added filtration what does that mean?
added filtration is the physical filter device that is placed between the housing and the collimator
total filtration formula =
inherent filtration + added filtration
scattered x rays does what to image contrast?
DECREASES DECREASES DECREASES
how does beam restriction affect patient dose and image quality
decreases patient dose
increases image quality
what is a radiographic grid?
device that IR is placed in that reduces the amount of scatter to the IR
where is a grid placed?
between the patient and IR
the grid only transmits. . .
x rays that go in a straight line from x ray tube target TO IR
grids
the scattered x rays are
absorbed in the grid material
purpose of the interspace material is
maintain separation between lead strips
what does a grid consist of
-2 things
grids strips
interspace material
what are grid strips?
strips/areas on grid that contain radiopaque material
what is grid interspace material?
areas on grid that contain radiolucent material
construction of a grid- what is the layout with grid strips and interspace material?
grid strips alternate with interspace material
what are common materials that interspace material is made up of? (2)
aluminum or plastic fiber
describe the process of how a grid works
x rays interact and exit the patient
x rays come into contact with grid/grid strips
x rays are absorbed and DONT reach IR
primary beam x rays incident on interspace material are . . .
transmitted to the IR
scattered x rays incident on interspace material
MAY OR MAY NOT be absorbed depending on the angle and characteristics on grid
postpatient absorption of x-rays does what with patient dose when a grid is used
INCREASE INCREASE INCREASE
how much scatter radiation do high quality grids attenuate?
80-90%
grid ratio = (formula)
h/d
grid ratio H=
height of grid
grid ratio T=
thickness of grid strip
grid ratio D=
width of interspace material
3 important dimensions of a grid are
Thickness of grid strip
Height of grid
D- width of interspace material
grid frequency definition
#of grids strips per cm
an increase in grid frequency does what to grid lines on an x ray
DECREASE DECREASE DECREASE
if grid strips are CONSTANT what does that mean for grid frequency and interspace material
INCREASE grid frequency
THINNER interspace
most grids have a frequency of . . .
25-45 lines / cm
how do you find the thickness of 1 line pair
T+D
does mammo have special grids?
YES YES YES
4:1 or 8:1
increase in grid ratio = what to bucky factor
increase bucky factor
increase in bucky factor = does what to technique and pt dose
increase technique
increase pt dose
grid ratio
no grid = ____avg
1
grid ratio
5:1 = ______avg
2
grid ratio
8:1 = ______ avg
4
grid ratio
12:1= _______ avg
5
grid ratio
16:1 = ________ avg
6
when using a grid what do you have to do with technique
increase technique which increases bucky factor
list the grid types
parallel
crossed
focused
moving
virtual
parallel grids are the ________
simplest
parallel grids what are they?
grid where all lead strips are parallel
issue with parallel grids
grid cutoff
what is grid cutoff?
undesirable absorption of primary x rays by grid is partial or complete
grid cutoff is likely to occur when . . .
short SID
large area IR
what types of grids does grid cutoff occur?
ALL OF THEM
what grid is grid cutoff more likely to occur?
parallel grid
distance to grid cutoff =
SID / GRID RATIO
parallel grid
when close to edge of IR
increase in primary x rays
what is a crossed grid?
grid strips are parallel to short and long axis of grid
what is crossed grid made of?
2 parallel grids together
crossed grid ratio
6:1