Imaging CH 15 - objectives

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/135

encourage image

There's no tags or description

Looks like no tags are added yet.

136 Terms

1
New cards

what x-rays constitute image forming radiation?

x rays that pass through pt WITHOUT interaction

x-rays that are compton scattered IN pt

2
New cards

definition of remnant x-rays

x rays that exit the patient

3
New cards

def of image forming x-rays

x rays that exit pt and interact with IR

4
New cards

def of transmitted x rays

x rays that pass through pt and reach ir without interactions

5
New cards

3 primary factors that influence intensity of scatter radiation that reaches IR

kvp

field size

pt thickness

6
New cards

what is kvp ?

x ray energy

how hard/fast x ray pushes through the body/object

7
New cards

kvp increases what does that do to compton and photoelectric

DECREASES compton and photoelectric

photoelectric decreases faster

8
New cards

is kvp a controllable factor

yes

9
New cards

decrease in kvp does what to image contrast

increases image contrast

10
New cards

so when thinking ONLY about the image quality should you always want low or high kvp, why?

low kvp

better contrast and less scatter

11
New cards

why cant all x rays be set to low kvp? what are the downsides to having low kvp?

more photoelectric absorption which means a higher patient dose

to compensate for low kvp with fewer x rays reaching the IR mas would have to increase

12
New cards

what percentage of INCIDENT x rays in the patient reach the IR

1%

13
New cards

having a larger pt does what to kvp?

INCREASES it

14
New cards

what does more mAs mean in regard to kvp?

MORE PATIENT DOSE

15
New cards

more kvp = ______ scatter and _______ contrast

more scatter

less contrast

16
New cards

when there is more kvp how can contrast be restored?

postprocessing

17
New cards

is field size controlled by the rad tech?

YES YES YES

18
New cards

is pt thickness controlled by the rad tech?

NO NO NO

19
New cards

larger field size = ______ scatter

MORE MORE MORE

20
New cards

more pt thickness = _____ scatter

MORE MORE MORE

21
New cards

less pt thickness = _________ scatter

LESS LESS LESS

22
New cards

how can the tech help improve pt thickness?

COMPRESSION

23
New cards

what modality uses compression?

mammo

24
New cards

how does a compression device improve contrast and reduce pt thickness?

compressing the anatomy brings it closer to the IR , reduces the thickness which reduces the dose

25
New cards

the x ray will lose contrast from

scattered x rays

26
New cards

what is image contrast? - definition 2 parts

visible difference between light and dark areas on image

visual degree difference in signal intensity among soft tissue areas of an image

27
New cards

what is the definition of contrast resolution?

ability to image and distinguish soft tissues

28
New cards

most remnant x rays are

scattered in all directions

29
New cards

remnant x rays are x rays that _____ ___ _____

exit the patient

30
New cards

if you only used transmitted and unscattered x rays the image would be

very sharp

31
New cards

if you only used scatter radiation and NO transmitted x rays that reached the IR the image would be

dull grey and low contrast

32
New cards

what does “change in IR signal corresponding to bone soft tissue interface would be very abrupt” mean?

bone and soft tissue absorb x rays differently and the boundary between the bone and soft tissue creates a sharp edge on the x ray image

33
New cards

what is the most common beam restrictor we talked about in class?

light localizing variable aperature collimator

34
New cards

what is the light localizing variable aperature collimator?

box attached to x ray tube with knobs that allow radiographer to adjust size and shape of light field

35
New cards

what is the focal spot? hint think of flashlight example

specific area on x ray tube anode target where high speed electron beam emitted from cathode strike and produces x rays - crash zone


flashlight- shine flashlight on a playing card the actual focal spot is the light on the card - where the electrons hit in the tube its a metal disk

36
New cards

do all electrons interact on the focal spot?

NO NO NO

37
New cards

off focus radiation defintion

electrons stray from focal spot and interact in other areas

38
New cards

how does off focus radiation affect image contrast and spatial resolution

DECREASES BOTH

39
New cards

how do you control off focus radiation?

collimator

40
New cards

what is the 1st stage entrance collimator?

the collimater has multiple blades that protrude from the top of the collimator into the x ray tube housing

41
New cards

what is the 2nd stage collimator?

this part of the collimator has leaves made of lead 3mm thick that work in pairs and create the rectangle and square beams

42
New cards

simple def - 2nd stage collimator

the leaves that the knobs move

43
New cards

what are the 2nd stage collimator leaves?

the black pieces that the knobs move in the collimator

44
New cards

describe the light localizing variable aperature collimator?

small lamp and mirror

45
New cards

the mirror of the light localizing variable aperature collimator has to be ___________________, why?

on the x ray tube side
so the light can bounce off the mirror and reach the leaves to make the sharp / square light pattern

46
New cards

the lamp and mirror must coincide with . . .

x ray beam

47
New cards

what does pbl stand form?

positive beam limitation

48
New cards

what does pbl mean- what is it?

when you put the IR in the bucky or select a film size on the console adn the light field automatically collimates to that size

49
New cards

should the tech still manually collimate even with the pbl?

YES YES YES

50
New cards

collimator filtration added filtration what does that mean?

added filtration is the physical filter device that is placed between the housing and the collimator

51
New cards

total filtration formula =

inherent filtration + added filtration

52
New cards

scattered x rays does what to image contrast?

DECREASES DECREASES DECREASES

53
New cards

how does beam restriction affect patient dose and image quality

decreases patient dose

increases image quality

54
New cards

what is a radiographic grid?

device that IR is placed in that reduces the amount of scatter to the IR

55
New cards

where is a grid placed?

between the patient and IR

56
New cards

the grid only transmits. . .

x rays that go in a straight line from x ray tube target TO IR

57
New cards

grids

the scattered x rays are

absorbed in the grid material

58
New cards

purpose of the interspace material is

maintain separation between lead strips

59
New cards

what does a grid consist of

-2 things

grids strips

interspace material

60
New cards

what are grid strips?

strips/areas on grid that contain radiopaque material

61
New cards

what is grid interspace material?

areas on grid that contain radiolucent material

62
New cards

construction of a grid- what is the layout with grid strips and interspace material?

grid strips alternate with interspace material

63
New cards

what are common materials that interspace material is made up of? (2)

aluminum or plastic fiber

64
New cards

describe the process of how a grid works

x rays interact and exit the patient

x rays come into contact with grid/grid strips

x rays are absorbed and DONT reach IR

65
New cards

primary beam x rays incident on interspace material are . . .

transmitted to the IR

66
New cards

scattered x rays incident on interspace material

MAY OR MAY NOT be absorbed depending on the angle and characteristics on grid

67
New cards

postpatient absorption of x-rays does what with patient dose when a grid is used

INCREASE INCREASE INCREASE

68
New cards

how much scatter radiation do high quality grids attenuate?

80-90%

69
New cards

grid ratio = (formula)

h/d

70
New cards

grid ratio H=

height of grid

71
New cards

grid ratio T=

thickness of grid strip

72
New cards

grid ratio D=

width of interspace material

73
New cards

3 important dimensions of a grid are

Thickness of grid strip
Height of grid
D- width of interspace material

74
New cards

grid frequency definition

#of grids strips per cm

75
New cards

an increase in grid frequency does what to grid lines on an x ray

DECREASE DECREASE DECREASE

76
New cards

if grid strips are CONSTANT what does that mean for grid frequency and interspace material

INCREASE grid frequency

THINNER interspace

77
New cards

most grids have a frequency of . . .

25-45 lines / cm

78
New cards

how do you find the thickness of 1 line pair

T+D

79
New cards

does mammo have special grids?

YES YES YES

4:1 or 8:1

80
New cards

increase in grid ratio = what to bucky factor

increase bucky factor

81
New cards

increase in bucky factor = does what to technique and pt dose

increase technique

increase pt dose

82
New cards

grid ratio

no grid = ____avg

1

83
New cards

grid ratio

5:1 = ______avg

2

84
New cards

grid ratio

8:1 = ______ avg

4

85
New cards

grid ratio

12:1= _______ avg

5

86
New cards

grid ratio

16:1 = ________ avg

6

87
New cards

when using a grid what do you have to do with technique

increase technique which increases bucky factor

88
New cards

list the grid types

parallel

crossed

focused

moving

virtual

89
New cards

parallel grids are the ________

simplest

90
New cards

parallel grids what are they?

grid where all lead strips are parallel

91
New cards

issue with parallel grids

grid cutoff

92
New cards

what is grid cutoff?

undesirable absorption of primary x rays by grid is partial or complete

93
New cards

grid cutoff is likely to occur when . . .

short SID

large area IR

94
New cards

what types of grids does grid cutoff occur?

ALL OF THEM

95
New cards

what grid is grid cutoff more likely to occur?

parallel grid

96
New cards

distance to grid cutoff =

SID / GRID RATIO

97
New cards

parallel grid

when close to edge of IR

increase in primary x rays

98
New cards

what is a crossed grid?

grid strips are parallel to short and long axis of grid

99
New cards

what is crossed grid made of?

2 parallel grids together

100
New cards

crossed grid ratio