Types of Catheters:

  • Over-the-needle catheter

  • Through-the-needle catheter


2
New cards

Respiration:

  • Animals just DON’T ARREST

    • They typically STOP BREATHING & then ARREST


3
New cards

Bradypnea (SLOW breathing) :

  • Caused by:

    • ANESTHETIC DRUGS (MOST COMMON)

    • HYPOTHERMIA (COLD animal causes SLOW respiration)

    • Drugs - can be drug-induced

      • Opioids

      • Propofol

      • Alfaxalone

      • Inhalants

    • Impaired respiratory muscle effort


4
New cards

Tachypnea (FAST breathing):

  • Caused by:

    • TOO LIGHT

    • Hypoxemia (LOW oxygen)

    • Hypotension

    • HYPERTHERMIA (PANT to RELEASE HEAT)

    • ACIDOSIS (PANT off ACID)

    • Pain

    • Opioids

    • Reaction to hypercarbia


5
New cards

Dyspnea and/or Cyanosis:

  • Dyspnea = DIFFICULTY breathing

  • Cyanosis = BLUE MM due to LOW oxygen

    • COMMON to see UNDER anesthesia

  • Caused by:

    • Equipment problems

      • Empty O2 tank

      • Flowmeter turned off

      • Damaged circuit 

    • Airway obstruction

      • ET tube blockage

      • Laryngospasm

      • Aspiration

      • Respiratory disease (pleural effusion, pulmonary edema, diaphragmatic hernia, etc) 

    • EXCESSIVE anesthetic depth


6
New cards

Dyspnea and/or Cyanosis - Actions:

  • CHECK ANIMAL FIRST

  1. Check SpO2 reading

  2. Evaluate other vital signs, anesthetic depth & equipment setup

  3. TURN OFF VAPORIZER - 100% oxygen

  4. Watch for CARDIAC ARREST


7
New cards

Apnea Monitor:

  • One sound for NORMAL BREATHING

  • Different sound for ABSENCE of BREATHING

  • The probe is located between the BREATHING CIRCUIT & the ENDOTRACHEAL TUBE CONNECTOR

  • The LAPSE TIME indicates the TIME in seconds since the PREVIOUS BREATH

    • This alarm is set to sound if the internal between breaths EXCEEDS 10 seconds


8
New cards

Pulse Oximetry:

  • Measures OXYGEN SATURATION

  • LIGHT passes through ARTERIAL BED & MEASURES if the HEMOGLOBIN is SATURATED with OXYGEN


  • Pulse Oximeter Sensors:

  • Plethysmograph:

  • NEEDS to be (OVER) (greater than) > 95%

  • PREFERABLE - (greater than) > 98%


9
New cards

Oxygen Saturation:

  • % of HEMOGLOBIN that carries OXYGEN


10
New cards

Placement - Pulsatile Arterial Bed:

  • Hairless, minimally pigmented area

  • Lip

  • Tongue

  • Pinnae

  • Prepuce

  • Vulva

  • Interdigital space


11
New cards

SPO2 & HR:

  • NEED to MATCH

  • If your HEART RATE DOES NOT match your SPO2 then your SENSOR is INCORRECT

    • Ex:

      • If PULSE OXIMETER is 80 & HR is 100 - it is INCORRECT - NOT matching


12
New cards

Pleth Wave:

  • Pleth wave = the PULSE SIGNAL detected by the PULSE OXIMETER


13
New cards

Pulse Ox Accuracy:

  • NEEDS a PULSATILE arterial bed

    • When would you NOT have one?

      • Faint pulse

      • Cold - Causes vasoconstriction —→ DECREASED blood flow


14
New cards

Inaccurate Pulse Ox:

  • Vasoconstriction

    • HYPOTHERMIA

    • Peripheral vasoconstriction (drugs like Dexmedetomidine)

  • Occlusion of pulsatile arterial bed

  • DARK pigmented skin/tongues

  • Surgery lights

  • Severe anemia

  • Movement

    • Shivering, shaking

  • Hypotension

  • Carbon monoxide poisoning

  • Methemoglobinemia


15
New cards

Capnometry:

  • MEASUREMENT & evaluation of the LEVEL of CO2 in the patients EXHALED BREATH or end-tidal CO2 (ETCO2)

  • ETCO2 = 35-45 mmHG (NORMAL RANGE)


16
New cards

What is CO2?

  • WASTE PRODUCT

  • Breathing exercise


17
New cards

What STIMULATES breathing?

  • CO2 DRIVES RESPIRATION NOT LACK OF O2


18
New cards

Hypoventilation:

  • Breathe TOO SLOWLY or TOO SHALLOWLY

  • If you are NOT ventilating well, you are NOT moving enough CO2 & moving enough OXYGEN

  • If you are HYPOVENTILATING what do you expect your CO2 to do?

    • CO2 INCREASES b/c its NOT being REMOVED from the body

  • ETCO2 = 60 - HYPOVENTILATING

    • HIGH CO2 = HYPOVENTILATING

    • HYPERCAPNIA = HIGH CO2 LEVELS


19
New cards

What can cause HYPERCAPNIA?

  • HYPOVENTILATION

    • Causes EXCESS BUILD UP CO2 - causing HYPERCAPNIA (HIGH CO2 levels)

  • What can cause hypoventilation?

    • Certain drugs

    • COLD

    • TOO DEEP

  • What can cause hypercapnia?

    • Patient factors

      • SLOW respiration

      • SHALLOW respiration

      • Respiratory depression

      • Apnea (temporary stop in breathing)

    • External factors

      • Equipment

        • Expiratory one-way valve (Flutter valves)

        • CO2 absorber exhausted (not absorbing CO2 - cause animal to rebreathe the CO2)

        • Dead space

        • Block in airway 


20
New cards

What is HYPERVENTILATION?

  • Breathing TOO FAST or TOO DEEPLY

  • This “overbreathing” REMOVES TOO MUCH CO2 from the body

  • If you are HYPERVENTILATING what do you expect your CO2 to do?

    • CO2 DECREASES

  • ETCO2 = 25 - HYPERVENTILATING

    • LOW CO2 = HYPERVENTILATING

    • HYPOCAPNIA = LOW CO2 LEVELS


21
New cards

What can cause HYPOCAPNIA?

  • HYPERVENTILATION

    • Can be caused by:

      • PAIN

      • HEAT

      • PANTING (light)

      • Iatrogenic ventilation (ventilator) (we are causing it)

      • Esophageal intubation


22
New cards

What do you expect to happen to the ETCO2 if the animal’s respiration rate is SLOW?

  • HYPOVENTILATION = HYPERCAPNIA (HIGH CO2 LEVELS)


23
New cards

Actions to Take - HYPERCAPNIA:

  • GIVE BREATHS – watch animal’s chest for obstruction or impaired flow

  • Assess anesthetic depth

    • Look at vaporizer setting, consider pre-meds

  • Check CO2 absorber

  • Check machine - Look for EXPIRATORY ONE WAY VALVE - prevents rebreathing CO2

  • Check tube 


24
New cards

What do you expect to happen to the ETCO2 if the animal’s respiration rate is FAST? 

  • HYPERVENTILATION = HYPOCAPNIA (LOW CO2 LEVELS)


25
New cards

Scenario:

  • An animal is HYPERVENTILATING under anesthesia

  • The technicians gives breath, but instead of giving deep breaths, she gives multiple shallow breaths

  • The animal STOPS breathing

  • Why? 

    • HYPERVENTILATION lowers CO2, which REDUCES the STIMULUS to BREATHE


26
New cards

Capnometry Review:

  • HYPERVENTILATION —→ LOW ETCO2 = HYPOCAPNIA

    • Caused by:

      • Feeling PAIN

      • OVERBAGGING (iatrogenic)

      • HYPERTHERMIC (start panting)

      • TOO LIGHT

  • HYPERCAPNIA caused by:

    • EXHAUSTED CO2 absorber

      • Rebreathes the CO2 causing HIGH CO2 levels —→ INSPIRATORY is going to be more than ZERO

    • Stuck EXPIRATORY VALVE —→ INSPIRATORY CO2 will be HIGH

  • HYPOVENTILATION —→ HIGH ETCO2 = HYPERCAPNIA

    • Caused by:

      • BRADYPNEA (TOO SLOW)

      • TOO DEEP

      • TOO COLD

      • Lung damage

      • Certain drugs


  • Propofol & Alfaxalone causes APENA


27
New cards

How do we measure CO2?

  • CAPNOGRAPH


28
New cards

Mainstream vs. Sidestream:

  • Mainstream capnography - CO2 sensor at the ET tube

    • QUICKER

    • ADDS dead space (ventilation WITHOUT gas exchange)

    • Heavy - can pull out tube

EMMA
  • Sidestream capnography - CO2 sample is pulled through tubing to the sensor

    • REMOVES GAS from circuit

    • Problematic with SMALLER patients

    • Moisture from condensation

    • LAG TIME

SAMPLE LINE


29
New cards

Capnographs Patterns:

  • Hypoventilation

    • Gradual INCREASE of ETCO2

    • Causes may include:

      • Narcotic OVERDOSE

      • CNS dysfunction

      • HEAVY SEDATION

  • Hyperventilation

  • Rebreathing

    • Caused by INSPIRED ETCO2 from STUCK expiratory one way valve & FLOW RATE too LOW

  • What should inspired ETCO2 be?

    • SHOULD BE ZERO

  • What can cause an ETCO2 to NOT be ZERO?

    • Malfunctioning one-way valve

    • Exhausted soda lime

    • Fresh gas flow inadequate in a NON-REBREATHING system

  • Leaking tube cuff

    • Possible causes:

      • LEAKY or DEFLATED endotracheal or tracheostomy cuff

      • Artificial airway TOO SMALL for the patient

  • Obstruction in airway or breathing circuit - Shark Fin

    • Possible causes:

      • Partially KINKED or OCCLUDED artificial airway

      • PRESENCE of FOREIGN BODY in the airway

      • OBSTRUCTION in expiratory limb of breathing circuit

      • BRONCHOSPASM

      • ASTHMA


30
New cards

Endotracheal Tube Obstructions:

  • Intraluminal

    • Mucus

    • Blood

    • Gastric contents

    • Airway secretions

    • Teeth, dental implants

    • Granulation tissues

    • Small tubes - mimic partial airway obstruction

  • Extraluminal

    • Kinking

      • Patient positioning

      • Cervical manipulation - especially flexing

    • Compression of tip against tracheal wall

    • Defective tube


31
New cards

What is this capnograph pattern?

  • Sudden apnea

    • Caused by:

      • Disconnection

      • Esophagus intubation

      • Obstruction

  • Exponential decrease

    • Means animal is DYING

  • Hypoventilating

    • Caused by:

      • TOO COLD

      • TOO DEEP


32
New cards

Other Uses of Capnograph Pattern:

  • Use capnometer to confirm endotracheal tube placement & CPR compressions


33
New cards

3 Types of Dead Space:

  • Dead Space= ventilation WITHOUT gas exchange

  • Gas exchange = O2 moves from the LUNGS into the BLOOD & CO2 moves from the BLOOD into the LUNGS to be EXHALED

  • Anatomic

    • UPPER AIRWAY structures that DO NOT participate in GAS EXCHANGE

      • Nasal passages, nasopharynx, larynx, trachea, & in the larger airways = DEAD SPACE

      • Gas exchange happens in the LUNGS - Alveoli

  • Alveolar

    • Represents those ALVEOLI that are VENTILATED with fresh gas but NOT PERFUSED by the PULMONARY CIRCULATION

    • Together, anatomic & alveolar dead space is referred to as PHYSIOLOGIC DEAD SPACE

      • Physiologic dead space gases DO NOT participate in CO2 & O2 exchange

  • Mechanical

    • SPACE in a breathing circuit where BOTH inhalation & exhalation passes through a common path 

      • b/c the patient breathes in & out of the same tube they can possibly inhale some unfiltered exhaled gas (including CO2)

  • FLUID in ALVEOLI (pulmonary edema) can cause DEAD SPACE


34
New cards

Mechanical Dead Space Causes:

  • Endotracheal tube extending BEYOND the patient’s INCISORS

  • Patient monitor adaptors (ETCO2, apnea alert)

  • Any adaptors used to facilitate patient/system positioning (right-angle or swivel adaptors used to reduce the risk of tracheal trauma during patient rotation) 

  • Volume within a mask

  • Humidification management exchangers (HME)

  • “Y” piece (defined as the terminal end of an F circuit or noncircle system & the inhalation/exhalation hose connector in a circle system)

  • EXHAUSTED soda lime or MALFUNCTIONING one-way valves can also contribute to increasing mechanical dead space

  • Mechanical dead space is never ZERO


35
New cards

Total Dead Space:


36
New cards

Reducing Mechanical Dead Space:

  • Most important in animals LESS THAN 6 kg

  • MINIMIZE the number of connectors to the tube

  • Make sure VALVES are NOT “STICKY” & the CO2 ABSORBER is NOT EXHAUSTED

  • Cut ET tube

  • DO NOT use face mask

  • USE PEDIATRIC ADAPTERS when possible


  • Mechanical dead space = CAN be controlled

  • Mechanical dead space causes increased ETCO2


  • Y Circuit

  • Coaxial Circuit

  • Norman Elbow

    • DECREASES MECHANICAL DEAD SPACE


37
New cards

Clinical Example:

  • A dog received propofol & is LIGHT

  • When you attach him to the isoflurane machine he is PANTING

  • After a few minutes he STOPS breathing

  • What do you think is happening here? 

    • Animal is HYPERVENTILATING —→ ETCO2 is DECREASING —→ causing DECREASED respiratory drive —→ stopped breathing b/c the propofol & isoflurane depress the respiratory center in the brain, decreasing respiratory drive & causing apnea (temporary stop breathing)


38
New cards

Lung Abscess - Clinical Example:

  • SURGERY to remove abscess & lung lobes

  • Premed: FENTANYL (opioid - pure mu agonist)

  • Induction: KETAMINE & DIAZEPAM

  • Maintenance: ISOFLURANE

  • Settings for Mechanical ventilation :

    • ETCO2 = 30 & 45 mmHg

    • Respiratory rate of 12 breaths/min 

    • Peak inspiratory pressure < (less than) 10 mmHg


  • 15 minutes after surgery

    • Mechanical ventilator alarm sounded, indicating a pressure abnormality

    • The capnograph wave pattern was not reflecting every ventilator-delivered breath

    • SpO2 had DECREASED to 82%

  • Mechanical Ventilation Discontinued

    • Manual ventilation initiated

    • To obtain a waveform on the capnograph, a peak inspiratory pressure of 20 to 30 mm Hg was required 

    • The expiratory upstroke of the capnograph waveform had a distinct slope

    • Surgeon noted the left lobe inflation was minimal 

  • What do you think is happening here? 

    • Airway OBSTRUCTION, possibly from a KINKED/BLOCKED ET tube or BRONCHOSPASM

    • Animal is HYPOVENTILATING & may have HIGH ETCO2 (HYPERCAPNIA)

  • Continued Manual Ventilation

    • Lungs could not be inflated

    • Cardiac rhythm normal

    • Peak inspiratory pressures as high as 35mmHg

    • No capnograph waveform could be obtained

    • SPO2 = 77%

  • What is the problem?

    • LUNG ABSCESS caused the obstruction - abscess got stuck in the ET tube


39
New cards

Clinical Example:

  • 5-month-old intact female, Yorkshire Terrier mix

  • Presented for elective ovariohysterectomy 

  • Weight = 6.4 kg 

  • Pre med: ACEPROMAZINE (sedative - causes hypotension) & HYDROMORPHONE (opioid - pure mu)

  • Induction: Propofol given to effect 

  • Maintenance: non-rebreathing circuit, isoflurane, oxygen 1L/min 

  • Capnogram:

  • What is the MOST LIKELY cause of the capnogram?

    • LOW FLOW RATE


40
New cards

The normal ETCO2 is:

  • 35-45 mmHg


41
New cards

A pulse oximeter needs all of the following:

  • Hairless area

  • Pulsatile arterial bed

  • A probe with a light

  • EXCEPT: Pigmented skin


42
New cards

A pulse ox can be inaccurate with:

  • Alpha 2 agonist administration


43
New cards

An animal with an ETCO2 of 25 is:

  • Hypocapnic


44
New cards

This picture represents:

  • Patient rebreathing


45
New cards

There are 4 types of dead space:

  • FALSE


46
New cards

In general, HYPERCAPNIA is caused by:

  • Hypoventilation


47
New cards

What drives respiration?

  • CO2


48
New cards

All of the following can cause HYPERCAPNIA:

  • Animal is too deep

  • Stuck expiratory valve

  • Exhausted CO2 absorber

  • EXCEPT: Animal is panting