1/47
Looks like no tags are added yet.
Types of Catheters:
Over-the-needle catheter

Through-the-needle catheter

Respiration:
Animals just DON’T ARREST
They typically STOP BREATHING & then ARREST
Bradypnea (SLOW breathing) :
Caused by:
ANESTHETIC DRUGS (MOST COMMON)
HYPOTHERMIA (COLD animal causes SLOW respiration)
Drugs - can be drug-induced
Opioids
Propofol
Alfaxalone
Inhalants
Impaired respiratory muscle effort
Tachypnea (FAST breathing):
Caused by:
TOO LIGHT
Hypoxemia (LOW oxygen)
Hypotension
HYPERTHERMIA (PANT to RELEASE HEAT)
ACIDOSIS (PANT off ACID)
Pain
Opioids
Reaction to hypercarbia
Dyspnea and/or Cyanosis:
Dyspnea = DIFFICULTY breathing
Cyanosis = BLUE MM due to LOW oxygen
COMMON to see UNDER anesthesia
Caused by:
Equipment problems
Empty O2 tank
Flowmeter turned off
Damaged circuit
Airway obstruction
ET tube blockage
Laryngospasm
Aspiration
Respiratory disease (pleural effusion, pulmonary edema, diaphragmatic hernia, etc)
EXCESSIVE anesthetic depth
Dyspnea and/or Cyanosis - Actions:
CHECK ANIMAL FIRST
Check SpO2 reading
Evaluate other vital signs, anesthetic depth & equipment setup
TURN OFF VAPORIZER - 100% oxygen
Watch for CARDIAC ARREST
Apnea Monitor:
One sound for NORMAL BREATHING
Different sound for ABSENCE of BREATHING

The probe is located between the BREATHING CIRCUIT & the ENDOTRACHEAL TUBE CONNECTOR
The LAPSE TIME indicates the TIME in seconds since the PREVIOUS BREATH
This alarm is set to sound if the internal between breaths EXCEEDS 10 seconds

Pulse Oximetry:
Measures OXYGEN SATURATION
LIGHT passes through ARTERIAL BED & MEASURES if the HEMOGLOBIN is SATURATED with OXYGEN
Pulse Oximeter Sensors:

Plethysmograph:

NEEDS to be (OVER) (greater than) > 95%
PREFERABLE - (greater than) > 98%
Oxygen Saturation:
% of HEMOGLOBIN that carries OXYGEN
Placement - Pulsatile Arterial Bed:
Hairless, minimally pigmented area
Lip
Tongue
Pinnae
Prepuce
Vulva
Interdigital space
SPO2 & HR:
NEED to MATCH
If your HEART RATE DOES NOT match your SPO2 then your SENSOR is INCORRECT
Ex:
If PULSE OXIMETER is 80 & HR is 100 - it is INCORRECT - NOT matching
Pleth Wave:
Pleth wave = the PULSE SIGNAL detected by the PULSE OXIMETER


Pulse Ox Accuracy:
NEEDS a PULSATILE arterial bed
When would you NOT have one?
Faint pulse
Cold - Causes vasoconstriction —→ DECREASED blood flow
Inaccurate Pulse Ox:
Vasoconstriction
HYPOTHERMIA
Peripheral vasoconstriction (drugs like Dexmedetomidine)
Occlusion of pulsatile arterial bed
DARK pigmented skin/tongues
Surgery lights
Severe anemia
Movement
Shivering, shaking
Hypotension
Carbon monoxide poisoning
Methemoglobinemia
Capnometry:
MEASUREMENT & evaluation of the LEVEL of CO2 in the patients EXHALED BREATH or end-tidal CO2 (ETCO2)
ETCO2 = 35-45 mmHG (NORMAL RANGE)
What is CO2?
WASTE PRODUCT
Breathing exercise
What STIMULATES breathing?
CO2 DRIVES RESPIRATION NOT LACK OF O2
Hypoventilation:
Breathe TOO SLOWLY or TOO SHALLOWLY
If you are NOT ventilating well, you are NOT moving enough CO2 & moving enough OXYGEN
If you are HYPOVENTILATING what do you expect your CO2 to do?
CO2 INCREASES b/c its NOT being REMOVED from the body
ETCO2 = 60 - HYPOVENTILATING
HIGH CO2 = HYPOVENTILATING
HYPERCAPNIA = HIGH CO2 LEVELS
What can cause HYPERCAPNIA?
HYPOVENTILATION
Causes EXCESS BUILD UP CO2 - causing HYPERCAPNIA (HIGH CO2 levels)
What can cause hypoventilation?
Certain drugs
COLD
TOO DEEP
What can cause hypercapnia?
Patient factors
SLOW respiration
SHALLOW respiration
Respiratory depression
Apnea (temporary stop in breathing)
External factors
Equipment
Expiratory one-way valve (Flutter valves)
CO2 absorber exhausted (not absorbing CO2 - cause animal to rebreathe the CO2)
Dead space
Block in airway
What is HYPERVENTILATION?
Breathing TOO FAST or TOO DEEPLY
This “overbreathing” REMOVES TOO MUCH CO2 from the body
If you are HYPERVENTILATING what do you expect your CO2 to do?
CO2 DECREASES
ETCO2 = 25 - HYPERVENTILATING
LOW CO2 = HYPERVENTILATING
HYPOCAPNIA = LOW CO2 LEVELS
What can cause HYPOCAPNIA?
HYPERVENTILATION
Can be caused by:
PAIN
HEAT
PANTING (light)
Iatrogenic ventilation (ventilator) (we are causing it)
Esophageal intubation
What do you expect to happen to the ETCO2 if the animal’s respiration rate is SLOW?
HYPOVENTILATION = HYPERCAPNIA (HIGH CO2 LEVELS)
Actions to Take - HYPERCAPNIA:
GIVE BREATHS – watch animal’s chest for obstruction or impaired flow
Assess anesthetic depth
Look at vaporizer setting, consider pre-meds
Check CO2 absorber
Check machine - Look for EXPIRATORY ONE WAY VALVE - prevents rebreathing CO2
Check tube
What do you expect to happen to the ETCO2 if the animal’s respiration rate is FAST?
HYPERVENTILATION = HYPOCAPNIA (LOW CO2 LEVELS)
Scenario:
An animal is HYPERVENTILATING under anesthesia
The technicians gives breath, but instead of giving deep breaths, she gives multiple shallow breaths
The animal STOPS breathing
Why?
HYPERVENTILATION lowers CO2, which REDUCES the STIMULUS to BREATHE
Capnometry Review:
HYPERVENTILATION —→ LOW ETCO2 = HYPOCAPNIA
Caused by:
Feeling PAIN
OVERBAGGING (iatrogenic)
HYPERTHERMIC (start panting)
TOO LIGHT
HYPERCAPNIA caused by:
EXHAUSTED CO2 absorber
Rebreathes the CO2 causing HIGH CO2 levels —→ INSPIRATORY is going to be more than ZERO
Stuck EXPIRATORY VALVE —→ INSPIRATORY CO2 will be HIGH
HYPOVENTILATION —→ HIGH ETCO2 = HYPERCAPNIA
Caused by:
BRADYPNEA (TOO SLOW)
TOO DEEP
TOO COLD
Lung damage
Certain drugs
Propofol & Alfaxalone causes APENA
How do we measure CO2?
CAPNOGRAPH



Mainstream vs. Sidestream:
Mainstream capnography - CO2 sensor at the ET tube
QUICKER
ADDS dead space (ventilation WITHOUT gas exchange)
Heavy - can pull out tube

Sidestream capnography - CO2 sample is pulled through tubing to the sensor
REMOVES GAS from circuit
Problematic with SMALLER patients
Moisture from condensation
LAG TIME

Capnographs Patterns:
Hypoventilation
Gradual INCREASE of ETCO2
Causes may include:
Narcotic OVERDOSE
CNS dysfunction
HEAVY SEDATION

Hyperventilation

Rebreathing
Caused by INSPIRED ETCO2 from STUCK expiratory one way valve & FLOW RATE too LOW

What should inspired ETCO2 be?
SHOULD BE ZERO
What can cause an ETCO2 to NOT be ZERO?
Malfunctioning one-way valve
Exhausted soda lime
Fresh gas flow inadequate in a NON-REBREATHING system
Leaking tube cuff
Possible causes:
LEAKY or DEFLATED endotracheal or tracheostomy cuff
Artificial airway TOO SMALL for the patient

Obstruction in airway or breathing circuit - Shark Fin
Possible causes:
Partially KINKED or OCCLUDED artificial airway
PRESENCE of FOREIGN BODY in the airway
OBSTRUCTION in expiratory limb of breathing circuit
BRONCHOSPASM
ASTHMA

Endotracheal Tube Obstructions:
Intraluminal
Mucus
Blood
Gastric contents
Airway secretions
Teeth, dental implants
Granulation tissues
Small tubes - mimic partial airway obstruction
Extraluminal
Kinking
Patient positioning
Cervical manipulation - especially flexing
Compression of tip against tracheal wall
Defective tube
What is this capnograph pattern?
Sudden apnea
Caused by:
Disconnection
Esophagus intubation
Obstruction

Exponential decrease
Means animal is DYING

Hypoventilating
Caused by:
TOO COLD
TOO DEEP

Other Uses of Capnograph Pattern:
Use capnometer to confirm endotracheal tube placement & CPR compressions
3 Types of Dead Space:
Dead Space= ventilation WITHOUT gas exchange
Gas exchange = O2 moves from the LUNGS into the BLOOD & CO2 moves from the BLOOD into the LUNGS to be EXHALED
Anatomic
UPPER AIRWAY structures that DO NOT participate in GAS EXCHANGE
Nasal passages, nasopharynx, larynx, trachea, & in the larger airways = DEAD SPACE
Gas exchange happens in the LUNGS - Alveoli
Alveolar
Represents those ALVEOLI that are VENTILATED with fresh gas but NOT PERFUSED by the PULMONARY CIRCULATION
Together, anatomic & alveolar dead space is referred to as PHYSIOLOGIC DEAD SPACE
Physiologic dead space gases DO NOT participate in CO2 & O2 exchange
Mechanical
SPACE in a breathing circuit where BOTH inhalation & exhalation passes through a common path
b/c the patient breathes in & out of the same tube they can possibly inhale some unfiltered exhaled gas (including CO2)
FLUID in ALVEOLI (pulmonary edema) can cause DEAD SPACE

Mechanical Dead Space Causes:
Endotracheal tube extending BEYOND the patient’s INCISORS
Patient monitor adaptors (ETCO2, apnea alert)
Any adaptors used to facilitate patient/system positioning (right-angle or swivel adaptors used to reduce the risk of tracheal trauma during patient rotation)
Volume within a mask
Humidification management exchangers (HME)
“Y” piece (defined as the terminal end of an F circuit or noncircle system & the inhalation/exhalation hose connector in a circle system)
EXHAUSTED soda lime or MALFUNCTIONING one-way valves can also contribute to increasing mechanical dead space
Mechanical dead space is never ZERO
Total Dead Space:


Reducing Mechanical Dead Space:
Most important in animals LESS THAN 6 kg
MINIMIZE the number of connectors to the tube
Make sure VALVES are NOT “STICKY” & the CO2 ABSORBER is NOT EXHAUSTED
Cut ET tube
DO NOT use face mask
USE PEDIATRIC ADAPTERS when possible
Mechanical dead space = CAN be controlled
Mechanical dead space causes increased ETCO2
Y Circuit

Coaxial Circuit

Norman Elbow
DECREASES MECHANICAL DEAD SPACE

Clinical Example:
A dog received propofol & is LIGHT
When you attach him to the isoflurane machine he is PANTING
After a few minutes he STOPS breathing
What do you think is happening here?
Animal is HYPERVENTILATING —→ ETCO2 is DECREASING —→ causing DECREASED respiratory drive —→ stopped breathing b/c the propofol & isoflurane depress the respiratory center in the brain, decreasing respiratory drive & causing apnea (temporary stop breathing)
Lung Abscess - Clinical Example:
SURGERY to remove abscess & lung lobes
Premed: FENTANYL (opioid - pure mu agonist)
Induction: KETAMINE & DIAZEPAM
Maintenance: ISOFLURANE
Settings for Mechanical ventilation :
ETCO2 = 30 & 45 mmHg
Respiratory rate of 12 breaths/min
Peak inspiratory pressure < (less than) 10 mmHg
15 minutes after surgery
Mechanical ventilator alarm sounded, indicating a pressure abnormality
The capnograph wave pattern was not reflecting every ventilator-delivered breath
SpO2 had DECREASED to 82%
Mechanical Ventilation Discontinued
Manual ventilation initiated
To obtain a waveform on the capnograph, a peak inspiratory pressure of 20 to 30 mm Hg was required
The expiratory upstroke of the capnograph waveform had a distinct slope
Surgeon noted the left lobe inflation was minimal

What do you think is happening here?
Airway OBSTRUCTION, possibly from a KINKED/BLOCKED ET tube or BRONCHOSPASM
Animal is HYPOVENTILATING & may have HIGH ETCO2 (HYPERCAPNIA)
Continued Manual Ventilation
Lungs could not be inflated
Cardiac rhythm normal
Peak inspiratory pressures as high as 35mmHg
No capnograph waveform could be obtained
SPO2 = 77%
What is the problem?
LUNG ABSCESS caused the obstruction - abscess got stuck in the ET tube
Clinical Example:
5-month-old intact female, Yorkshire Terrier mix
Presented for elective ovariohysterectomy
Weight = 6.4 kg
Pre med: ACEPROMAZINE (sedative - causes hypotension) & HYDROMORPHONE (opioid - pure mu)
Induction: Propofol given to effect
Maintenance: non-rebreathing circuit, isoflurane, oxygen 1L/min
Capnogram:

What is the MOST LIKELY cause of the capnogram?
LOW FLOW RATE
The normal ETCO2 is:
35-45 mmHg
A pulse oximeter needs all of the following:
Hairless area
Pulsatile arterial bed
A probe with a light
EXCEPT: Pigmented skin
A pulse ox can be inaccurate with:
Alpha 2 agonist administration
An animal with an ETCO2 of 25 is:
Hypocapnic
This picture represents:

Patient rebreathing
There are 4 types of dead space:
FALSE
In general, HYPERCAPNIA is caused by:
Hypoventilation
What drives respiration?
CO2
All of the following can cause HYPERCAPNIA:
Animal is too deep
Stuck expiratory valve
Exhausted CO2 absorber
EXCEPT: Animal is panting