1
New cards

Personnel exposure monitoring is required when the worker is likely to receive ____% or more of the annual occupational dose limit.

10

2
New cards

The annual occupational effective dose limit is ___ rem and ___ mSv

5; 50

3
New cards

The personnel monitoring devices protect the radiographer from exposure to ionizing radiation. True or false?

False

4
New cards

The primary dosimeter should be worn ________ and should be worn _____ the apron during fluoroscopy.

at collar level; outside

5
New cards

For fetal monitoring, secondary dosimeter should be worn at the level of the ____ and on the _____ of the apron.

abdomen; inside

6
New cards

If the hands are near the primary beam, a(n) _____ dosimeter should be worn.

TLD ring/extremity dosimeter

7
New cards

Employment records of personnel working in radiation areas should include _____.

dosimeter records/reports

8
New cards

In choosing a dosimeter for personnel to wear, what are the characteristics that the dosimeter should posses?

lightweight, durable, reliable, accurate, and inexpensive

9
New cards

A _____ is used to monitor radiation exposure to dosimeters during transport. This dosimeter must be kept in a _________ area.

control dosimeter/badge; radiation free

10
New cards

Radiation _________ document deep, eye, and shallow exposures. When the dose is below the measurable range for the dosimeter reading period, then the reports will document a(n) letter ______.

personell monitor reports; M (minimal)

11
New cards

The _____ uses aluminum oxide as the detector measuring material.

OSL

12
New cards

When the OSL is read out by a _______, the dosimeter gives off ______ in ____ proportion to the amount of radiation received.

laser light; visible light/luminescence; direct

13
New cards

The OSL can be worn up to _____ year.

one but usually 3 months

14
New cards

The OSL has 3 different filters made of _____, _____, and _____.

aluminum; tin; copper

15
New cards

Once it is readout, the OSL can be ______, but not ______

reanalyzed; reused

16
New cards

What does TLD stand for?

Thermoluminescent Dosimeter

17
New cards

The OSL is sensitive ranging from as low as ______ for x-ray.

1mrem/10 microseiverts

18
New cards

OSL advantages are:

high sensitivity, durable, easy to handle, not affected by heat, can be reread, sensitive to different ranges

19
New cards

OSL disadvantages are:

no immediate readout and can not be reread

20
New cards

The ______ is the most sensitive dosimeter.

pocket ionization/dosimeter

21
New cards

the pocket dosimeter resembles a _________.

fountain pen

22
New cards

The pocket dosimeter is really an _______ chamber and measures _______.

ionization; accumulated exposure

23
New cards

The pocket dosimeter is _________, but it provides _______ readout.

expensive; immediate

24
New cards

The pocket dosimeter must be ________ for accurate readout.

charged

25
New cards

The pocket dosimeter can measure exposures as low as ______.

0mR

26
New cards

Advantages of the pocket dosimeter are:

small, immediate readout, accurate, reusable, and sensitive

27
New cards

Disadvantages of the pocket dosimeter are:

no permanent record, fragile, has to be charged and warmed up

28
New cards

The TLD sensing material is made of _________

lithium fluoride (LIF)

29
New cards

The TLD is _______ in a _______ for the readout process.

heated; TLD analyzer/reader

30
New cards

Once it is readout, the TLD can be _______, but not ______.

reused; re-read

31
New cards

The TLD can measure exposures as low as ______.

5mrem

32
New cards

Advantages of use of the TLD are:

small, reusable, durable, accurate, and cost affective

33
New cards

Disadvantages of use of the TLD are:

no immediate readout, no re-reads

34
New cards

The _________ area survey meter is used to measure exposure rate with fluoroscopic equipment installations.

cutie pie

35
New cards

The ________ area survey meter serves no useful purpose in diagnostic imaging.

proportional counter

36
New cards

The _________ area survey meter is used to detect lost radioactive sources and is used in monitoring nuclear medicine facilities.

geiger-muller detecter (GM)

37
New cards

An ________ is a set of number limits that are based on risks associated with radiation exposure and sets an upper boundary dose that results in negligible risks. These limits have been incorporated into Title _____ of the Code of Federal Regulations, Part ______.

effective dose (EfD) limiting system; 10; 20

38
New cards

NCRP report ______ is the resource basis for the effective dose limiting system.

116

39
New cards

The _____ evaluates radiation biological effects and makes recommendations on an international level.

ICRP

40
New cards

The _____ reviews the ICRP recommendations and incorporates them into the national protection criteria.

NCRP

41
New cards

The _______ and ______ collects data in which the NCRP and ICRP uses to make their dose limit reports.

UNSCEAR; BEIR

42
New cards

The ______ oversees the regulation of the nuclear energy industry.

NRC

43
New cards

The NRC can enter into ________ to assume responsibility for enforcing radiation protection regulation.

Agreement states

44
New cards

The _____ oversees the natural environmental regulation.

EPA

45
New cards

The _____ regulates electronic equipment and particularly the manufacture and installation of radiographic and mammography equipment.

FDA

46
New cards

______ is responsible for regulations concerning an employee’s right to know and workplace hazards.

OSHA

47
New cards

The NRC mandates a Radiation Safety Committee with an ____ overseeing the committee and the facilities radiation protection practices.

RSO

48
New cards

What are the responsibilities of the Radiation Safety Officer?

develops radiation protection program, implements and enforces policies, makes sure of safety

49
New cards

The ______ was passed by Congress in 1968 to protect the public from the hazards of unnecessary radiation exposure from electronic products.

Radiation control for Health and Safety Act of 1968

50
New cards

Major accomplishments by the act were to ensure that subsequent exposures of the exact same technical factors produce the same output… this is called _______. Also the act ensured that varied ma and time combinations that yielded the same mAs had consistent output is called _______.

reproducibility; linearity

51
New cards

The act incorporated automatic collimation which is called ________.

Positive Beam Limitation (PBL)

52
New cards

It also called for ____________ backup times when using Automatic Exposure Control.

manual

53
New cards

Indicators for beam on must be ______ and ______.

audible; visible

54
New cards

The _________ required minimal standards for educational program accreditation in radiography.

consumer-pt radiation Health and Safety Act of 1981

55
New cards

Effects that are random are considered _________. The radiation protection philosophy are based on these effects.

Stochastic (probabilistic) (non-threshold) effects

56
New cards

Effects that are based on threshold doses are considered ___________.

deterministic (non stochastic) effects

57
New cards

Stochastic effects are considered to be _________.

non threshold

58
New cards

Nonstochastic effects are considered to be _______.

threshold

59
New cards

What is the ALARA principle?

As Low As Reasonably Achievable

60
New cards

The tissue weighing factor indicated the _______ of the organs to radiation exposure. The ______ are the most sensitive organs.

radiosensitivity; gonads

61
New cards

List dose limits for the following:

  1. Annual occupational

  2. Public exposures frequent

  3. Public exposures infrequent

  4. Embryo fetus exposures

  5. Education and training purposes


  1. 50mSv

  2. 1mSv

  3. 5mSv

  4. 0.5mSv

  5. 1mSv


62
New cards

Calculate cumulative effective dose for a radiation worker who is 40 years old.

400mS / 40REM

63
New cards

Calculate collective effective dose for 100 people exposed to an average EfD of 50 Sv.

5000 person/sievert