What is the purpose of TLC?
To separate and identify components in a mixture and check whether a reaction is complete.
What are the two phases in TLC?
The stationary phase (silica gel) and the mobile phase (the solvent).
What is the stationary phase in normal-phase TLC?
Silica gel, which is polar.
What is the mobile phase in TLC?
The solvent that travels up the TLC plate, such as ethyl acetate and hexanes.
Why is silica gel considered polar?
It has polar Si-O bonds and surface OH groups that interact with polar molecules.
What does Rf stand for?
Retention factor. It describes how far a compound travels compared with the solvent front.
What is the formula for Rf?
Rf = distance traveled by the compound spot ÷ distance traveled by the solvent front.
Does Rf have units?
No. Rf is a ratio, so it has no units.
If a compound travels 2 cm and the solvent front travels 5 cm, what is its Rf?
0.40 (2 ÷ 5 = 0.40).
What does a high Rf value mean?
The compound traveled farther up the plate and generally interacts less strongly with polar silica.
What does a low Rf value mean?
The compound traveled a shorter distance and generally interacts more strongly with polar silica.
Which usually travels farther on a silica TLC plate: a polar or nonpolar compound?
A less polar compound usually travels farther because it interacts less strongly with the polar silica.
Why do polar compounds have lower Rf values on silica?
They interact strongly with the polar silica and are held back instead of traveling with the solvent.
Why do nonpolar compounds have higher Rf values on silica?
They interact less strongly with silica and travel farther with the mobile phase.
What happens if the TLC solvent is too nonpolar?
The compounds may barely move and remain close to the baseline.
What happens if the TLC solvent is too polar?
The compounds may travel too far, close to the solvent front, making separation difficult.
What happens when you increase the amount of ethyl acetate in a hexanes/ethyl acetate solvent mixture?
The mobile phase becomes more polar, so compounds generally travel farther up the TLC plate.
What happens when you increase the amount of hexanes?
The mobile phase becomes less polar, so compounds generally travel less far.
What does one spot on a TLC plate usually suggest?
The sample may contain one major component, suggesting it is relatively pure.
What do multiple spots on a TLC plate suggest?
The sample may contain multiple compounds, impurities, or unreacted starting material.
Can two different compounds have the same Rf value?
Yes. TLC alone cannot prove that two compounds are identical.
Why should the solvent level stay below the TLC baseline?
If the baseline is submerged, the sample can dissolve into the solvent instead of traveling up the plate.
Why do you mark the solvent front immediately after removing a TLC plate?
The solvent evaporates, so the front becomes difficult to see.
What does it mean if the starting material spot disappears after a reaction?
It suggests the starting material may have been used up, although TLC alone cannot prove the reaction is complete.
What is the relationship between polarity and Rf on a normal-phase silica TLC plate?
More polar compounds generally have lower Rf values; less polar compounds generally have higher Rf values.
What is the purpose of liquid-liquid extraction?
To separate compounds based on how well they dissolve in two different liquid layers.
What does immiscible mean?
Two liquids that do not mix and instead form separate layers.
What are two common immiscible liquids used in extraction?
Water and an organic solvent, such as ethyl acetate.
What determines which layer is on top during extraction?
The densities of the two liquids.
Which layer is on the bottom?
The denser liquid.
Which layer is on the top?
The less dense liquid.
What does "like dissolves like" mean?
Polar substances generally dissolve in polar solvents, while nonpolar substances generally dissolve in nonpolar solvents.
Where do ionic compounds usually dissolve best?
In the aqueous (water) layer because water is polar.
Where do many neutral organic compounds dissolve best?
In the organic layer, depending on their polarity.
What is the purpose of a separatory funnel?
To mix two immiscible liquids and then separate the layers.
Why do you vent a separatory funnel?
To release pressure that may build up from gases or vapors.
What happens when sodium hydroxide (NaOH) is added to benzoic acid?
NaOH removes the acidic hydrogen and converts benzoic acid into ionic sodium benzoate.
Why does sodium benzoate move into the aqueous layer?
It is ionic and dissolves much better in polar water.
How can sodium benzoate be converted back into benzoic acid?
Add acid, such as HCl, to protonate the benzoate ion.
Why does benzoic acid precipitate after acid is added?
It becomes neutral and is less soluble in water.
What is the purpose of acid-base extraction?
To change a compound's charge so that it moves between the aqueous and organic layers.
What is the difference between benzoic acid and sodium benzoate in extraction?
Benzoic acid is neutral and less water-soluble; sodium benzoate is ionic and more water-soluble.
If a compound is charged, which layer will it usually prefer?
The aqueous layer.
If a compound is neutral and nonpolar, which layer will it usually prefer?
The organic layer.
Why is density important when collecting extraction layers?
It helps you identify which layer contains the desired compound.
Does the organic layer always sit on top?
No. Its position depends on the organic solvent's density compared with water.
What is the purpose of column chromatography?
To separate and collect individual compounds from a mixture.
What is the stationary phase in column chromatography?
Silica gel, which is polar.
What is the mobile phase in column chromatography?
The solvent that flows through the column.
How is column chromatography similar to TLC?
Both commonly use polar silica as the stationary phase and separate compounds based on polarity.
How is column chromatography different from TLC?
In TLC, solvent moves up a plate; in column chromatography, solvent moves down through a column.
Which compound usually comes out of a silica column first: polar or nonpolar?
The less polar compound.
Why does the less polar compound come out first?
It interacts less strongly with silica, so the solvent carries it through the column more easily.
Why does the more polar compound come out later?
It interacts more strongly with silica and takes longer to travel through the column.
What does elute mean?
To travel through and come out of the chromatography column.
What is a fraction in column chromatography?
A collected portion of liquid that comes out of the column.
Why are fractions collected in separate test tubes?
To keep the separated compounds from mixing together.
Why is TLC used to analyze column fractions?
To determine which compounds are present in each fraction.
What does one spot on a fraction's TLC plate suggest?
The fraction may contain one major compound.
What do multiple spots on a fraction's TLC plate suggest?
The fraction contains more than one compound.
In the fluorene and fluorenone separation, which compound elutes first?
Fluorene, because it is less polar.
Why is fluorenone more polar than fluorene?
Fluorenone contains a carbonyl (C=O) group, which makes it more polar.
What happens if you increase the amount of ethyl acetate in the column solvent?
The solvent becomes more polar and generally moves compounds through the column faster.
What happens if you use more hexanes in the column solvent?
The solvent becomes less polar and compounds generally move through the column more slowly.
What is the relationship between TLC Rf and column elution order?
Under comparable solvent conditions, a higher-Rf compound generally elutes from the column first.
Why might a very polar compound remain near the top of a silica column?
It interacts strongly with the polar silica and may need a more polar solvent to move.