1/119
Looks like no tags are added yet.

Define Boyle’s Law
The pressure of a gas ↑ as its volume ↓
& vice versa
assuming pressure has a constant
mass
temperature
pulling up will ↑ volume and ↓ pressure
pushing down will ↓ volume and ↑ pressure
equation
P1V1 = P2V2
Define external respiration
Exchange of O2 and CO2 between
alveoli and pulmonary capillaries
gas exchange at alveolar level
interacts w/ breath

Define internal respiration
Movement of O2 from
systemic blood into cells
removal of CO2 (tissues to bloodstream)
used for oxidation to produce energy → CO2 major by-product of aerobic metabolism

Intrapleural pressure is _____ (negative or positive?) relative to atmosphere.
negative
Convert mmHg to cmH2O and vice versa
1 mmHg = 1.36 cmH₂O
1 atm = 760 mmHg = 1034 cmH₂O
mmHg -> cmH2O: multiply by 1.36.
cmH2O -> mmHg: divide by 1.36.
ex: converstions for mmHg and cmH2O
mmHg → cmH2O
cmH2O → 26
mmHg → cmH2O ( multiple by 1.36)
ex: 26 mmHg → (26 × 1.36)= 35.36 cmH2O
cmH2O → 26 cmH2O (divide by 1.36)
ex: 26 cmH2O → (26 / 1.36) = 19.12
What is the relationship between Earth atmosphere and positive pressure measurement in mechanical ventilation
At rest, alveolar pressure = atmospheric pressure = 0 → no gas flow.
equations for Pta, Ptt, Ptr, Ptp
PTA = PIP – Pplat
PTA = Pawo – Palv
Transairway pressure
PTT = Palv – Pbs
Transthoracic pressure
PTR=PTA+PTT or PTR= Pawo−Pbs
Transrespiratory pressure
PTP= Palv - Ppl
Transpulmonary pressure
*note: plat pressure can also be used for Palv
Define transairway pressures (PTA)
PTA = PIP – Pplat
PTA = Pawo – Palv (on vent)
Pressure difference between the
airway opening & the alveolus
The pressure required to
overcome airway resistance
Define transthoracic pressures (PTT)
PTT = Palv – Pbs
This pressure gradient is the difference between
the alveolar space
the pressure at the body surface.
It’s the pressure required to expand
the lungs AND chest wall together

Define transrespiratory pressure (PTR)
PTR=PTA + PTT
PTR= Pawo − Pbs
PTR= PIP−Pplat
pressure used to overcome airway resistance
Pplat = pressure remaining when flow stops—reflecting elastic load
Pressure across the entire respiratory system
During positive-pressure ventilation, PTR is the total pressure required to move air through
the airways
and expand the lungs and chest wall.
“the whole burrito”
Define transpulmonary pressures (PTP)
PTP= Palv - Ppl
also known as
alveolar distending pressure
keeps the alveoli/lungs open
the difference between
alveolar pressure
pleural pressure
Sometimes Plateau pressure is used instead of Palv
Define elastance
the tendency of the lungs to return to their original shape after being stretched
resist stretching or expansion
reflects the lungs’ resistance to stretching
↑ Elastance = ↓ Compliance (stiff lungs, harder to inflate)
↓ Elastance = ↑ Compliance (lungs stretch more easily)
E= ΔP / ΔV
opposite of compliance
Define compliance
compliance is the:
Ease of Expansion (lungs)
Units:
mL/cmH₂O
C= ΔV / ΔP
high vs. low compliance
High compliance
more volume produced by less pressure
Low compliance
more pressure required to produce same volume
stiff respiratory system
Define resistance
resistance is the opposition to flow
units
cmH2O/L/sec
Raw = PTA / Flow
Raw = (PIP – Pplat) / Flow
Know how to calculate dynamic compliance
Cdyn= (Vte) / (PIP−PEEP)
units of mL/cmH₂O
Affected by
compliance
Raw
extra pressure is required to overcome airway resistance during gas flow
* Accurate measurement requires a passive patient
spontaneous effort can distort the result
𝐶𝑑𝑦𝑛 ≤ Cstat always
Know how to calculate static compliance
know normal value
Cstat=(Vte) / (Pplat−PEEP)
units of mL/cmH₂O
Reflects the elastic properties of the lungs and chest wall.
normal range
40-50 to 100 mL/cmH2O male
35-45 to 100 mL/cmH2O female
Low Values (< 20 mL/cmH₂O): Indicate stiff lungs or decreased elasticity
seen in
pulmonary fibrosis
PNA
pulmonary edema
ARDS

Know how to calculate airway resistance
convert min → sec (divide by 60)
Raw = (PIP – Pplat) / Flow
Raw = PTA / Flow
units of cmH2O/ L / Sec
the higher it is the more airway resistance there is
Explain how changes in lung compliance affect the peak pressure
↓ compliance
↑PIP ↑Plat
good compliance
↓PIP ↓Plat
↑ Raw (airway resistance)
↑PIP
bigger PIP to plat difference
plat stays the same
↓ Raw (airway resistance)
smaller PIP to plat difference
OR normal
Describe the changes in airway conditions that can lead to increased resistance
Bronchospasm
Airway or mucosal edema
Secretions
Small, long, bitten, or kinked ETT
Higher inspiratory flow
Bedside clue: PIP rises while Pplat remains
unchanged.
Define PIP
Highest airway pressure reached during inspiration
PIP is the pressure needed to
overcome airway resistance.
to move gas
expand the lungs and chest wall.
expand the respiratory system
Includes resistive pressure + elastic pressure + PEEP
Define Plat
alveolar pressure
reflects respiratory system compliance
no gas flow = no resistive pressure
measured during inspiratory hold
Define PEEP
baseline pressure is positive; commonly 5 cmH₂O’
the baseline pressure maintained in the lungs at the end of exhalation
Helps keep the alveoli open
NIV:
PEEP
CPAP
prevent
airway closure
alveolar collapse at end of expiration
They do that by ↑ patient’s FRC
This leads to better
oxygenation
What is PEEPe (extrinsic PEEP)?
PEEP deliberately set by RT on ventilator
The baseline pressure programmed into and delivered by a mechanical ventilator
Does not eliminate trapped gas
can counterbalance part of the PEEPi (autoPEEP)
common target: approx 80% of measured TOTAL peep
What is PEEPi (intrinsic PEEP)?
autoPEEP - pressure remaining in the lungs because of incomplete exhalation/air trapping
Time constant: calculation
Time Constant =Raw x Compliance
1 time constant = 63%
2 = 86%
3 = 95%
Allow at least 3 time constants for approx. 95% emptying; pts with obstruction may require 4-5 time constants to minimize
air trapping
autoPEEP
4 = 98%
5 = 99%

Time constant: application
Individual lung units vary in compliance and resistance
Unequal time constants cause uneven distribution of ventilation
Question: Two lung units have the same resistance. One has normal compliance; the other is stiff.
Which fills faster—and which receives less volume?
The stiff unit has the shorter time constant and fills faster, but it receives less volume for the same pressure.
stiff lungs:
ILD
ARDS

short time constant
fills and empties quickly
ARDS
PULMONARY FIBROSIS
ADVANCED ILD
restrictive diseases
low compliance → shorter time constants
These stiff lung units
reach equilibrium quickly
receive relatively little volume for a given pressure.
long time constant
fills and empties slowly
obstructive diseases
COPD
asthma
emphysema
Slow lung units → long time constants
Time constant: clinical significance in obstructive disease
Long time constant: fills and empties slowly
obstructive diseases
COPD
COPD:
↑ resistance + potentially ↑ compliance
Apply equation of motion to relative work of breathing for patient vs vent
Pmus + Pvent = Palv + PTA
Pmus
In a spontaneous mode, patient rules the day
Patient is breathing with minimal support. PATIENT does MOST of the work
can do most work when
The patient has had sedatives lifted or completely turned off. The patient is able to spontaneously breathe with minimal support. ex. CPAP+PS
Pvent
In a controlled mode on heavy medication or paralytics
Patient on heavy dose or fentanyl of and versed so VENTILATOR does most, if not all, of the work
Describe pressure and volume delivery in volume-controlled breaths
constant:
Flow & volume
variable
pressure
square waveform
Guaranteed VE (min vol)
Can have barotrauma if pressure is not well controlled by alarms settings

Describe pressure and volume delivery in pressure-controlled breaths
constant/fixed :
pressure
variable
Flow, flow varies
decelerating ramp
MAP is higher, can lead to better oxygenation
Can lead to volutrauma if not well controlled by tight alarms settings

Constant vs descending/decelerating flow pattern
Constant Flow Pattern
Constant flow pattern ok with normal lung patients
Reduces MAP (Mean Airway Pressure) but MAY NOT be useful for a patient with severe hypotension and cardiac instability
Descending Ramp Flow Pattern
Improves gas distribution
May increase oxygenation by INCREASING MAP
Decrease PIP
Often useful with DECREASED compliance and hypoxemia
Explain the difference of mandatory, assisted, and spontaneous breaths in these modes: AC/VC, AC/PC, SIMV/VC w/PS, SIMV/PC w/PS, PS/CPAP, PRVC
AC/VC: Mandatory breaths are ventilator-triggered and deliver a set VT. Assisted breaths are patient-triggered and receive the same set VT. No independent spontaneous breaths.
AC/PC: Mandatory breaths are ventilator-triggered and deliver a set inspiratory pressure and time. Assisted breaths are patient-triggered and receive the same pressure and inspiratory time. No independent spontaneous breaths.
SIMV/VC w/PS: Mandatory breaths are ventilator-triggered and deliver a set VT. Assisted mandatory breaths are patient-triggered and deliver the set VT. Spontaneous breaths occur between mandatory breaths and receive pressure support.
SIMV/PC w/PS: Mandatory breaths are ventilator-triggered and deliver a set inspiratory pressure and time. Assisted mandatory breaths are patient-triggered and receive the same pressure and time. Spontaneous breaths occur between mandatory breaths and receive pressure support.
PS/CPAP: No mandatory or assisted mandatory breaths. All breaths are spontaneous and patient triggered. PS assists inspiration, while CPAP maintains positive airway pressure.
PRVC: AC-PRVC, mandatory breaths are ventilator-triggered, and assisted mandatory breaths are patient-triggered. The ventilator automatically adjusts inspiratory pressure to achieve a target VT. No independent spontaneous breaths in AC-PRVC.
Know the 4 variables: pressure, volume, flow, time
pressure-controlled breathing
pressure remains constant
volume/flow vary
volume-controlled breathing
volume and flow remain constant
pressure varies
flow-controlled breathing
flow and volume remain constant
pressures vary
required LEAST WOB (trigger)
Time-controlled breathing
isn’t used much
high-frequency jet ventilators (neonatal) and a few others
Name the two most commonly used patient-trigger variables
Need to set Sensitivity, also known as patient effort
This should be set either as pressure triggering, flow triggering
flow
more common than pressure sensitivity
flow tends to requires less WOB than pressure sensitivity triggers
when vent detects a drop of flow in patient circuit during exhalation
sensitivity
If flow sensitivity is set high, it requires more patient effort
If flow sensitivity is set low, it requires less patient effort
If flow sensitivity is set too low, vent will auto-trigger
If flow sensitivity is set too high, patient will be locked out
-1 to -2 cmH2O common for pressure sensitivity setting
Triggering sensitivity
insensitive: delayed or missed breaths, increased WOB
too sensitive: auto-triggering
Breaths can be triggered by either _____ or by the ____.
time, patient
identify which patient trigger requires the least work of breathing
flow tends to requires less WOB than pressure sensitivity triggers
Flow rate: How quickly does the patient receive the breath?
Flow pattern: How is that flow distributed throughout inspiration?
Higher flow:
Shorter Ti, longer Te
Helps meet high inspiratory demand
Useful when more exhalation time is needed
Lower flow:
Longer Ti, shorter Te
May improve gas distribution
Can be problematic if the patient needs more inspiratory flow
TLC: trigger
be able to define and understand how it work in mechanical ventilation
How inspiration begins
Breath can be triggered by:
TIME
PATIENT
VOLUME
Manual (by RT)
TLC: limit
be able to define and understand how it work in mechanical ventilation
A limit places a maximum on a variable.
Do limits end inspiration?
NO, they only limit how much or how long something goes on for.
What does it mean when the limit variable is PRESSURE?
What are some examples of modes that are pressure-limited?
A maximum pressure allowed is set by the RT.
AC/PC = pressure setting
VC modes = high pressure alarm setting
PS/CPAP = pressure support setting
What does it mean when the limit variable is FLOW?
What’s the difference between older vs modern ICU vents that are flow-limited?
a maximum flow is set by the RT.
Older vents: pt cannot exceed set flow
Modern ICU vents: Usually allow additional flow
TLC: cycle
be able to define and understand how it work in mechanical ventilation
how the vent ends inspiration
the way inspiration ends.
Time cycling: Inspiration ends when the set Ti has elapsed.
Flow cycling: Inspiration ends when flow falls to a preset percentage of peak inspiratory flow.
Pressure cycling: Inspiration ends when a preset pressure is reached.
Volume cycling: Inspiration ends when a preset volume is delivered. Your slides note that modern ICU ventilators are generally not truly volume-cycled.
AC/VC: Time-cycled.
AC/PC: Time-cycled.
Pressure support (PS): Flow-cycled.
Bird Mark 7: Pressure-cycled.
At that time, the expiratory valve open and exhaled air is vented out
Vt = flow x Ti
time cycling
time-cycled ventilation
A breath is time cycled if the inspiratory phase ends when a predetermined time has elapsed
AC/VC
The Ti set by the RT has elapsed.
ex. AC/VC Ti = 1.1 sec
After 1.1 sec, inspiration ends.
volume-controlled
time cycled
because breath ends after Ti ends and VC = Volume Control(led)
With time-cycled, volume-controlled
ventilation, increases and decreases in
compliance do not impact flow pattern or
volume.
Volume is delivered in a fixed
amount of time.
Pressure can vary with
each breath.
AC/PC
With time-cycled, pressure-controlled
ventilation
volume and flow vary.
If compliance goes up or down, flow and volume change. AC/PC limits pressure and cycles with time. This mode can be used to protect the lungs from high pressures. Alarms must be set carefully to make sure patient gets adequate minute ventilation
PC
PRVC
Understand flow cycling and which modes use it
With flow-cycled ventilation, the vent cycles into the expiratory phase once
flow reaches predetermined value during inspiration.
Flow cycling is the most common cycling mechanism
When the flow reaches a percentage of peak inspiratory flow, exhalation begins, usually 5 – 80%
Inspiratory flow falls to a preset percentage of peak flow.
Common setting: 25-50%
In flow-cycled breaths, what does it mean to cycle at 20%?
To cycle at 20% means the vent ENDS inspiration when inspiratory flow decreases to 20% of its peak flow.
The ventilator waits for insp flow to decrease to a lower % of its peak flow before ending inspiration.
examples:
PS
VS
SIMV (spontaneous breaths are flow-cycled)
How does a lower set Esens (expiratory trigger sensitivity, or ETS) affect Ti?
lower Esens % → longer the Ti.
Inflation (inspiratory) hold and how it impacts inspiratory time
also called:
inspiratory hold
end inspiratory pause
This inspiratory hold is designed to keep air in the lungs at the end of inhalation, before exhalation valve opens
Sometimes, this technique is used to
↑ peripheral distribution of gas and improve oxygenation
may improve oxygenation
But if you ↑ i-time, you also ↓ e-time
measures:
pplat
That is, there’s no free lunch…
Baseline pressure definition
also known as:
baseline variable
The baseline variable is the parameter that is
controlled during exhalation
It could use volume or flow, but it’s usually set with PRESSURE
If pressure is > 0 cmH2O, then it’s PEEP
expiratory retard
one way to simulate ‘pursed lip’ breathing on the vent is with something called an expiratory retard.
This technique isn’t used as much today like before, but realize that expiratory valves & bacterial filters produce resistance to flow and create some of the ‘pursed lip’ breathing effect
Keeps airways open longer during exhalation in pts with obstruction; old technique rarely used today
Pt has to overcome autoPEEP before reaching the trigger threshold.
(ex. 9 cmH2O of autoPEEP present + - 2 cmH2O pressure trigger = 11 cmH2O insp effort required to trigger)
expiratory hold; does this measures autoPEEP?
Expiratory hold or end-expiratory pause delays the next inspiration
To get an accurate value, patient should not be actively breathing
Expiratory hold used to measure the auto-PEEP or unplanned PEEP
pt must be passive
no active/spontaenous breathes
Tells how much air is trapped in the lungs at the end of exhalation
Pause at end-expiration
Define acute respiratory failure (ARF) Type I
also called Acute hypoxemic respiratory failure
Life-threatening or vital organ-threatening tissue hypoxia.
The lungs cannot adequately oxygenate the blood, resulting in low arterial oxygen levels.
May be treated with CPAP/PEEP, but invasive ventilation may be required when hypoxemia occurs with ↑ WOB and/or hypercapneic respiratory failure.
ARF I critical values - (oxygenation)
PaO2
A-a gradient
PaO2/PAO2
P/F ratio
PaO2:
< 70 mmHg when FiO2 > 60%
A-a gradient:
>450 mmHg when on O2
PaO2/PAO2:
< 0.15
P/F ratio:
< 200
Define acute respiratory failure (ARF) Type II
Acute hypercapnic respiratory failure
Inability to maintain normal PaCO₂ due to ventilatory pump failure
The lungs cannot adequately eliminate carbon dioxide due to insufficient alveolar ventilation, resulting in CO₂ retention.
CNS disorders:
drug overdose
stroke
sleep apnea syndrome
Neuromuscular disorders:
paralytics
paralytic disorders (myasthenia gravis, tetanus, botulism, polio, Guillain-Barre syndrome, ALS, muscular dystrophy (MD)
CRITICAL VALUES: pH < 7.25 *** PaCO2 55 mmHg and rising Vd/Vt ratio > 0.6
ARF II critical values -
pH
PCO2
Vd/Vt ratio
pH: <7.25
PCO2: 55 mmHg and rising
Vd/Vt ratio > 0.6
Know the list of indications for mechanical ventilation (Box 4-6 in the text)
ARF Type I, ARF Type II, and inability to protect the airway are
the 3 primary reasons to initiate mechanical ventilation.
Apnea or impending respiratory arrest
Acute COPD exacerbation w/ dypnea, tachypnea, and acute respiratory acidosis plus at least one of:
acute cardiovascular instability,
altered mental status
inability to protect lower airway
copious/viscous secretions
facial/upper airway abnormalities preventing NIV
Neuromuscular disease causing acute ventilatory insufficiency accompanied by any of:
acute resp. acidosis
progressive decline in
VC to 10-15 mL/kg
MIP to below -20 to -30 cmH2O
Acute hypoxemic resp failure with tachypnea, resp distress, and persistent hypoxemia despite administration of a high FiO2 or in the presence of:
acute cardiovascular instability
altered mental status inability to protect airway
altered mental status, persistent uncooperativeness
Need for ET intubation to maintain or protect airway or manage secretions, given the following:
ETT < or = 7 mm ID w/ Ve > 10 L/min
ETT < or = 8 mm ID w/ Ve > 15 L/min
Identify 8 objectives of mechanical ventilation
Reverse
acute respiratory failure (ARF)
respiratory distress
respiratory muscle fatigue
hypoxemia
Reduce
systemic or myocardial oxygen consumption
mortality and associated complications of M.V
Prevent or reverse atelectasis, maintain FRC
Permit sedation or paralysis (or both)
Utilize signs of respiratory distress to determine if pt requires invasive mechanical ventilation
Step 1: If the patient can be awakened, how responsive are they?
Step 2: Are nail beds cyanotic? Is the patient pale or diaphoretic?
Step 3: Assess VS: RR, pulse, BP, temp, oxygenation status
***Note: Sudden onset of dyspnea accompanied by physical signs of distress***Look for signs of anxiety, such as furrowed eyebrow, flared nostrils, uncomfortable posture, etc.
Should the patient go on NIV?
Should the patient titrate to higher FiO₂?
Does the patient need to be intubated?
Identify signs of respiratory distress
anxious appearance
Ashen, pale or cyanotic
Accessory muscle use
Abnormal BS
Flared nostrils
Flushed
Tripoding
Tachycardia, hypotension, arrhythmias
Diaphoretic
Retractions
Describe four categories of disorders that may lead to ARF
Central Nervous System (CNS) Disorders
- Drug overdose (opioids, sedatives)
- Brain injury
- Stroke
- Depressed respiratory drive
Neuromuscular Disorders
- Guillain-Barré syndrome
- Myasthenia gravis
- Spinal cord injury
- Respiratory muscle weakness
Chest Wall Disorders
- Flail chest
- Severe kyphoscoliosis
- Chest trauma
- Restricted chest expansion
Pulmonary (Lung) Disorders
- COPD exacerbation
- Asthma
- Pneumonia
- ARDS
- Pulmonary edema
CNS disorders that cause REDUCED drive to breathe, potentially leading to ARF? (4)
(Pilbeam Ch. 4 box 4.2)
Depressant drugs (barbiturates, tranquilizers, narcotics, general anesthetics)
Brain or brainstem lesions (stroke, head/neck trauma, cerebral hemorrhage, tumors, spinal cord injury)
Hypothyroidism
Sleep apnea syndrome caused by idiopathic central alveolar hypoventilation
CNS disorders that cause INCREASED drive to breathe, potentially leading to ARF? (3)
(Pilbeam Ch. 4 box 4.2)
Increased metabolic rate (increased CO2 production)
Metabolic acidosis
Anxiety associated with dyspnea
What are some disorders that increase the WOB, potentially leading to ARF? (8)
Pleura-occupying lesions (e.g., pleural effusions, hemothorax, empyema, pneumothorax)
Chest wall deformities (e.g., flail chest, rib fracture, kyphosco-liosis, obesity)
Increased airway resistance resulting from increased secretions, mucosal edema, bronchoconstriction, airway inflamma-tion, or foreign body aspiration (e.g., asthma, emphysema, chronic bronchitis, croup, acute epiglottitis, acute bronchitis
Lung tissue involvement (e.g., interstitial pulmonary fibrotic diseases, aspiration, acute respiratory distress syndrome, cardiogenic pulmonary edema, drug-induced pulmonary
Pulmonary vascular problems (e.g., pulmonary thromboem-bolism, pulmonary vascular damage)
Other problems (eg., increased metabolic rates with accompanying pulmonary problems)
Postoperative pulmonary complications
Dynamic hyperinflation (air trapping)
What are some neuromuscular disorders that may lead to ARF? (4)
(Pilbeam Ch. 4 box 4.2)
Paralytic disorders (myasthenia gravis, tetanus, botulism, guillan barre, muscular dystrophy)
Paralytic drugs (curare, nerve gas, succinylcholine, insecticides, non-depolarizing neuromuscular blocking agents)
Drugs that affect neuromuscular transmission (amino-glycoside antibiotics, long term adrenocorticosteroids, calcium channel blockers)
Impaired muscle function (electrolyte imbalance, malnutrition, peripheral nerve disorders, atrophy, fatigue)
Know critical values for oxygenation and ventilation failure
Oxygenation
PaO2/FiO2 < 200
PaO2/PAO2 < 0.15
P(A-a)O2 > 450 mmHg
PaO2 < 70 mmHg on 0.6+ FiO2
Ventilation
pH <7.25 PaCO2 55mmHg and rising
vd/vt ratio >.6
Normal & critical values for:
VC
MIP
MEP
FEV1
PEFR
A-a difference
P/F ratio
PaO2/PAO2
Do these indicate the need for ventilatory support?
VC
normal: 65-75 ml/kg
critical: <10-15 ml/kg
MIP
normal: -100 to -50 cmH2O
critical: -20 to 0 cmH2O
MEP
normal: 100 cmH2O
critical: < 40 cmH2O
FEV1
normal: 50-60 mL/kg
critical: <10 mL/kg
PEFR
normal: 350-600 L/min
critical: 75-100 L/min
A-a difference
normal: 5-20
critical: > 450 on O2
P/F ratio
normal: 475
critical: < 200
PaO2/PAO2
normal: 0.75
critical: < 0.15

How to calculate percentage of dead space in pt’s Vt, given Vt or IBW and mechanical dead space data
PRACTICE:
Vd/Vt = .30, Vt = 500 mL
How much of the Vt is dead space?
How much reaches functioning alveoli?
What is the Vd/Vt ratio? Is it critical?
Vd = .30 × 500 = 150 mL
500 - 150 =350 mL available for gas exchance
150/350 mL =0.43 mL → NOT critical (critical > 0.60)
vent options: start breath, vent controls, how breaths are delivered
① WHO STARTS THE BREATH?
Mandatory
Vent controls delivery of the preset VT or pressure
Ventilator starts the breath
Assisted
Pt starts the breath → vent delivers preset support
Patient triggers; vent delivers the programmed breath
Spontaneous
Patient starts and controls the breath
Patient controls timing; VT depends on patient effort/demand + support provided
② WHAT DOES THE VENT CONTROL?
Volume
Pressure
③ HOW ARE THE BREATHS DELIVERED?
Mandatory
Intermittent
Spontaneous
Discuss the advantages of volume-controlled ventilation
What do we set
VT → stays constant
What varies?
pressure
WHY USE IT?
VT is guaranteed
Controls Ve
Predictable ventilation
flow changes pressure
↑ Flow → ↑ PIP
Discuss the disadvantages of volume-controlled ventilation in relation to airway pressure (compliance and resistance)
↓ Compliance / ↑Resistance → ↑ airway pressure
Pressure must be watched
Know what factors impact VCV
WHAT CHANGED?
↓Compliance
↑
Airway resistance
VT or PEEP
WHAT HAPPENS?
↑ in
PIP + Pplat
PIP
airway pressures
FLOW= VT/Ti
↓ Ti to ↑
When compliance decreases, PIP + Pplat INCREASE
When airway resistance increases, PIP INCREASES + Pplat stays the same
When Vt or PEEP increases, AIRWAY PRESSURES INCREASE
Flow pattern can affect MAP
Pt stable on VCV. Vt hasn’t changed.
PIP suddenly rises, but Pplat stays the same. What changed?
Pt stable on VCV. Vt hasn’t changed.
Both PIP and Pplat suddenly rise. What changed?
airway resistance Raw has increased
compliance has decreased (lungs became stiffer)
In a constant flow pattern (VCV), how is PIP affected? MAP?
What is another disadvantage of the constant flow pattern?
PIP is usually higher, lower MAP
Can lead to pt-vent asynchrony, air hunger if flow is lower than pt’s spontaneous breaths
Discuss the advantages of pressure-controlled ventilation
What do we set
pressure → stays constant
What varies?
Vt
varies with
compliance
resistance
WHY USE IT?
limits insp pressure
decelerating insp flow
useful when pressure limitation matters.
Disease examples
ARDS
emphysema
pulm fibrosis
infants
Discuss the disadvantages of pressure-controlled ventilation
WHAT'S THE CATCH?
Vt is NOT guaranteed will ↓ Vt
↓ Compliance
↑Resistance
Know what factors impact PCV
PRESSURE
↑ PC → ↑ VT
↓ PC → ↓ VT
LUNG CHARACTERISTICS
↓ Compliance → ↓ VT
↑ Resistance → ↓ VT
Resistance improves = ↑ VT
PATIENT EFFORT
↑ Inspiratory effort → ↑ VT
Patient participation can change the delivered VT
INSPIRATORY TIME
Longer Ti may ↑ VT — but only while inspiratory flow continues
In decelerating flow pattern (PCV), how is PIP affected? MAP?
What is another disadvantage to the decelerating flow pattern?
PIP is usually lower, higher MAP
Shorter Te, higher risk of gas trapping for pts with obstruction
In PCV, if the pressure is set higher, the Vt _____ (increases or decreases)
If the pressure is set lower, the Vt. _______
increases
decreases
In PCV, what ↓ Vt
In PCV, what ↑ Vt
↑ Raw
↓ compliance
Increased inspiratory effort
In SIMV/VC + PS, how to mandatory, assisted, and spontaneous breaths differ?
In SIMV/PC + PS, how to mandatory, assisted, and spontaneous breaths differ?
Mandatory: synchronized, time-triggered breaths are delivered by vent at set Vt.
Assisted: At patient trigger that occurs DURING synchronized mandatory window, vent delivers set Vt.
Spontaneous: At patient trigger that occurs OUTSIDE mandatory window, patient takes their own breath with preset PS.
Mandatory: synchronized, time-triggered breaths are delivered by vent at set insp pressure.
Assisted: At patient trigger that occurs DURING synchronized mandatory window, vent delivers set insp pressure.
Spontaneous: At patient trigger that occurs OUTSIDE mandatory window, patient takes their own breath with preset PS.
In PS/CPAP, are there mandatory or assisted breaths?
Describe the spontaneous breath in this mode.
NO mandatory/assisted breaths, ALL are triggered by patient.
PS provides a pressure boost on inspiration, and CPAP maintains baseline positive pressure throughout cycle.
(Apnea backup parameters may be set)
In PRVC, what happens during mandatory breaths?
Assisted breaths?
Mandatory: At time trigger, vent delivers pressure-regulated breaths, adjusting insp pressure to reach achieve target Vt.
Assisted: At patient trigger, vent delivers an additional pressure-regulated breath, adjusting insp pressure to reach achieve target Vt.
Breath type: mandatory
Trigger: vent OR pt
Targeted: Vt
Regulated: Pressure, adjusted based on prev. breath’s Vt
pressure regulated, targeted volume
Do we use 80% Total PEEP in obstructive patients to improve vent synchrony
YES
ex:A patient with COPD demonstrates repeated ineffective inspiratory efforts. Set PEEP is 6 cmH₂O, and an expiratory hold reveals total PEEP of 15 cmH₂O. What external PEEP setting would you recommend to reduce trigger workload?
__________ cmH₂O (numbers only not units)
USE THE CLASS/LAB value of setting PEEP at 80% of TOTAL PEEP
15 × 0.8 = 12
2 methods for SBT
RSBI equatinon?
SBT
low-level PS/CPAP
T- piece
RSBI
RR ÷ VT (L)
Historically, >105 suggests
greater likelihood of failure
RSBI calculation is >105 considered a failure?
RSBI = RR / Vt (L)
YES, >105 suggests greater likelihood of
failure
VAPS vs PAV vs MMV vs APRV
Pressure Augmentation (VAPS)
A dual-control mode combining pressure and volume.
The patient initiates spontaneous breaths.
PAV (Proportional Assist Ventilation)
Provides assistance proportional to the patient's inspiratory effort.
More patient effort → more ventilator assistance. Less patient effort → less ventilator assistance.
MMV (Mandatory Minute Ventilation)
The RT sets a minimum minute ventilation (VE).
The patient breathes spontaneously.
The ventilator monitors actual minute ventilation. If VE falls below the minimum → ventilator adds support.
APRV (Airway Pressure Release Ventilation)
Maintains a high airway pressure with brief release to lower pressure
Spontaneous breathing my occur
Familiarity with: APRV
TWO PRESSURE LEVELS + TWO TIMES
Set PHigh and PLow
Spends most of the time at PHigh
Briefly releases to PLow
Set THigh and TLow
LONG TIME HIGH → recruitment/oxygenation
BRIEF RELEASE LOW → ventilation/CO₂
removal
Patient can breathe spontaneously throughout
Think: HIGH … HIGH … HIGH … quick release … HIGH
Often considered in severe hypoxemic respiratory failure, such as: ARDS
Long THigh helps maintain alveolar recruitment
Allows spontaneous breathing
Uses an inverse-ratio-type pattern: much longer at high pressure than low
Not appropriate for every patient
More APRV mechanics/settings in spring
Breath type: mandatory and spontaneous
Set: 2 pressure levels (Phigh + Plow) and 2 times (Thigh + Tlow)
Uses an inverse-ratio type pattern: much longer at high pressure than low
Familiarity with: MMV
The RT sets a minimum minute ventilation (VE).
The patient breathes spontaneously.
The ventilator monitors actual minute ventilation.
If VE falls below the minimum → ventilator adds support. o Important for NBRC
Breath type: spontaneous OR mandatory
Trigger: Pt OR vent
Targeted: set Ve
If the pt stops spont breathing and Ve drops, vent automatically steps in and delivers VC or PC mandatory breaths to meet target Ve
Familiarity with: VSV
PRVC FOR SPONTANEOUS BREATHERS
Volume targeted + pressure regulated
Patient triggers every breath → spontaneous mode
Vent adjusts pressure support to move VT toward the target
Flow-cycled
“PRVC w/o a rate“
Breath type: spontaneous
Trigger: Patient
Targeted: Vt
Regulated: Pressure support
(THINK → PRVC FOR SPONT)
Familiarity with: pressure augmentation (VAPS)
A dual-control mode combining pressure and volume.
The patient initiates spontaneous breaths.
Ventilator adjusts pressure assistance to reach the target VT
One proprietary name for this is “VAPS”
– set minimum RR, PS, target volume
Breath type: spontaneous and mandatory if necessary
VOLUME-targeted, PRESSURE-limited
Set: minimum RR, PS, target Vt
Calculate tubing compliance and determine volume loss caused by tubing compliance
if higher pressure → greater compression volume loss
Compliance = ∆ Volume / ∆ Pressure
PIP x CT
then subtract this from the set Vt to determine actual delivered Vt
in units of cmH2O
Is this bringing back bad memories from 1st year?
New equation Volume Lost due to CT factor:
example
Volume loss caused by tubing compliance
Vlost = Ctubing x ∆P
Pressure change is generally PIP – PEEP
Example:
Tubing compliance = 1.5 mL/cmH2O
PIP = 30 cmH2O
Set VT = 500 mL
Volume lost:
30 x 1.5 = 45 mL
Volume actually delivered to the patient:
500 – 45 = 455 mL
Example for finding volume lost
Volume lost = Peak pressure (PIP) x CT
Volume lost = Peak pressure (PIP) x CT
** What Vt is delivered when pt’s PIP = 30 cmH2O, CT
calculated at 1.5 ml/cmH2O and Vt set on the
vent = 500 ml?
Volume lost = 30 cmH2O x 1.5 ml/cmH2O
Volume lost = 45 ml
Subtract 45 ml from 500
Delivered Vt = 455 ml
Calculate mechanical dead space and understand its impact on alveolar ventilation
Mechanical dead space = volume added by equipment that does not participate in gas exchange
ETT reduces dead space by bypassing the upper airway
With ETT: ~1 mL/kg IBW
Without ETT: ~1 mL/lb IBW
Anatomical dead Space equation
VD/VT = VD ÷ VT x 100 (to express as a %)
Physiological dead Space
(PaCO2-PECO2)/PaCO2
HME:
adds 20–90 mL
Corrugated tubing:
~50 mL per 6 inches
Clinical takeaway:
More equipment between pt and circuit → more dead space → less effective alveolar ventilation
Using MV = RR x Vt, be able to calculate any variable if given two others
MV= RR x Vt
RR= MV/Vt
Vt= MV/RR
Utilize Vt = Ti x flow calculation in various scenarios
VT = Flow x Ti
TI = VT / Flow
Flow = VT / Ti

VT= Ti x flow example question
Flow is generally calibrated in L/min
Vt = flow * Ti
If Vt = 500 ml and Flow is set at 2L/sec, how long is the Ti?
Vt / flow = Ti
.5L / 2 L/sec = 0.25 seconds
You try:
What’s the flow when:
Vt = 400 ml and Ti = 0.8 sec?
Vt = flow * Ti
VT / flow = TI
Vt / Ti = flow
Calculate TCT, Ti, Te, flow in L/min, and I:E ratios given the necessary data
Flow = VT / Ti
TCT = Ti + Te or 60/RR
i:e = Ti/Ti :Te/Ti
TCT 60 ÷ RR
Ti (VT in L × 60) ÷ Flow
Te TCT – Ti
Flow (L/min) = (VT × 60) ÷ Ti
Ti (sec) = (VT × 60) ÷ Flow
VT (L) = (Flow × Ti) ÷ 60
I:E 1 : (Te ÷ Ti)
Example
Given:
RR = 20 breaths/min
Ti = 0.75 seconds
Step 1: Find TCT
TCT = 60 ÷ 20 = 3 seconds
Step 2: Find Te
Te = 3 − 0.75 = 2.25 seconds
Step 3: Find I:E
I:E = 1 : (2.25 ÷ 0.75)
Final Answer: I:E = 1:3
RR 60 ÷ TCT