52 Terms

1
New cards

Summer Solstice

Occurs on June 21st when the Northern Hemisphere is tilted at its maximum angle toward the Sun, with direct solar rays hitting perpendicular (90∘90^\circ) at the Tropic of Cancer (23.5∘ N23.5^\circ\,\text{N} latitude).

2
New cards

Winter Solstice

Occurs on December 21st / 22nd when the Northern Hemisphere is tilted at its maximum angle away from the Sun, with direct solar rays hitting perpendicular (90∘90^\circ) at the Tropic of Capricorn (23.5∘ S23.5^\circ\,\text{S} latitude).

3
New cards

Equinoxes

The Spring / Vernal Equinox (March 21st) and Fall / Autumnal Equinox (September 23rd), during which neither pole is tilted toward the Sun and direct solar rays align over the Equator (0∘0^\circ latitude), resulting in equal day and night durations globally.

4
New cards

Radiance

Emitted radiation coming directly at the solar source.

5
New cards

Irradiance

Incident radiation striking a receiver surface.

6
New cards

Direct Normal Irradiance (DNI)

Unobstructed solar rays striking perpendicular (90∘90^\circ) to parallel rays.

7
New cards

Diffuse Irradiance

Solar radiation scattered or absorbed by clouds, water vapor, dust, and smog.

8
New cards

Global Horizontal Irradiance (GHI)

Total incident radiation hitting a flat horizontal surface (0∘0^\circ), calculated as GHI=Direct+Diffuse\text{GHI} = \text{Direct} + \text{Diffuse}.

9
New cards

Global Tilt Irradiance (GTI)

Radiation incident on a fixed tilted surface, used to estimate photovoltaic system output.

10
New cards

Hadley Cell

An atmospheric circulation cell operating between the Equator (0∘0^\circ) and 30∘ N/S30^\circ\,\text{N/S}, where equatorial solar heating causes warm air to rise at the ITCZ, flow poleward, cool, and sink at 30∘ N/S30^\circ\,\text{N/S} (Subtropical High).

11
New cards

Ferrel Cell

A mid-latitude atmospheric circulation cell operating between 30∘−60∘ N/S30^\circ - 60^\circ\,\text{N/S}, characterized by prevailing Westerly winds.

12
New cards

Polar Cell

A high-latitude atmospheric circulation cell operating between 60∘−90∘ N/S60^\circ - 90^\circ\,\text{N/S}, where sinking cold air at the poles creates Polar Easterlies.

13
New cards

Urban Heat Island Effect (UHIE)

A localized microclimate phenomenon where built-up materials absorb solar heat and re-radiate it, altering local microclimates and increasing building cooling loads.

14
New cards

Stack Effect

A thermal mechanism where warm internal air rises and exhausts through upper envelope openings, creating negative pressure at low levels that draws cool outside air inside.

15
New cards

First Law of Thermodynamics

A fundamental law stating energy cannot be created or destroyed, only transformed or transferred across system boundaries, keeping total energy in an isolated system constant.

16
New cards

Second Law of Thermodynamics

A fundamental law stating spontaneous processes increase global entropy (ΔS≥0\Delta S \ge 0), degrading useful work capacity as heat cascades down temperature gradients into ambient surroundings.

17
New cards

Isolated System

A thermodynamic system boundary permitting NO exchange of matter and NO exchange of energy (heat or work), such as a theoretical ideal thermos flask.

18
New cards

Closed System

A thermodynamic system boundary permitting exchange of energy (heat/work) but PROHIBITING exchange of matter, such as a sealed double-glazed window unit.

19
New cards

Open System

A thermodynamic system boundary permitting free exchange of BOTH matter and energy, such as an open room, building envelope, or urban ecosystem.

20
New cards

Exergy

The maximum theoretical useful work obtainable from a system as it comes into equilibrium with its surrounding reference environment (T0T_0).

21
New cards

Exergy Matching

The strategy of reserving high-grade energy sources for high-grade work and using low-exergy sources (e.g., 150∘F150^\circ\text{F} hydronic loops or 95∘F95^\circ\text{F} radiant panels) to satisfy low-grade heating requirements (e.g., 70∘F70^\circ\text{F} indoor air).

22
New cards

Energy Use Intensity (EUI)

A building energy measurement metric expressed in kBtu/sf/yr\text{kBtu/sf/yr}, quantifying energy consumption per unit of floor area.

23
New cards

Site EUI vs. Source EUI

Site EUI measures energy consumption directly at the utility meter, whereas Source EUI accounts for total energy including extraction, generation, transmission, and distribution losses.

24
New cards

Visible Light Transmittance (VLT)

The percentage of visible electromagnetic radiation admitted through glazing, directly impacting interior illuminance levels and daylighting autonomy.

25
New cards

Window-to-Wall Ratio (WWR)

The ratio of fenestration area to gross exterior wall area, prescriptively regulated under IECC §C402.4 to cap envelope thermal losses and gains.

26
New cards

North Glazing

Building fenestration facing North that delivers consistent, diffuse sky radiation without direct glare or thermal overheating.

27
New cards

South Glazing

Building fenestration facing South that is easily shaded in summer with horizontal overhangs and admits winter passive heat gains when solar altitude angles are low.

28
New cards

Daylight Glazing (Upper)

Apertures placed above eye level (7′ ⁣−0′′−9′ ⁣−0′′ AFF7'\!-0'' - 9'\!-0''\,\text{AFF}) with high VLT (0.60−0.800.60 - 0.80), paired with interior light shelves to bounce light deep onto ceilings.

29
New cards

View Glazing (Lower)

Apertures placed at vision level (3′ ⁣−0′′−7′ ⁣−0′′ AFF3'\!-0'' - 7'\!-0''\,\text{AFF}) with moderate VLT (0.40−0.600.40 - 0.60) and lower SHGC to control occupant glare and thermal comfort.

30
New cards

Spatial Daylight Autonomy (sDA)

A daylight performance metric measuring the percentage of work area receiving sufficient daylight (≥300 lux\ge 300\,\text{lux}) for at least 50%50\% of operating hours.

31
New cards

Annual Sun Exposure (ASE)

A daylight performance metric measuring potential visual discomfort or glare from excessive direct sunlight (>1000 lux> 1000\,\text{lux} for >250 hours/year> 250\,\text{hours/year}).

32
New cards

Prescriptive Path

A code compliance approach requiring strict adherence to individual component performance thresholds, such as minimum R-values and maximum U-factors.

33
New cards

Performance-Based Path

A code compliance approach utilizing computer energy modeling to prove proposed design energy cost/use is equal to or lower than code baseline (IECC C407).

34
New cards

Accessory Occupancy

A mixed occupancy legal condition under IBC §508.2 where an accessory space comprises ≤10%\le 10\% of a story floor area, requiring no fire separation.

35
New cards

Separated Occupancies

A mixed occupancy legal condition under IBC §508.4 where fire barriers or horizontal assemblies separate occupancies and the sum of area ratios is ≤1.0\le 1.0.

36
New cards

Fire Area

Defined under IBC §202 as the aggregate floor area enclosed and bounded by fire walls, fire barriers, exterior walls, or rated horizontal assemblies.

37
New cards

Fire Wall

An IBC §706 wall assembly with a 3-hour3\text{-hour} or 4-hour4\text{-hour} fire-resistance rating that divides a structure into legally independent buildings, extending continuously from foundation through roof with structural independence.

38
New cards

Fire Barrier

An IBC §707 wall assembly with a 1-hour1\text{-hour} or 2-hour2\text{-hour} fire-resistance rating that encloses exit stairways, shafts, separated occupancies, and fire area boundaries continuously slab-to-deck.

39
New cards

Fire Partition

An IBC §708 wall assembly with a 0.5-hour0.5\text{-hour} or 1-hour1\text{-hour} fire-resistance rating used for corridor walls, tenant separations, and dwelling unit walls.

40
New cards

Smoke Barrier

An IBC §709 wall assembly with a 1-hour1\text{-hour} fire-resistance rating that restricts the movement of smoke into compartments, extending continuously slab-to-deck.

41
New cards

Fire-Protection Glazing vs. Fire-Resistance Glazing

Fire-protection glazing is tested for flame/smoke passage with limited surface area in rated walls, whereas fire-resistance glazing is tested under ASTM E119 to block radiant heat transmission and maintain structural integrity.

42
New cards

Exit Access

The portion of a means of egress system that leads from any occupiable point in a building to an exit.

43
New cards

Exit

The protected, fire-resistance-rated portion of a means of egress system that leads directly to the exit discharge or public way, such as interior exit stairways or exit passageways.

44
New cards

Exit Discharge

The portion of a means of egress system between the termination of an exit and a public way.

45
New cards

Diagonal Rule

An IBC §1007.1.1 requirement stating two exits must be separated by at least 12\frac{1}{2} the maximum diagonal dimension of the area served (reduced to 13\frac{1}{3} in sprinklered buildings).

46
New cards

Common Path of Egress Travel

The maximum distance an occupant must travel before two distinct and independent exit access paths become available (75 ft75\,\text{ft} unsprinklered; 100 ft100\,\text{ft} sprinklered Group B).

47
New cards

Exit Access Travel Distance

The maximum overall distance from the most remote occupiable point to an exit door (200 ft200\,\text{ft} unsprinklered Group B; 300 ft300\,\text{ft} sprinklered Group B).

48
New cards

Dead-End Corridor Limit

The maximum allowable corridor pocket length beyond an exit (20 ft20\,\text{ft} max unsprinklered; 50 ft50\,\text{ft} max sprinklered for Group B/E/F/M/R/S).

49
New cards

Smokeproof Enclosure

An IBC §1023.11 exit stairway requirement for floors >75 ft> 75\,\text{ft} above fire access or >30 ft> 30\,\text{ft} below grade, achieved via vestibule ventilation or mechanical shaft pressurization.

50
New cards

Area of Refuge

An IBC §1009.6 space providing at least one 30 in×48 in30\,\text{in} \times 48\,\text{in} wheelchair space per 200200 occupants served, separated by a smoke barrier and equipped with two-way communication.

51
New cards

Accessible Turning Space

An ADA and ICC A117.1 required floor space consisting of a 60 in60\,\text{in} diameter turning circle or T-shaped turning space for wheelchair maneuverability.

52
New cards

Accessible Water Closet Clearance

A clear floor space measuring 60 in60\,\text{in} wide by 56 in56\,\text{in} deep around a water closet, with centerline 16 in−18 in16\,\text{in} - 18\,\text{in} from side wall and seat height 17 in−19 in AFF17\,\text{in} - 19\,\text{in}\,\text{AFF}.