1/34
Looks like no tags are added yet.
What is the first step in determining the amount and types of apparatus needed for a water shuttle?
The fire flow
According to NFPA 1900, a tender must have a water tank of at least:
1000 gal (4000 L)
The must suitable fill site to meet fire flow requirements:
May not be the closest to the incident
Preplanning for large-scale water shuttle operations derives from
A community risk assessment
What is the preplanned route for travel for tenders for a jurisdiction or target hazard called?
Traffic plan
When operating at incidents located on a dead-end street, it may be advantageous to set up a dump site:
At the nearest intersection
The goal of the fill site is to load tenders:
As safely and efficiently as possible
After determining the exact fill spot, denote the stopping point for the D/O of the tender with a:
Traffic cone
When setting up a fill site, place the marker for the stopping point for the tender:
Adjacent to the driver’s side door
Under ICS, water shuttle operations are under the Operations section and is called the:
Water Supply Group
Tenders that use medium-diameter supply hose for filling should have:
At least two external fill connections piped to the tank
An evolution where a tender supplies a line and pumps water to the attack pumper is known as:
A rural hitch
A dump site method where a large tender is immediately adjacent to the attack pumper and acts as a drop tank is known as:
Nurse tender operations
Generally, when filling a portable tank at a dump site, pumping through a discharge is:
Less efficient than using a dump valve
NFPA 1900 requires all tenders to dump at a minimum average flow of 1000 gpm (4000 L/min) for the first ____ of tank capactity
90%
Single portable tank operations work for firefighting situations that require flow rates less than:
300 gpm (1200 L/min)
IFSTA recommends that any tank, regardless of type, should have a capacity of at least ___ more than the water tank on the apparatus that will supply it
500 gal (2000 L)
The dump site pumper can use a ___ to allow for continuous drafting to a point of about 2in (50mm)
Low-level strainer
Incidents that require a flow rate in excess of ___ are best served by a multiple portable tank operation
300 gpm (1200 L/min)
So that water may be transferred from one tank to another, multiple portable water tanks must be positioned in:
Series
What is an effective method used to move water between portable water tanks?
Use of jet siphon
For dump site operations requiring more than 3 tanks using jet siphons with flows over 500gpm (2000 L/min):
A second pumper may be used to draft and supply the jet siphon
If possible, fill tenders at a rate of:
1000 gpm (4000 L/min)
When positioning to draft at a static source, seek a position that:
Requires minimum lift to maximize the flow available
When operating at a fill site, position the tender so that:
A minimum amount of hose is required from the fill site
Fill times can be decreased when filling a tender using a medium diameter hose by:
Using multiple MDH hoselines
A tender D/O entering a fill site should:
Proceed until the driver’s door is parallel to the traffic cone or other marking device
A tender D/O will typically give a ___ prior to moving the apparatus
Horn signal
Once drafting operations are completed, and prior to returning the drafting site pumper to service:
Backflush the apparatus with water to lessen the chance of contamination
What is the water shuttle flow rate for a 3000 gal (12000 L) tender that makes a 1mi (1.5km) dump between fill sites in 12mins?
Flow = 0.9 x TS x TT
225 gpm (900 L/min)
Assuming an average travel speed of 35mph (55 km/h), what is the travel time for a tender that must complete a 5mi (8km) water shuttle operation?
Travel Time = 0.65 + (1.06 x distance)
9.13 minutes
What is the handling time for a 4000 gal (8000 L) tender that has a fill/dump rate of 2000 gpm (4000 L/min)? Assume a make-and-break time of 2mins at each site
Handling Time = Fill Site Time + Dump Site Time
8 minutes
Determine the flow rate for a 2500 gal (10000 L) tender with a fill/dump rate of 1000 gpm (4000 L/min) that must complete a shuttle run of 4mi (8km) in each direction. Assume maneuvering and make-and-break times total 1.5 minutes at each site.
Flow = (0.9 x tank size) + (travel time + handling time)
101.12 gpm (338.22 L/min)
Due to their weight, D/O’s of mobile water supply apparatus need to pay particular attention to the:
Brake systems
Prior to performing daily/weekly visual and operational checks on a mobile water supply apparatus, the D/O should:
Consult manufacturers’ specifications