What is the first step in determining the amount and types of apparatus needed for a water shuttle?

The fire flow

2
New cards

According to NFPA 1900, a tender must have a water tank of at least:

1000 gal (4000 L)

3
New cards

The must suitable fill site to meet fire flow requirements:

May not be the closest to the incident

4
New cards

Preplanning for large-scale water shuttle operations derives from

A community risk assessment

5
New cards

What is the preplanned route for travel for tenders for a jurisdiction or target hazard called?

Traffic plan

6
New cards

When operating at incidents located on a dead-end street, it may be advantageous to set up a dump site:

At the nearest intersection

7
New cards

The goal of the fill site is to load tenders:

As safely and efficiently as possible

8
New cards

After determining the exact fill spot, denote the stopping point for the D/O of the tender with a:

Traffic cone

9
New cards

When setting up a fill site, place the marker for the stopping point for the tender:

Adjacent to the driver’s side door

10
New cards

Under ICS, water shuttle operations are under the Operations section and is called the:

Water Supply Group

11
New cards

Tenders that use medium-diameter supply hose for filling should have:

At least two external fill connections piped to the tank

12
New cards

An evolution where a tender supplies a line and pumps water to the attack pumper is known as:

A rural hitch

13
New cards

A dump site method where a large tender is immediately adjacent to the attack pumper and acts as a drop tank is known as:

Nurse tender operations

14
New cards

Generally, when filling a portable tank at a dump site, pumping through a discharge is:

Less efficient than using a dump valve

15
New cards

NFPA 1900 requires all tenders to dump at a minimum average flow of 1000 gpm (4000 L/min) for the first ____ of tank capactity

90%

16
New cards

Single portable tank operations work for firefighting situations that require flow rates less than:

300 gpm (1200 L/min)

17
New cards

IFSTA recommends that any tank, regardless of type, should have a capacity of at least ___ more than the water tank on the apparatus that will supply it

500 gal (2000 L)

18
New cards

The dump site pumper can use a ___ to allow for continuous drafting to a point of about 2in (50mm)

Low-level strainer

19
New cards

Incidents that require a flow rate in excess of ___ are best served by a multiple portable tank operation

300 gpm (1200 L/min)

20
New cards

So that water may be transferred from one tank to another, multiple portable water tanks must be positioned in:

Series

21
New cards

What is an effective method used to move water between portable water tanks?

Use of jet siphon

22
New cards

For dump site operations requiring more than 3 tanks using jet siphons with flows over 500gpm (2000 L/min):

A second pumper may be used to draft and supply the jet siphon

23
New cards

If possible, fill tenders at a rate of:

1000 gpm (4000 L/min)

24
New cards

When positioning to draft at a static source, seek a position that:

Requires minimum lift to maximize the flow available

25
New cards

When operating at a fill site, position the tender so that:

A minimum amount of hose is required from the fill site

26
New cards

Fill times can be decreased when filling a tender using a medium diameter hose by:

Using multiple MDH hoselines

27
New cards

A tender D/O entering a fill site should:

Proceed until the driver’s door is parallel to the traffic cone or other marking device

28
New cards

A tender D/O will typically give a ___ prior to moving the apparatus

Horn signal

29
New cards

Once drafting operations are completed, and prior to returning the drafting site pumper to service:

Backflush the apparatus with water to lessen the chance of contamination

30
New cards

What is the water shuttle flow rate for a 3000 gal (12000 L) tender that makes a 1mi (1.5km) dump between fill sites in 12mins?

Flow = 0.9 x TS x TT

225 gpm (900 L/min)

31
New cards

Assuming an average travel speed of 35mph (55 km/h), what is the travel time for a tender that must complete a 5mi (8km) water shuttle operation?

Travel Time = 0.65 + (1.06 x distance)

9.13 minutes

32
New cards

What is the handling time for a 4000 gal (8000 L) tender that has a fill/dump rate of 2000 gpm (4000 L/min)? Assume a make-and-break time of 2mins at each site

Handling Time = Fill Site Time + Dump Site Time

8 minutes

33
New cards

Determine the flow rate for a 2500 gal (10000 L) tender with a fill/dump rate of 1000 gpm (4000 L/min) that must complete a shuttle run of 4mi (8km) in each direction. Assume maneuvering and make-and-break times total 1.5 minutes at each site.

Flow = (0.9 x tank size) + (travel time + handling time)

101.12 gpm (338.22 L/min)

34
New cards

Due to their weight, D/O’s of mobile water supply apparatus need to pay particular attention to the:

Brake systems

35
New cards

Prior to performing daily/weekly visual and operational checks on a mobile water supply apparatus, the D/O should:

Consult manufacturers’ specifications