1
New cards
2
New cards
3
New cards
4
New cards
Microtome
Machine or instrument used for cutting tissue sections.
5
New cards
Sectioning
Process whereby tissues are cut into uniformly thin slices to facilitate microscopic study.
6
New cards
Paldwell Trefall
Inventor of the rocking (Cambridge) microtome.
7
New cards
Rocking (Cambridge) Microtome
Microtome used for cutting serial sections of large blocks; tissue passes the knife in a slightly curved plane.
8
New cards
Minot
Inventor of the rotary microtome.
9
New cards
Rotary Microtome
Microtome used for cutting serial sections and glycol methacrylate; common in laboratories.
10
New cards
Adams
Inventor of the sliding microtome.
11
New cards
Sliding Microtome
Microtome that includes a base sledge type and standard sliding type.
12
New cards
Base Sledge Microtome
Type of sliding microtome in which the block holder moves.
13
New cards
Queckett
Inventor of the freezing microtome.
14
New cards
Freezing Microtome
Microtome associated with a CO2 chamber and used for demonstrating fats and neurological structures.
15
New cards
Cryostat or Cold Microtome
Instrument for preparing large, thin, often wrinkled sections of fresh frozen tissues; permits rapid biopsy preparation.
16
New cards
Ultrathin Microtome
Microtome used to cut ultrathin sections.
17
New cards
Vibrotome
Used for sectioning unfixed, unfrozen specimens for enzyme demonstrations.
18
New cards
Low-profile Blade
One of the two classifications of microtome blades.
19
New cards
High-profile Blade
One of the two classifications of microtome blades.
20
New cards
Good Cutting Edge
Good-quality steel edge that cuts paraffin blocks about 2–3 micra thick without serration.
21
New cards
Knife Bevel
Cutting facet of a microtome knife.
22
New cards
Knife Holder Base
Anchors the knife holder to the microtome stage; must be stationary and locked during microtomy.
23
New cards
Knife Holder
Assembly with blade clamp, knife tilt, and face plate.
24
New cards
Blade Clamp
Component of the knife holder that secures the blade.
25
New cards
Knife Tilt
Adjusts the knife angle.
26
New cards
Face Plate
Guides ribbons away from the blade toward the operator.
27
New cards
Cassette Clamp / Block Holder
Holds the paraffin block and moves up and down with each revolution while the blade remains stationary.
28
New cards
Coarse Hand Wheel
Moves the block holder toward or away from the knife.
29
New cards
Advancement Hand Wheel
Advances the block toward the knife at the specified micron setting.
30
New cards
Safety Lock
Prevents the hand wheel from releasing and the block holder from descending while inserting or removing a block.
31
New cards
Micron Adjustment
Controls section thickness; most microtomes range from 1–60 microns.
32
New cards
Rotary Microtome Parts
Base, block holder, block adjustment screw, knife holder, blade clamps, tilt adjustment, thickness gauge, handle, face plate, and waste tray.
33
New cards
Microtome Knife Parts
Blade, knife carrier, handle, and bevel.
34
New cards
Ratchet Wheel
Wheel connected to a micrometer screw that advances the tissue block at a predetermined distance.
35
New cards
Section Thickness for Routine Histology
Sections are usually cut at 4–6 microns thick.
36
New cards
Clearance Angle
Knife is usually tilted 0–15° to allow clearance between the cutting facet and tissue block.
37
New cards
Factors Affecting Cutting Rate
Type of tissue, size of the block, and microtome model or type.
38
New cards
Incomplete Sections
Sections that should be discarded.
39
New cards
Methods of Picking Up Complete Ribbons
Camel hair brush, forceps, or fingers.
40
New cards
Static Electricity Reduction
Gently exhaling on the section while slowly cutting tissues that tend to crumble.
41
New cards
Microtome Cleaning
Brush away accumulated paraffin and tissue fragments after sectioning.
42
New cards
Microtome Maintenance
Dry the machine and knife holder, wipe parts with xylol, oil movable parts, and cover when not in use.
43
New cards
Paraffin Section
Type of tissue section.
44
New cards
Celloidin Section
Type of tissue section.
45
New cards
Frozen Section
Type of tissue section.
46
New cards
Honing
Sharpening a knife to remove nicks from the cutting edge.
47
New cards
Hone
Natural sharpening stone or hard grinding surface such as carborundum.
48
New cards
Coarse Honing
Initial honing/sharpening stage.
49
New cards
Honing Proper
Sharpening stage following coarse honing.
50
New cards
Honing Lubricants
Mineral and clove oil, xylene, liquid paraffin, or soapy water.
51
New cards
Honing Direction
Knife is drawn edge-first, heel-to-toe, diagonally toward the operator.
52
New cards
Double Stroke in Honing
Knife is turned over and the other surface is drawn forward edge-first, heel-to-toe.
53
New cards
Stropping
Removes burrs formed during honing.
54
New cards
Stropping Direction
Edge-last; pushed backward and drawn forward toe-to-heel.
55
New cards
Stropping Strokes
Approximately 40–120 strokes.
56
New cards
Flotation Water Bath
Water bath with a black inner wall used to flatten tissue sections.
57
New cards
Flotation Water Bath Temperature
Must be lower than the melting point of paraffin wax.
58
New cards
Surface Tension Reduction
A small amount of an additive may be placed in the water to help sections flatten.
59
New cards
Paraffin Oven
Used to dry specimens after fishing-out; temperature is maintained above the melting point of paraffin wax.
60
New cards
Slide Drying Requirement
Tissue sections must be completely dried before staining.
61
New cards
Routine Glass Slide Size
76 × 25 mm slides, usually 1.0–2.0 mm thick.
62
New cards
Non-frosted Slide
Commercial glass slide type.
63
New cards
Frosted Slide
Commercial glass slide type.
64
New cards
Microtome Sectioning Principle
A pawl turns a ratchet wheel connected to a micrometer screw, advancing the tissue block by a predetermined distance toward the knife.
65
New cards
Pure Physical Stains
General category of staining reactions.
66
New cards
Chemical Stains
Stains in which dye is adsorbed by cell components and bound through Van der Waals, ionic/electrostatic, or covalent bonds.
67
New cards
Factors Influencing Dye Binding
pH, temperature, dye concentration, other salts, and types of fixatives.
68
New cards
Coplin Jar
Slotted jar used in staining.
69
New cards
Slotted Staining Dishes
Materials used for staining procedures.
70
New cards
Staining Rack or Carrier
Metal or glass rack used to hold slides during staining.
71
New cards
Hematoxylin
Stain that binds strongly to acids and stains nuclei blue.
72
New cards
Eosin
Stain that colors other structures pink or red.
73
New cards
H&E Staining
Hematoxylin and eosin staining; cornerstone of tissue-based diagnosis.
74
New cards
Purpose of H&E
Allows visualization of tissue morphology and cellular structures for diagnosis.
75
New cards
Hematoxylin Ripening
Oxidation process needed to activate dye components.
76
New cards
Hematoxylin Oxidizing Agents
Hydrogen peroxide, potassium permanganate, and sodium perborate.
77
New cards
Harris Alum Hematoxylin
Used for 5 minutes in the routine H&E procedure described in the lecture.
78
New cards
Ehrlich’s Hematoxylin
Requires 15–30 minutes of staining.
79
New cards
Regressive Staining
Staining method involving excess staining followed by differentiation to remove excess stain.
80
New cards
Acid-Alcohol
1% acid-alcohol used for differentiation; made with 1 mL concentrated HCl and 99 mL of 80% ethyl alcohol.
81
New cards
Differentiation
Removal of excess stain until only nuclei remain stained.
82
New cards
Bluing
Conversion of hematoxylin-stained nuclei to blue color using ammonia water or lithium carbonate.
83
New cards
Ammonia Water
Bluing agent used for an average of 5 minutes.
84
New cards
Lithium Carbonate
Alternative bluing agent; 1% aqueous solution until sections appear blue, about 30 seconds.
85
New cards
Xylene
Used to clear paraffin and in final clearing before mounting.
86
New cards
Absolute Ethyl Alcohol
Alcohol step used in deparaffinization/hydration sequence.
87
New cards
95% Ethyl Alcohol
Alcohol used in the routine H&E staining sequence.
88
New cards
70% Ethyl Alcohol
Alcohol used after 95% alcohol during final dehydration sequence.
89
New cards
Routine H&E — Xylene 1
3 minutes.
90
New cards
Routine H&E — Xylene 2
2–3 minutes (lecture table: 3 minutes).
91
New cards
Routine H&E — Absolute Alcohol
2 minutes.
92
New cards
Routine H&E — 95% Alcohol
1–2 minutes.
93
New cards
Routine H&E — Running Water
1 minute before hematoxylin.
94
New cards
Routine H&E — Harris Hematoxylin
5 minutes.
95
New cards
Routine H&E — Acid-Alcohol
10–30 seconds with microscopic monitoring (lecture table: 15 seconds).
96
New cards
Routine H&E — Ammonium Water
Average of 5 minutes for bluing.
97
New cards
Routine H&E — Eosin
5 minutes.
98
New cards
Mounting
Final step in tissue processing resulting in a permanent histological preparation.
99
New cards
Mounting Medium
Suitable medium, usually syrupy fluid, used beneath a coverslip.
100
New cards
Mounting Purpose
Promotes adhesion, prevents specimen movement, protects, and preserves tissue.
Load more