1/30
all wk 1-2 besides ECG
ECG can diagnose
acute MI, myocardial ischemia, and electrolyte imbalances
hyperkalemia
peaked T wave
hypokalemia
U wave present
hypercalcemia
short QT
hypocalcemia
prolonged QT wave and T wave inversion
hypomagnesemia
prolongation of PR / QRS / QT; dysrhythmias such as PVCs, torsades, VF; potassium-resistant hypokalemia
width and height of small boxes
0.04 seconds ; 0.1 mV
width and height of large boxes
0.20 seconds ; 0.5mV
P waves
atrial depol. <0.12 seconds
QRS
ventricular depol. 0.06-0.1
T wave
ventricular repol.
PR wave
0.12 - 0.2
QT segment
total ventricular activity
ST segment
early repol.
horizontal plane ECG leads locations
V1 - 4th ICS RT
V2 - 4th ICS LT
V3 - mid V2-V4
V4 - 5th ICS / MCL (apical pulse)
V5 - 5th ICS / anterior axillary line
V6 - 5th ICS / mid axillary line
sinus rhythms
normal sinus, sinus brady, sinus tachy, sinus arrythmia, sinus arrest / pause → regular rhythm, differing rate
atrial dysrhythmias
PACs, atrial flutter, atrial fibrillation, MAT / WAP → impulses fire outside the SA node, look for P wave changes
junctional dysrhythmias
PJC, junction escape, accelerated junctional rhythm, junctional tachycardia → AV junction takes over ; P waves inverted, hidden, or absent
ventricular dysrhythmias
PVC, idioventricular rhythm, AIVR, ventricular tachy, ventricular fibrillation, torsades de pointes, asytole → originated impulses below AV junction / in ventricular tissue ; look for widened QRS
AV blocks
first degree, Mobitz 1, Mobitz 2, third-degree / complete → conduction between atria and ventricles are delayed / interrupted
pacemaker ECG findings
bump BEFORE p wave, atrial pacing
bump BEFORE QRS, ventricular pacing
failure to capture treatment
place patient on left side
failure to sense treatment
place patient on left side and adjust sensitivity
temporary pacemaker
transcutaneous emergent, transvenous, and epicardial ; can pace atrium, ventricle, and both chambers
permanent pacemaker
electrode wires placed transvenously through the cephalic or subclavian vein into the heart chambers
implantable cardioverter-defib. (ICD)
used to treat fast heart rhythms (like VT) w/ anti-tachycardia pacing, as well as slow heart rhythms that can occur following defib.
anti-tachycardia pacing is short and fast burst of pacing impulses that attempt to terminate tachy
biventricular pacemakers and this have additional electrode wire placed through coronary sinus into the left ventricle
vaughan-williams classes
class I - Na channel blockers (lidocaine, procainamide)
class II - BBs (metoprolol, esmolol)
class III - K channel blockers (amiodarone, sotalol)
class IV - CC blockers (ditiazem, verapamil)
other key medications in antiarrhythmic therapy
adenosine (slows AV conduction)
atropine (treats symp. brady.)
magnesium sulfate (treats torsades)
defibrillation / UNsynchronized
delivers shock at any point in cycle ; used for VF and pulseless VT ; highest survival when delivered early w/ CPR ; no sedation as pt is pulseless
synchronized cardioversion
shock timed to R wave (avoids T wave) ; used for unstable tachy w/ pulse such as AFib, flutter, and VT ; sedate pt is time allows ‘ confirm sync mode engaged before each shock
vagal maneuvers
bear down and carotid massage to slow AV conduction