chem c24 planning experiments 2

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/27

encourage image

There's no tags or description

Looks like no tags are added yet.

28 Terms

1
New cards

What does the TAMP framework stand for and what does each step involve?



T = Topic and Aim: identify the topic and aim to narrow your thinking to the relevant experimental process. 

A = Analyse clues: identify and analyse information from the question description, apparatus provided, chemicals provided, and bullet points, to adapt the typical process to the specific experiment. 

M = Measurements: decide quantities of chemicals to use and measure, either assumed or calculated from clues. 

P = Process: use the above to write a clear, coherent, step-by-step plan using the typical series of steps for that experiment type.

2
New cards

What is gravimetry and what are the two main methods used?

Gravimetry involves the accurate measurement of mass to quantify a sample. Two methods:

  1. Thermal decomposition: heating a compound until it decomposes to give a solid residue and a gaseous product, then weighing the residue.

  2. Precipitation: mixing two solutions to form an insoluble precipitate, filtering, drying, and weighing it.


3
New cards

State the general procedure for gravimetry by thermal decomposition.



 1. Record mass of empty boiling tube or crucible. 

2. Weigh accurately the compound into the container. Record total mass. 

3. Heat gently at first to prevent spattering, then heat strongly for at least 10 minutes. 

4. Cool to room temperature (ideally in a desiccator to prevent moisture absorption). 

5. Weigh the container and its contents. 

6. Repeat the heat-cool-weigh cycle until constant mass is achieved. Constant mass ensures complete decomposition.

4
New cards

State the general procedure for gravimetry by thermal decomposition.



 1. Record mass of empty boiling tube or crucible. 

2. Weigh accurately the compound into the container. Record total mass. 

3. Heat gently at first to prevent spattering, then heat strongly for at least 10 minutes. 

4. Cool to room temperature (ideally in a desiccator to prevent moisture absorption). 

5. Weigh the container and its contents. 

6. Repeat the heat-cool-weigh cycle until constant mass is achieved. Constant mass ensures complete decomposition.

5
New cards

In the thermal decomposition of CuSO4.nH2O, how do you calculate n from the experimental masses?



Let A = mass of empty crucible, B = mass of crucible + CuSO4.nH2O, D = mass of crucible + contents after heating to constant mass. Mass of CuSO4 remaining = (D - A) g; amount of CuSO4 = (D - A)/159.6 mol. Mass of H2O driven off = (B - D) g; amount of H2O = (B - D)/18.0 mol. n = amount of H2O / amount of CuSO4 = [18.0(B - D)] / [159.6(D - A)] ... Wait, it simplifies to n = [159.6(B - D)] / [18.0(D - A)].

6
New cards

In the thermal decomposition of CuSO4.nH2O, how do you calculate n from the experimental masses?



Let A = mass of empty crucible, B = mass of crucible + CuSO4.nH2O, D = mass of crucible + contents after heating to constant mass. Mass of CuSO4 remaining = (D - A) g; amount of CuSO4 = (D - A)/159.6 mol. Mass of H2O driven off = (B - D) g; amount of H2O = (B - D)/18.0 mol. n = amount of H2O / amount of CuSO4 = [18.0(B - D)] / [159.6(D - A)] ... Wait, it simplifies to n = [159.6(B - D)] / [18.0(D - A)].

7
New cards

Why might an open crucible be more appropriate than a boiling tube for the thermal decomposition of NaHCO3?

The decomposition produces water vapour, which condenses on the cooler inner walls of a boiling tube as tiny water droplets. Further heating is needed to drive these off, making the experiment less efficient. An open crucible allows water vapour to escape more easily without condensing.

8
New cards

State the general procedure for gravimetry by precipitation.

1. Mix the two solutions.
2. Filter the mixture through a filter funnel lined with a pre-weighed filter paper.
3. Wash the precipitate with several portions of cold deionised water (to remove soluble impurities without dissolving the precipitate).
4. Dry the precipitate with the filter paper in an oven.
5. Cool in a desiccator for about 10 minutes.
6. Weigh accurately the precipitate and filter paper.
7. Repeat the dry-cool-weigh cycle until constant mass is achieved.

9
New cards

Give the precipitating reagent for: (a) SO42-, (b) Cl-/Br-/I-, (c) Ba2+, (d) Ag+. State one exception/caution for each.

(a) SO42-: BaCl2(aq) or Pb(NO3)2(aq). Caution: do not use Pb(NO3)2 if halide ions are present as lead(II) halides are insoluble and will co-precipitate.
(b) Halides: AgNO3(aq) or Pb(NO3)2(aq). Caution: do not use Pb(NO3)2 if sulfate is also present as PbSO4 is insoluble.
(c) Ba2+: H2SO4(aq) or Na2SO4(aq).
(d) Ag+: HCl(aq), NaCl(aq), KBr(aq), or KI(aq).

10
New cards

Why is NaOH(aq) not used to precipitate Pb2+, Ba2+, or Ag+?



Pb(OH)2 is amphoteric and dissolves in excess NaOH(aq), so precipitation is not complete. Ba(OH)2 has appreciable solubility in water, so Ba2+ would not be fully precipitated. AgOH is unstable and decomposes to form Ag2O rather than a clean precipitate of AgOH.

11
New cards

In a precipitation experiment, how do you check that all the target ion has been precipitated out?



Decant a small amount of the solution above the precipitate and test it with a few drops of the precipitating reagent (e.g. concentrated HCl for Pb2+). If no precipitate forms, all the target ions have been successfully precipitated and none remain in solution.

12
New cards

What apparatus is commonly used to collect gas in gas collection experiments? State one limitation of each



1. Graduated gas syringe: volume readings depend on temperature and pressure; air and gas inside are compressible.
2. Inverted burette filled with water: maximum volume only 50 cm3; soluble gases (CO2, NH3, SO2) will dissolve in water, giving inaccurate readings.
3. Inverted measuring cylinder filled with water: same limitation as the burette with soluble gases. Note: For gases soluble in water, a gas syringe must be used instead.

13
New cards

When planning a gas collection experiment, how do you decide the quantities of reagents to use? State the general approach.



Assume the volume of gas collected will be between 50% and 90% of the capacity of the gas collection apparatus. Use this assumed volume with the ideal gas equation (1 mol gas = 24 dm3 at laboratory conditions) and the stoichiometry of the reaction to calculate the required amounts of reagents. The limiting reagent is usually the solid or the reagent you are analysing, and the other reagent should be in excess.

14
New cards

List four sources of error in gas collection experiments.



1. Some gases (e.g. CO2) may dissolve in water if water displacement is used. 2. Gas may escape during the lag time between adding the reagent and replacing the stopper. 3. Variable swirling of the flask leads to inconsistent gas evolution rates. 4. Volume of gas depends on temperature and pressure, and heat from the reaction may cause thermal expansion, introducing error. The ideal gas equation must be used to convert volume to amount, but real gases deviate from ideal behaviour.

15
New cards

In the H2O2 decomposition gas collection experiment (Worked Example 4), how do you calculate [H2O2] from the volume of O2 collected?

Let average volume of O2 collected = V cm3. Volume of H2O2 used = 40.00 cm3. Amount of O2 = V/24000 mol. From 2H2O2 → 2H2O + O2, amount of H2O2 = 2 × (V/24000) = V/12000 mol. Concentration of H2O2 = (V/12000) / (40.00/1000) = V/480 mol dm-3.

16
New cards

State the two common experimental setups used in chemical energetics experiments and give one example reaction for each.



1. Polystyrene/Styrofoam cup calorimeter (for reactions in solution): used for enthalpy change of neutralisation (HCl + NaOH → NaCl + H2O), enthalpy change of solution (NH4Cl(s) + aq → NH4Cl(aq)), or enthalpy change of reaction in solution (Zn(s) + CuSO4(aq) → ZnSO4(aq) + Cu(s)).

2. Spirit lamp with metal calorimeter (for combustion experiments): used for enthalpy change of combustion (e.g. CH3CH2OH(l) + 3O2(g) → 2CO2(g) + 3H2O(l)).

17
New cards

When planning an energetics experiment where the approximate enthalpy change is given, what temperature change do you assume and why?



Assume a temperature change of 5 to 10°C. This is considered a measurable change in temperature that is large enough to reduce the relative error in the thermometer reading while still being achievable with reasonable quantities of reagents.

18
New cards

Describe the graphical method of determining temperature change in an energetics experiment involving continuous temperature monitoring.



1. Monitor temperature at regular intervals (e.g. every 0.5 min), recording at least 3 readings before adding the second reagent.
2. Add the second reagent at a set time (e.g. t = 3.0 min) and continue recording temperature at 0.5 min intervals.
3. Record at least 5 readings after the highest/lowest temperature is reached.
4. Plot temperature against time. Draw two lines of best fit: one for before addition, one for the cooling/heating trend after reaction.
5. Extrapolate both lines to t = 3.0 min and read off the temperature difference to obtain the true delta T, correcting for heat loss to surroundings.

19
New cards

Describe the thermometric titration method (Worked Example 7 type) and how the endpoint and concentration are determined.

1. Add a known volume of FA1 (e.g. NaOH) to a Styrofoam cup and measure its initial temperature.
2. Add FA2 (e.g. H2SO4) in fixed increments from a burette, measuring the highest temperature after each addition.
3. Continue until well past the endpoint, recording at least 5 readings before and after the maximum temperature.
4. Plot T against volume of FA2 added. Draw two best-fit lines and extrapolate to their intersection.
5. The intersection gives Veq (volume of FA2 at equivalence point). Use stoichiometry to calculate concentration: concentration of H2SO4 = (n(H2SO4)) / Veq × 1000.

20
New cards

In the "fixed total volume" energetics method (Worked Example 8 type), how do you ensure at least 5 readings before and after Veq?

1. First calculate the approximate Veq using the known (or approximate) concentrations and the mole ratio of the reaction.
2. Design experiments so that at least 5 volume combinations of FA1 and FA2 are used with FA2 volume below Veq, and at least 5 more with FA2 above Veq, while keeping the total volume constant throughout (e.g. 110 cm3) by varying the volumes proportionally.
3. Water can be added if needed to maintain the fixed total volume.

21
New cards

Why can the concentration of Ba(OH)2 NOT be determined by mixing it with H2SO4 using the fixed total volume energetics method?

Ba2+(aq) reacts with SO42-(aq) to form BaSO4 precipitate. The enthalpy change of precipitation of BaSO4 contributes to the temperature change of the solution, interfering with the temperature measurements and giving inaccurate results for the enthalpy of neutralisation.

22
New cards

State four sources of error in a combustion experiment using a spirit lamp and metal calorimeter, and the corresponding improvement for each.

1. Incomplete combustion of fuel → increase oxygen supply (e.g. place H2O2/MnO2 beside the setup to generate O2).
2. Rapid evaporation of fuel especially after extinguishing flame → cover the wick with a small cap when not in use.
3. Heat loss from draughts → use a windshield around the apparatus.
4. Thermometer has low precision (1°C divisions) for small temperature changes (5-10°C) → use a thermometer reading to 0.1°C, or a thermocouple/data logger with temperature probe.

23
New cards

How do you calibrate a calorimeter and why is it done?



The calorimeter absorbs some heat from the reaction, which is normally ignored. To account for this, use a fuel with a known enthalpy of combustion (e.g. hexane, delta-Hc = -4163 kJ mol-1) in the same setup. Measure mass of hexane combusted (P - Q) g, amount R mol, and temperature rise (Tf - Ti). Heat capacity of calorimeter: C = (4163 × 10^3 × R) / (Tf - Ti) J K-1. Then use the same calorimeter with the unknown fuel: delta-Hc = -C × delta-T / n, where n = amount of unknown fuel combusted.

24
New cards

Distinguish between a clock reaction and a continuous method in kinetics planning. Give one example of each.



Clock reaction: measure the time taken for a stated observable change to occur. A fixed constant amount of a "clock" species is added; the reaction is timed until this species is used up and the change is seen. Rate is proportional to 1/t (if clock is a product) or Vclock/t (if clock is a reactant). Example: iodine clock using S2O32- to delay appearance of blue-black colour. Continuous method: monitor the concentration (or a measure of it) of a reactant or product at different times throughout the reaction. Example: sampling and titration of H2O2 with KMnO4 at regular time intervals.

25
New cards

In a clock reaction experiment, how do you vary [reactant] while keeping all other conditions constant? Why is water added?



Vary the volume of the reactant of interest across experiments (e.g. 10, 20, 30, 40, 50 cm3). Keep the volumes of all other reagents (other reactant, clock species, indicator) constant across all experiments. Add water to make up the difference so that the total volume of the reaction mixture is the same in every experiment. This ensures that varying the volume of one reactant directly changes its concentration proportionally (V of reactant ∝ [reactant]), since [reactant] = n/V_total and V_total is fixed.

26
New cards

In the iodine clock experiment (Worked Example 10), explain the role of S2O32- and how rate is related to the observations.



S2O32- reacts immediately with any I2 produced in reaction I (S2O82- + 2I- → I2 + 2SO42-) via reaction II (I2 + 2S2O32- → 2I- + S4O62-), so I2 does not accumulate until all S2O32- is consumed. A fixed constant amount of S2O32- is added across all experiments, so the same fixed amount of I2 must be generated before the blue-black colour appears with starch. Since the same amount of I2 is always produced at the endpoint, rate ∝ 1/t. Rate is calculated as 1/t, and since total volume is constant, initial [S2O82-] ∝ V(Na2S2O8).

27
New cards

Describe the three methods to determine the order of reaction in a clock experiment and how each is applied.



Method 1 (inspection): compare pairs of experiments where one volume is doubled. If 1/t stays constant → order 0. If 1/t doubles → order 1. If 1/t quadruples → order 2.

Method 2 (Vnt test): calculate Vt, V2t etc. for all experiments. The quantity that is constant across experiments reveals the order: t constant → order 0; Vt constant → order 1; V2t constant → order 2.

Method 3 (graphical): plot 1/t against V (order 1 gives straight line through origin), or 1/t against V2 (order 2 gives straight line through origin), or 1/t against V (horizontal line = order 0). At least 5 data points needed for a reliable graph.

28
New cards

Describe the sampling, quenching, and titration procedure in Worked Example 11 (H2O2 decomposition with KMnO4). Include: what quenching does, the balanced equation, and how [H2O2] is obtained from the titration.

Procedure:

  1. Mix H2O2 with FeCl3 catalyst in a conical flask. Start stopwatch.

  2. At each time point, pipette a 10.0 cm3 aliquot from the reaction mixture.

  3. Quench by adding 50.0 cm3 of cold dilute H2SO4: the cold acid dilutes and cools the sample, significantly slowing the rate of decomposition so [H2O2] is essentially frozen at that time point. The acid also provides the acidic medium for the KMnO4 titration.

  4. Titrate immediately against 0.02 mol dm-3 KMnO4 until the solution turns from yellow/colourless to pale pink (permanent). Record volume of KMnO4 used.

Balanced equation: 2MnO4-(aq) + 6H+(aq) + 5H2O2(aq) → 2Mn2+(aq) + 8H2O(l) + 5O2(g).

Since mole ratio MnO4- : H2O2 = 2:5, and the aliquot volume is kept constant at 10.0 cm3 each time, V(KMnO4) ∝ [H2O2] remaining. Plot V(KMnO4) against time as a proxy for [H2O2] against time. A straight downward sloping line → zero order; a downward curve with constant half-life → first order.