1/32
Comprehensive vocabulary flashcards covering chemical equilibrium balances, acid-base concepts, quantitative validation, chromatographic separation mechanisms, and mass spectrometry ionization techniques for Chem 227 Exam 2.
Charge Balance
An equation balancing electric charges in an electrolyte solution by setting the sum of all positive molar charges equal to the sum of all negative molar charges, where each molar concentration is multiplied by the magnitude of its ionic charge.
Mass Balance
An equation balancing the different chemical forms of a substance in solution by setting the initial amount added equal to the sum of the equilibrium concentrations of all species derived from it.
Polyprotic Acid
An acid capable of donating multiple hydrogen ions (protons) in sequential dissociation steps.
Polyprotic Base
A base capable of accepting multiple hydrogen ions (protons) in sequential steps.
Henderson-Hasselbalch Equation
An equation relating pH, acid dissociation constant, and the concentrations of conjugate base and acid: pH=pKa+log([acid][base]).
Analyte
The specific chemical constituent of interest being measured or analyzed in a sample.
Matrix
All components of a sample other than the analyte of interest, which can alter instrument response to the analyte.
Calibration Curve
A quantitative method based on the assumption that the response slope is a good estimate of system response and that adding standard solutions does not significantly change overall sample composition.
Standard Addition
A quantitative method that accounts for matrix effects by adding known standard quantities directly to sample aliquots, requiring extrapolation to find the original concentration and permanently altering the sample.
Adsorption Chromatography
A separation mechanism where a solid stationary phase interacts with solutes carried by a liquid or gas mobile phase based on varying surface adsorption affinities.
Partition Chromatography
A separation mechanism where solutes distribute their time between two immiscible phases (liquid-liquid or gas-liquid) according to a partition coefficient K=[solute]mobile[solute]stationary.
Ion-Exchange Chromatography
A separation mechanism where solute ions are separated through electrostatic interactions with charged functional groups on a solid stationary phase resin.
Molecular Exclusion Chromatography
A separation mechanism where solutes are separated strictly by molecular size, where particles larger than stationary phase pores pass through without being retained.
Affinity Chromatography
A separation technique where the stationary phase is functionalized with a specific ligand designed to selectively bind a specific solute, such as in antibody-antigen isolation.

Void Time (tm) / Air Peak
The transit time required for an unretained species (such as air or mobile phase solvent) to travel through a chromatographic column from injector to detector.
Retention Time (tr)
The total elapsed time between sample injection and the arrival of an analyte peak maximum at the detector.
Full Width at Half-Maximum (w1/2)
The horizontal width of a chromatographic peak measured at exactly half of its total peak height.
Theoretical Plate Number (N)
A dimensionless measure of chromatographic column efficiency calculated as N=5.55w1/22tr2, where larger values indicate narrower peaks and better efficiency.
Plate Height (H)
The length of chromatographic column corresponding to one theoretical plate (H=NL); a smaller plate height yields narrower peaks and greater separation efficiency.
Retention Factor (k)
A parameter describing the relative migration rate of an analyte, defined as k=tmtr−tm=tmtr′=time in mobile phasetime in stationary phase.
Chromatographic Resolution
A quantitative measure of the degree of separation between two adjacent peaks, defined as Resolution=w1/2ave0.589Δtr.
Kováts Retention Index (I)
A standardized logarithmic retention index in gas chromatography relating an unknown's retention to surrounding straight-chain alkanes: I=100[n+(N−n)log(tr′(N))−log(tr′(n))log(tr′(unknown))−log(tr′(n))].
Normal-Phase Chromatography
A liquid chromatographic mode employing a polar stationary phase column paired with a less-polar mobile phase.
Reverse-Phase Chromatography
The standard liquid chromatographic mode employing a non-polar stationary phase column paired with a more polar mobile phase.
Isocratic Elution
Chromatographic elution performed using a mobile phase that remains at constant solvent composition throughout the run.
Gradient Elution
Chromatographic elution where the mobile phase solvent composition is varied systematically over time to adjust analyte solubility and improve separation.
Mass Analyzer
The component of a mass spectrometer that disperses and separates gas-phase ions according to their mass-to-charge ratio (m/z).
Base Peak
The most intense peak in a mass spectrum, designated as 100% relative abundance, against which all other peak heights are scaled.
Electron Ionization (EI)
A hard gas-phase ionization technique using high-energy electrons (M+e−→M+∙+2e−) to induce extensive fragmentation for structural fingerprint identification.
Chemical Ionization (CI)
A medium-energy gas-phase ionization technique using an ionized reagent gas (e.g., methane producing CH5+) to gently protonate analytes, forming prominent [M+H]+ ions.
Electrospray Ionization (ESI)
A very soft ionization technique that aerosolizes liquid solutions via high voltage to generate intact, multiply charged gas-phase ions ([M+nH]n+) from biomolecules and LC eluents.
Matrix-Assisted Laser Desorption/Ionization (MALDI)
A soft ionization method where large analytes co-crystallized with an organic matrix on a solid target are desorbed by laser pulses to form predominantly intact, singly charged [M+H]+ ions.
Inductively Coupled Plasma Mass Spectrometry (ICP-MS)
A very hard elemental mass spectrometry technique using high-temperature argon plasma to atomize and ionize liquid aerosol samples, eliminating molecular structure for trace metal and isotope quantification.