CELL BIO WEEK 11

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/67

encourage image

There's no tags or description

Looks like no tags are added yet.

68 Terms

1
New cards

NIH 3T3 cells

An immortal mouse cell line that spontaneously immortalized and has a stable growth rate.

2
New cards

Immortal (immortalized) cell line

A population of cells from a multicellular organism that, because of mutation, keeps going through the cell cycle and dividing, when normally such cells would not proliferate indefinitely. The mutations can occur naturally or be induced by experimenters.

3
New cards

Immortal cell lines vs. stem cells

Stem cells divide indefinitely as part of the organism’s normal developmental program; immortal cell lines divide indefinitely because of mutations. NIH 3T3 cells are not stem cells.

4
New cards

Adherent cells

Cells that grow attached to the surface of the culture vessel, so they must be detached (here with trypsin/EDTA) to be passaged. [definition not in manual]

5
New cards

Confluent / percent confluence

How much of the culture surface is covered by cells; a confluent culture covers the whole surface. You record percent confluence before passaging. [definition not in manual]

6
New cards

Ethanol fixation

Ethanol is a non-additive precipitant fixative: it fixes cell components by dehydration and precipitation, without forming covalent bonds. How well it fixes depends on how much water is present.

7
New cards

What happens to lipids in ethanol fixation, and why does it matter for PI?

Lipids are not preserved, and some dissolve in the ethanol, which makes the plasma membrane permeable to PI. PI can then stain all the double-stranded nucleic acids in the cells.

8
New cards

Can PI enter living cells?

No. An intact cell membrane is not permeable to PI; a permeable membrane is a sign of cell death or apoptosis, so in a growing culture PI stains only dead cells.

9
New cards

Propidium iodide (PI)

A fluorescent dye that binds double-stranded nucleic acids, both DNA and RNA. It is carcinogenic, so wear gloves.

10
New cards

Structure of PI

It resembles ethidium bromide: three joined, conjugated six-membered rings. The molecule is flat.

<p>It resembles ethidium bromide: three joined, conjugated six-membered rings. The molecule is flat.</p>
11
New cards

How does PI bind DNA and dsRNA?

By intercalation: the flat molecule inserts itself between the stacked base pairs of dsDNA and dsRNA.

12
New cards

RNase

A nuclease that degrades both double-stranded and single-stranded RNA into small fragments; small dsRNA pieces under 10 base pairs become single-stranded.

13
New cards

Why add RNase while staining with PI?

It removes all double-stranded RNA, so PI binds DNA specifically. The PI fluorescence of each cell then measures its DNA content.

14
New cards

Why doesn’t the free, unbound PI around the cells fluoresce much?

Free PI absorbs the excitation light, but solvent water quenches most of its excited-state energy. PI intercalated in DNA sits in a hydrophobic, water-free environment, so it emits a photon as fluorescence.

15
New cards

How is DNA content measured in this lab?

PI-stained, RNase-treated cells are photographed by fluorescence microscopy, and FIJI measures the total fluorescence (integrated density) of each nucleus.

16
New cards

DNA content through the cell cycle

G1: 2N (diploid). S: between 2N and 4N as DNA is replicated. G2 and M: 4N. [not in manual]

17
New cards

How does integrated density tell you a cell’s cell-cycle stage?

Integrated density is the total PI fluorescence of the nucleus, which reflects its DNA content: nuclei with about twice the G1 value are in G2/M, and those in between are in S. [the G1/S/G2 values are not in manual]

18
New cards

Why must every fluorescence photo use the same settings?

So the data are consistent between images: same camera zoom and same camera illumination setting, and on the AxioLab A.1 the same microscope fluorescence intensity.

19
New cards

Why must the cells be in sharp focus?

FIJI can’t threshold out-of-focus cells, so blurry images can’t be analyzed.

20
New cards

Photos needed for the FIJI analysis

Several fields of PI-stained cells under fluorescence at 200X with at least 40 sharply focused cells, plus one brightfield photo of the scale bar at the same magnification and phone zoom.

21
New cards

Microscopes and camera mount for PI imaging

Zeiss AxioLab A.1 or Zeiss Primostar fluorescence microscopes, with your phone in a Gosky mount.

22
New cards

PI stain: first spin of the ethanol-fixed cells

Centrifuge at 800 x g (1,000 rpm in the IEC centrifuge) for 3 minutes. Mark the tube at 0.5 and 0.1 mL, remove ethanol down to 500 µL, and gently resuspend by flicking.

23
New cards

PI stain: washing in PBS + BSA

While vortexing at low speed, add 4.5 mL PBS + BSA dropwise (final volume 5.0 mL), mix by inversion, spin at 800 x g for 3 minutes, and withdraw the supernatant down to 0.1 mL.

24
New cards

PBS + BSA

Phosphate-buffered saline plus 0.5 mg/mL bovine serum albumin.

25
New cards

PI stain: counting the cells

Resuspend by pipetting 50 µL up and down at least 10 times without bubbles, load 10 µL into a hemocytometer, and count under phase contrast at 100X (Axiostar set up in Koehler illumination during the spin).

26
New cards

Target cell concentration for PI staining

1.0 × 10^6 cells/mL. Dilute with PBS + BSA; if you have fewer, re-centrifuge and remove 50 µL of supernatant.

27
New cards

How much PI staining solution (with RNase)?

11 µL per 100 µL of cell suspension (5.5 µL if you have 50 µL), in an Eppendorf tube.

28
New cards

PI staining time and conditions

At least 20 minutes at room temperature, protected from light.

29
New cards

Making the PI slide

Resuspend by gentle flicking, put 5 µL on a clean slide, add a coverslip, seal the edges with nail polish, and let it dry in the fume hood with the hood lights off before going near a microscope.

30
New cards

What is Fiji?

“Fiji Is Just ImageJ”: free ImageJ image-analysis software (fiji.sc). The toolbar’s title bar reads “(Fiji Is Just) ImageJ.”

31
New cards

What if Fiji’s main menu bar doesn’t show up?

Select the Fiji toolbar window and the main menu bar should appear.

32
New cards

Lookup table (LUT) button

A button on the Fiji toolbar that changes the colors used to display an image (also under Image > Lookup Tables). Hovering over any toolbar button shows what it does in the bottom-left of the toolbar.

<p>A button on the Fiji toolbar that changes the colors used to display an image (also under Image &gt; Lookup Tables). Hovering over any toolbar button shows what it does in the bottom-left of the toolbar.</p>
33
New cards

.czi files and metadata

Carl Zeiss Image files from a professional Zeiss microscope. Proprietary formats like this contain extra information; “Display metadata” shows details such as the lasers and filters used.

34
New cards

When does the Bio-Formats Import Options dialog appear?

When you open a proprietary microscope file such as a .czi, not an ordinary image like a JPEG.

35
New cards

Two Bio-Formats import options you must turn on

Split channels (splits the image into its individual colors) and View stack with: Hyperstack (imports it in a useful format).

<p>Split channels (splits the image into its individual colors) and View stack with: Hyperstack (imports it in a useful format).</p>
36
New cards

The three channels in the FIJI video’s example image

Green: glucocorticoid receptor, a transcription factor, labeled with an antibody. Blue: DAPI, a DNA dye that marks the nucleus. Red: an endosomal protein that binds the green protein.

<p>Green: glucocorticoid receptor, a transcription factor, labeled with an antibody. Blue: DAPI, a DNA dye that marks the nucleus. Red: an endosomal protein that binds the green protein.</p>
37
New cards

DAPI

A DNA dye that marks the nucleus (the blue channel in the FIJI video).

38
New cards

Can split channels be put back together?

Yes, they can be merged back into one image (Image > Color > Merge Channels).

39
New cards

What does Invert LUT do?

Swaps the display so dark colors become light and light colors become dark, giving every color scheme a second look. The underlying image is the same.

<p>Swaps the display so dark colors become light and light colors become dark, giving every color scheme a second look. The underlying image is the same.</p>
40
New cards

How do you save your image for the workbook?

File > Save As > Jpeg.

41
New cards

Why open the scale bar image along with the cell image?

To set the scale: the image starts out measured in pixels (shown at the top left of the window), and it must be changed to microns to get real area measurements of the nuclei.

42
New cards

Two toolbar tools used for the measurements

The straight line tool (to measure the scale bar) and the wand (tracing) tool (to select individual nuclei).

43
New cards

First step before thresholding

Convert the image to grayscale: Image > Type > 8-bit.

<p>Convert the image to grayscale: Image &gt; Type &gt; 8-bit.</p>
44
New cards

Why convert to 8-bit grayscale before thresholding?

The computer can only use the intensity information properly in grayscale. Once the image is a single dimension of intensity, it can threshold against it to find the nuclei.

45
New cards

How do you open the threshold tool?

Image > Adjust > Threshold.

46
New cards

Threshold methods compared in the Thresholding video

Default (IsoData) didn’t select the nuclei well at first; Huang looked similar to Default; Intermodes worked well for this image. You can also drag the threshold sliders to adjust any method.

<p>Default (IsoData) didn’t select the nuclei well at first; Huang looked similar to Default; Intermodes worked well for this image. You can also drag the threshold sliders to adjust any method.</p>
47
New cards

Display options in the Threshold dialog

You can change how the threshold is shown (for example Red or Over/Under) and flip the background with the Dark background box. The video uses Red, with the background shown red and the nuclei left white.

48
New cards

What do you save after thresholding?

Save at least your first thresholded image (File > Save As > Jpeg) to show you did it.

49
New cards

Setting the scale, step 1

Pick the straight line tool, drag a line across the whole scale bar, and measure it (Analyze > Measure, or Cmd+M / Ctrl+M) to get the scale bar’s length in pixels.

<p>Pick the straight line tool, drag a line across the whole scale bar, and measure it (Analyze &gt; Measure, or Cmd+M / Ctrl+M) to get the scale bar’s length in pixels.</p>
50
New cards

Setting the scale, step 2

Analyze > Set Scale: “Distance in pixels” is already filled in from your line. Enter the known distance, which you calculate yourself from the magnification as described in the workbook, and change the unit of length from pixel to micron. [the video’s example uses 400X; this lab’s photos are taken at 200X]

<p>Analyze &gt; Set Scale: “Distance in pixels” is already filled in from your line. Enter the known distance, which you calculate yourself from the magnification as described in the workbook, and change the unit of length from pixel to micron. [the video’s example uses 400X; this lab’s photos are taken at 200X]</p>
51
New cards

How can you tell the scale has been set?

The top-left of the image window shows microns instead of pixels.

52
New cards

Which three measurements do you record for each nucleus?

Area, mean gray value and integrated density (chosen in Analyze > Set Measurements).

<p>Area, mean gray value and integrated density (chosen in Analyze &gt; Set Measurements).</p>
53
New cards

How do you measure one nucleus?

Click it with the wand (tracing) tool to select it, then Analyze > Measure (Cmd+M); the values appear in the Results table.

<p>Click it with the wand (tracing) tool to select it, then Analyze &gt; Measure (Cmd+M); the values appear in the Results table.</p>
54
New cards

Why must you avoid clusters of nuclei?

A cluster gives a falsely high integrated density and area. In the video, a cluster measured 848 area and 159,907 integrated density, versus about 440–478 and 78,000–85,000 for single nuclei.

<p>A cluster gives a falsely high integrated density and area. In the video, a cluster measured 848 area and 159,907 integrated density, versus about 440–478 and 78,000–85,000 for single nuclei.</p>
55
New cards

How many cells do you measure, and what goes in the lab report?

At least 40 individual cells, avoiding clusters. Include the table of area, mean gray value and integrated density.

56
New cards

Mean gray value vs. integrated density

Mean gray value: the average pixel brightness in the selection. Integrated density: area × mean gray value, the object’s total signal. [not in manual]

57
New cards

Hood rules for passaging

Work only on the solid surface; spray 70% ethanol on everything that goes in, including gloved hands; have all materials inside before you start; don’t open media or cells until ready; keep your hands in the hood.

58
New cards

Materials for passaging

Pipets, tips, pipettors, two waste beakers (solids and liquids), a 15 mL conical tube, cells in a 25 cm² flask, DMEM+, trypsin/EDTA, sterile PBS and BCS, with a 70% alcohol spray outside the hood.

59
New cards

Passaging: before removing the medium

Scan the whole flask on the inverted phase contrast microscope and record percent confluence, then pour the expired medium into the waste beaker without disturbing the cells.

60
New cards

Passaging: PBS rinse

Pipette 4 mL sterile PBS into the flask at the neck, tilt to rinse the cells, and pour it out without disturbing them.

61
New cards

Passaging: trypsin/EDTA step

Add 1 mL trypsin/EDTA and tilt until it covers the whole surface. Check every 2 minutes on the inverted microscope; when the cells round up and detach, tilt until no attached cells remain and they float.

62
New cards

Passaging: after the cells detach

Add 4 mL PBS and 0.500 mL BCS, pipette it over the surface 3–4 times to rinse off remaining cells, and put the ~5 mL suspension into a 15 mL conical tube.

63
New cards

Passaging: spin and resuspend

Centrifuge at 1,200 rpm for 5 min (1,000 x g in the IEC). In the hood, pour off the supernatant, add 1 mL PBS, finger-vortex until there are no clumps, and keep on ice.

64
New cards

Why finger-vortex before pipetting cells into the wells?

Cells left undisturbed for several minutes sink to the bottom of the 15 mL tube.

65
New cards

6-well plate setup for the apoptosis experiment

A cohort of three groups shares a plate: 1X, 2X, 3X (experimental) on top and 1C, 2C, 3C (controls) below. Each well gets 1.4 × 10^4 cells in 2 mL DMEM+.

<p>A cohort of three groups shares a plate: 1X, 2X, 3X (experimental) on top and 1C, 2C, 3C (controls) below. Each well gets 1.4 × 10^4 cells in 2 mL DMEM+.</p>
66
New cards

Labeling the 6-well plate

Write your bench number on one side of the plate cover; don’t label the tops of the wells, because you look through them.

67
New cards

What happens to the 6-well plate next week?

Apoptosis will be induced and observed directly by 200X phase contrast on the inverted microscopes.

68
New cards

Is a new 25 cm² flask started this week?

No.