What is the effect of increasing the distance between the X-ray source and the image receptor?
No effect on energy; Reduce intensity
T/ F Characteristic x-rays have a range of energies.
False
Ultrasound imaging uses:
High-frequency sound waves
What is the primary function of the x-ray tube?
accelerate electrons from the cathode to anode
Bremsstrahlung radiation is produced when:
High-speed electrons are decelerated near the nucleus of target atoms.
Hardware computer components include all of the following except:
Bits
All of the following are subject factors when assessing image quality, except:
Object position
Photometry is the science of the:
response of the human eye to visible light
A/an ___________ is an unwanted pattern on an image that does not represent anatomy.
Artifact
Increasing filtration _____________ the average energy of an x-ray beam and x-ray intensity _______________.
increases; decreases
Which body habitus is small, frail, sometimes emaciated, and often seen in elderly patients?
Asthenic
T/F Bremsstrahlung x-rays have a range of energies.
True
Scatter radiation is:
Radiation that changes direction after interacting with matter
What is increased by added filtration?
"Effective" Energy
Surface-Guided Radiation Therapy (SGRT) primarily uses:
Optical cameras to monitor a patient's external surface
Noise in an image refers to:
Unwanted random variations that reduce image quality
The number of x-rays in useful beam is known as ____________.
X-ray intensity
What is the purpose of image inversion in medical imaging?
Reversing grayscale values—black becomes white and white becomes black
Filters for x-ray beams are typically made or:
Aluminum
Bremsstrahlung X-ray energy is ________ proportional to its wavelength.
inversely
T/F Heat production also increases indirectly with increasing kVp (at least in the diagnostic range).
False
Which component of the x-ray tube is the positive electrode and target for electrons?
Anode
Which body habitus is typically big in frame and often overweight?
Hypersthenic
Cone-Beam Computed Tomography (CBCT) is commonly used for:
Image-guided patient positioning and localization
Pixels are:
The smallest elements of a digital image
T/F Radiolucent appears darker on a radiograph.
True
What is the primary benefit of using subtraction in Digital Subtraction Angiography (DSA)?
Improves image contrast by removing background structures
X-ray intensity is __________________ to the square of the distance from the source.
Inversely proportional
Magnetic Resonance Imaging (MRI) primarily uses:
Magnetic fields and radiofrequency pulses
In medical imaging, noise refers to:
deterioration of the radiographic image
Computed Radiography (CR) uses:
Imaging plates that are digitally processed
T/ F Characteristic x-rays have precisely fixed energies.
True
What is the purpose of defining a Region of Interest (ROI) in quantitative imaging?s
To measure the average pixel value for analysis
PACS primary purpose is to:
store and share images electronically
Adaptation of computer technology to mimic the human mind in cognitive activities is _______________.
Artificial Intelligence
Which of the following medical image techniques uses infrared sensors to capture surface anatomy:
SGRT
If the kVp are increased, then the electron kinetic energy will ____________.
increase
What is the result of increasing filtration in the X-ray beam?
Increase energy; Reduce intensity
Why is pixel shift used during image postprocessing?
To correct for patient motion and align images accurately
Scotopic vision is related to:
night vision
The primary purpose of SGRT is to:
Improve patient positioning and monitor patient motion during treatment
The cathode in an x-ray tube:
Serves as the negative electrode and source of electrons
T/F Sharpness of Image Detail describes the ability to see the detail on the image.
False
All of the following are types of filtration, except:
Compounding filters
Process by which very high-energy x-rays can escape interaction with electrons and the nuclear electric field and can be absorbed directly by the nucleus is:
Photodisintegration
In multislice CT, the protocol parameter collimation is:
A combination of beam collimation and detector array size
T/F Image artifacts can typically be minimized through proper alignment.
False
What x-rays are produced by the slowing down of an electron by the target atom's nuclear field?
Bremsstrahlung X-rays
T/F Square law is a corollary to the inverse square law.
True
The cones are:
used for photopic vision
Amorphous silicon is commonly found in:
Flat-panel detectors
Gadolinium is commonly used as:
An MRI contrast agent
Interfraction uncertainties refer to:
Variations occurring between treatment fractions that affect accuracy
When assessing image quality, which of the following would be considered a geometric factor?
Image Blur
Which of the following are considered X-ray interactions occurring with (body) matter? (Select 2 that apply.)
Photoelectrical absorption and Compton Scattering
Absorption of an x-ray by ionization is:
Photoelectric Effect
Which body habitus is described as "strong, active," and represents the average patient?
Sthenic
T/F When selecting technique factors, keep exposure time as high as possible to ensure penetrability.
False
What characteristic of radiographic quality is improved by using reduced x-ray exposure time?
Motion blur
X-ray beam hardening is:
increases the # of high energy x-rays in the beam by removing the lower-energy nonpenetrating x-rays.
A primary advantage of MR-Linac imaging is its ability to:
Visualize soft tissues during treatment and adapt radiation delivery in real time.
What is the result on the image when an anatomic structure is not equally magnified?
Distortion
What is the magnification factor?
Image Size/Object Size
What is the primary purpose of x-ray beam filtration?
to filter low energy x-rays
Ionization occurs when:
An atom gains or loses electrons
Hardware is the physical components of the system that include various input and output devices.
True
A detector array consists of:
Multiple detector elements arranged in a pattern
In imaging, density generally refers to:
The degree of image blackness or brightness
In the Photoelectric Effect:
The photon is completely absorbed by an inner-shell electron
What is Magnetic Resonance Linear Accelerator (MR-Linac) Imaging?
A radiation therapy system that combines MRI with a linear accelerator for real-time image guidance
If the mAs increase, the number of projectile electrons racing towards the target _____________.
increase
Detectors are used to:
Measure and capture radiation information
T/F Software is the computer programs that tell the hardware what to do and how to store and manipulate data.
True
How does magnification enhance image interpretation
By improving visualization and spatial resolution
Contrast resolution refers to
ability to distinguish between and to image similar tissues
Photon interacts with an outer shell atomic electron and the photon becomes redirected, or scattered, from its original path without a change in energy is
Coherent Scattering
The purpose of Digital Imaging and Communications in Medicine (DICOM) is to:
transfer images
What is the primary purpose of annotation in medical imaging
To label and identify structures within the image
Which body habitus is characterized by a thin but healthy appearance
Hyposthenic
Magnification factor =
SID/SOD
Distortion is a misrepresentation of object size & shape on the image (T or F)
true
The rods are used principally for which of the following?
dim vision
Onboard imaging systems are primarily used for
Treatment verification and patient alignment
What is the effect of increasing mAs on the X-ray beam?
No effect on energy; Increase intensity
Image Receptor sometimes referred to a cassette. (T or F )
F
The Inverse Square Law states that radiation intensity:
Decreases proportionally to the square of the distance from the source
T/F Air, when used as a contrast agent, is considered a positive contrast agent.
False
The Spiral Pitch Ratio in CT is the:
Table movement per rotation divided by beam width
Which of the following best refers to the digital imaging process?
Flat-panel detector
Spatial resolution refers to:
The ability to distinguish small objects that are close together
Attenuation is:
The reduction in X-ray intensity that results from absorption and scattering.
High penetrability = High ___________ rays
quality
PET/CT combines:
Functional PET imaging with anatomical CT imaging
Differential absorption increases as the ___ is reduced.
kVp
The bothersome magnification can be minimized by using:
Correct answer:
larger SID
T/F Radiopaque appears gray on a radiograph
False
T/F: The probability of Compton scattering depends on the atomic number of the target atom.
False
X-ray quality is the output intensity of an x-ray imagining system
False
Voxels are best described as the three-dimensional equivalent of:
pixels
MRI Safety Zones are designed to:
Organize access and improve safety around MRI systems