New cards

Report the incident, and evaluate the work fairly

A contractor offers you a sum of money in exchange for approving the work immediately. As a Master Plumber, what will be your action?

2
New cards

Not Clarifying the financial interest in the contract

A Master Plumber Secretly receive a commission from a distributor after securing the item for the client’s house. What is the ethical consequence of this situation?

3
New cards





Install backflow prevention device.

To reduce installation cost, the client wants to connect the potable water supply to an industrial mixing tank. what will be the design recommendation?

4
New cards

25mm

Lavatories and other fixtures with effective openings not greater than 13mm in diameter not affected by the side.

5
New cards

38mm

Sinks, laundry trays, gooseneck bath faucets and other fixtures with effective openings not greater the 19mm in diameter not affected by the side.

6
New cards

51mm

Over rim bath fillers and other fixtures with effective openings not greater than 25mm in diameter not affected by the side

7
New cards

Two (2) times diameter of effective opening

Effective openings not greater than 25mm not affected by the side

8
New cards

38mm

Lavatories and other fixtures with effective openings not greater than 13mm in diameter affected by the side.

9
New cards

57mm

Sinks, laundry trays, gooseneck bath faucets and other fixtures with effective openings not greater the 19mm in diameter affected by the side.

10
New cards

76mm

Over rim bath fillers and other fixtures with effective openings not greater than 25mm in diameter affected by the side.

11
New cards

Three (3) times diameter of effective opening

Effective openings not greater than 25mm affected by the side

12
New cards

Approved airgap fitting

A domestic dishwasher drain shall first connect to a/an?

13
New cards

2

DFU of Bathtub

14
New cards

Ball Cock

A valve opened and closed by fall and rise, respectively of an attached ball floating on the surface of the liquid

15
New cards

2.1m

Vertical vent pipes installed in a roof used for other purposes shall extend a minimum of ____ above such roof.

16
New cards

0.3m

Horizontal clearance of vent pipe above the roof from any vertical surface nearby.

17
New cards

3m

horizontal distance of vent opening from any openable window, door opening, air intake or vent shaft.

18
New cards

0.9m

vertical distance above vent opening from any openable window, door opening, air intake or vent shaft.

19
New cards

140-degree Faren Hight

The maximum temperature of water that can be discharged under pressure directly into any part of drainage system.

20
New cards

Locate the gas main above grade at the point of entrance into the building

A gas pipping is designed to be installed under a building with no ventilation. As the master plumber what should be your recommendation?