1/35
Looks like no tags are added yet.
electrochemistry
branch of analytical chemistry that uses electrical measurements of chemical systems for analytical purposes
redox reaction
involves transfer of electrons from one species to another species
oxidation
loss of electrons
reduction
gain of electrons
oxidizing agent/oxidant
takes electrons from another substance and becomes reduced
reducing agent/reductant
gives electrons to another susbtance and is oxidized in the process
assigning oxidation states
each atom in a pure element has an oxidation number of 0
a monoatomic ion has an oxidation number equal to ion charge
in compounds, halogens have an oxidation number of -1 unless Cl, Br, and I are combined with O or F
in compounds, O has an oxidation number of -2 except in compounds containig peroxide (O2 2-) or superoxide (O2-), oxygen has an oxidation number of -1 or -1/2
when combined with nonmetals, H is an assigned an oxidation number of +1. with metals, H has an oxidation number of -1
the sum of the oxidation number for all atoms in a species is equal to the overall charge on the species
balancing redox reaction steps
write half reactions
balance all elements except O and H
in acidic solution, balance O by adding H2O on opposite sides, then balance H with H+
balance the charges on each side by adding e- to the left for R and to the right for Ox
balance the electrons
add equations to give overall balanced equation
check that elements and charges on both sides of equation add up
electric charge (Q)
quantity of electricity; measured in units of coulombs (C) and a signle electron/proton has a charge of 1.602 × 10-19 C
relationship between charge and moles
Q = n * mol * F
where n = unit charges per molecule and F = faraday constant = 9.649 × 104 C/mol
electric current
quantity of charge flowing each second through a circuit; unit of current is the amphere (A), which represents the flow of one coulomb of charge person past a point in a circuit
electric potential difference (E)
work required between two points when a unit charge moves from one point to the other; measured in volts
voltage, work, and free energy
when a charge Q moves through potential difference E, the work required to move charge to a higher energy or the work done by charge moving to a lower energy is
|Work| = E * Q where E = voltage and Q = coulombs
work has the dimensions of energy: joules (J) and 1 V = 1 J/C
when is heat (q) positive?
when it flows from the surroundings to the system
when is heat (q) negative?
when it flows from the system to the surrounding
when is work (w) positive?
when it is done on a system
when is work (w) negative?
when it is done on the surroundings
gibbs free energy of reaction
deltaG = n*F*E
E= potential difference (volts)
F= faraday constant (C/mol)
n = unit charges per molecule
power (P)
work done over time; measured in watts (W); 1 W = J/s
P = E*I
ohm’s law
current is directly proportional to the potential difference across a circuit and inversely proportional to the resistance of the circuit
I = E/R
greater voltage
more current will flow
greater resistance
less current will flow
galvanic cell
uses a spontaneous chemical reaction to generate electricity; oxidizing and reducing agents are physically separated and electrons are forced to flow through a wire to go from one reactant to the other
anode
the electrode at which oxidation occurs
cathode
electrode at which reduction occurs
nernst equation
relates the voltatge of the cell, E, to the activities of the reactants and products
E = E* - 0.05916/n log (aD)d / (ac)c where Q = (aD)d/(aC)c
nernst equation for a complete reaction
write reduction half-reactions for both half-cells and find E* for each. multiply the half-reactions as necessary so they both contain the same number of electrons.
write a nernst equation for the right half-cell, which is attached to the positive terminal of the voltmeter. this is E+
write a nernst equation for the left half-cell, which is attached to the negative terminal of the voltameter. this is E-
find the net cell voltage by subtraction: E = E+ - E-
write the net cell reaction by subtracting the left half-reaction from the right half-reaction
what happens if E is positive
electrons flow through the wire from the left-hand electrode to the right hand electrode, -deltaG
what happens if E is negative
electrons flow through the wire from the right-hand electrode to the left-hand electrode. +deltaG
E at equilibrium
E (not E*) = 0; when a battery dies, the chemicals inside have reacted equilibrium and the battery voltage dropped to 0V
potentiometry
an analytical method in which an electric potential difference of a cell is measured
electroactive species
an analyte that can donate or accept electrons at an electrically conductive electrode
indicator electrode (working electrode)
electrode that responds to analyte activity
reference electrode
maintains a fixed (reference) potential
ideal features of reference electrode
constant half-cell potential, no drift in potential over time, no potential charge when current flows, potential unaffected by sample components
silver-