1/23
Looks like no tags are added yet.
Name | Mastery | Learn | Test | Matching | Spaced | Call with Kai | Chat |
|---|
No analytics yet
Send a link to your students to track their progress
reagent grade chemicals
meet purity requirements by ACS
trace metal grade chemicals
reagents have extremely low impurities, important for trace analysis
volumetric analysis
procedures that measure volume of reagents needed to react with analyte
titration
increments of reagent solution added until the reaction b/w analyte and titrant is complete
titrant
reagent solution, usually delivered from buret
analyte
quantity calculated from amount of titrant consumed in reaction
requirements for titrations
reaction must have large equilibrium constant
reaction must proceed rapidly
each increment of titrant should be completely and quickly consumed
analyte should be completely used up
equivalence point
quantity of added titrant is exact amount necessary for stoichiometric reaction with the analyte (ideal theoretical result based on stoichiometry)
end point
actual measurement, marked by sudden change in physical property of the solution.
End point does not = equivalence point because extra titrant, beyond what is needed to react is required to see the purple color
indicator
compound with physical property (usually color) that changes abruptly near the equivalence point.
titration error
difference between end point and equivalence point
blank titration
carry out same titration procedure on similar solution without the analyte
provides estimate of titration error
subtract blank titration volume from volume observed in analytical titration
primary standard
pure and stable enough to be used directly after weighing.
99.99% pure
should not decompose during storage
stable when dried by heat or vacuum
stoichiometry of reaction with titrant must be known
standardization
prep a titrant with approx the desired concentration and use it to titrate a primary standard
method can be used to determine conc. of the titrant
validity of analytical result ultimately depends on knowing the conc. of the primary standard
direct titration
add titrant to analyte until reaction is complete
back titration
add known excess of one standard reagent to analyte
titrate excess with second standard reagent
when is back titration useful?
when endpoint of back titration is clearer than direct titration
when an excess of the first reagent is required for complete reaction with analyte
gravimetric titration
measures the mass of titrant solution delivered in each increment
titration curves
shows how conc. of reactant varies as titrant is added
what is sharpness of endpoint influenced by?
concentration of analyte and titrant
size of solubility product (Ksp)