1/104
Looks like no tags are added yet.
Computed Tomography (CT)
Which imaging modality uses an X-ray tube and a detector array to collect anatomical data from the patient, which is then reconstructed into an image displayed on a computer monitor?
Godfrey Hounsfield
Who developed the first CT scanner in 1970 while working as a physicist and engineer for Electro Musical Industries (EMI)?
In 1972
In what year was the first CT head performed?
Alan Cormack
Which medical physicist developed the mathematical algorithms used to perform CT imaging?
Dr. Robert Ledley
Who created the first whole-body CT scanner in 1974?
The Nobel Peace Prize in physics
In 1979, what did Godfrey Hounsfield and Alan Cormack win?
Computed Axial Tomography (CAT)
What was the old terminology used for CT?
Translation
What term refers to the period during which the X-ray source and detector rotate around the patient, known as the scan time?
Rotate (Index to next location)
What term refers to the movement of the source and detectors into position for the next translation?
By scanning the patient
How is CT accomplished?
First Generation CT
Which generation of CT had a pencil-thin beam and could only perform CT heads?
One detector
How many detectors did the first-generation CT scanner have?
Translate/rotate, 180 translations
What kind of movement did first-generation CT scanners use? How many were there?
4.5 minutes per image and 5 minutes for reconstruction
How long did it take first-generation CT scanners to complete a patient scan and reconstruct the image for display?
Eliminated air interfaces
What did the water bag eliminate in first-generation CT scanners?
Second Generation CT
Which generation of CT scanners introduced the fan beam and was the first to be used for whole-body imaging?
30 detectors
How many detectors did the second-generation CT use?
15-30 seconds per image
How long did it take for the second-generation CT to produce images?
Scatter
What was increased in second-generation CT scanners as a result of using a fan beam?
Bow tie filter
What device was developed for second-generation CT scanners to reduce scatter, featuring a narrower center and increased edge filtration?
Third Generation CT
Which generation of CT scanners uses 960 detectors and rotates only the X-ray tube and detector?
1-12 seconds per image
How long does the third-generation CT take to scan patients?
Ring artifacts
In third-generation CT scanners, what artifact appears if a single detector in the array fails?
Fourth Generation CT
Which generation of CT scanners uses 4800 detectors in a ring and is limited by computer processing time?
Rotate/stationary (tube rotates)
What kind of movement do fourth-generation CT scanners use?
1/2-10 seconds per image
How long does it take for fourth-generation CT to scan patients?
Slip rings
Which electromechanical device, invented in the 1990s, uses brushes and rings to conduct electricity and allows the CT tube to rotate continuously while the patient moves through the gantry, enabling the collection of volumetric data in a single breath hold?
Replaced the cables
What did slip rings replace on the X-ray tubes in CT?
- helical
- motion
- scan
- contrast media
- thinner
- spatial resolution
- slip ring
Volume Scanners
- Spiral or __________ motion
- Reduced ____________
- Reduced _________ time
- Decreased amount of ____________ _________ needed
- ____________ slices
- better ___________ _______________
- Eliminated the ________ _________ artifact
Spiral/Helical CT
Which type of CT scanner uses a spinning tube and detectors, creating a spiral appearance as the table moves through the gantry to produce the spiral effect?
Pitch
What refers to the distance a patient travels through the gantry in the length of time the tube moves 360°?
Ratio of tube movement to section thickness
The pitch in CT is the ratio of what?
- Indicates overlap of radiation and a greater patient dose
- Slow
- Spatial resolution increases
- What does a pitch less than one indicate?
- Is the patient moving fast or slow through the gantry?
- What happens to spatial resolution?
- Indicates a gap between slices and a lower patient dose
- Fast
- Spatial resolution decreases
- What does a pitch greater than one indicate?
- Is the patient moving fast or slow through the gantry?
- What happens to spatial resolution?
Increases pitch
What does faster travel and increased space between slices do to the pitch?
Decreases patient dose and spatial resolution
What does increased pitch do to patient dose and spatial resolution?
Gantry, computer, and operating console
What are the three main components of a CT system?
Operating system
What component of the CT system contains a keyboard, mouse, and monitors?
For operation
What is the main operating console used for?
Protocol
What are the parameters for each CT exam that include slice thickness, technique, field of view, and display settings?
120 kVp, 400 mA, and 0.5-5 mm slice thickness
What is the average protocol used for CT scanners?
Z-axis
What refers to how far the CT couch/tables travel and is controlled by the operator?
Post processing the images
On the operating console, what is the second console responsible for?
The radiologist/physician
On the operating console, who is the possible third console for?
Computer
What component of the CT system has a large computing capacity and has an algorithm that can provide 250,000 calculations at once?
Reconstruction Time
What refers to the end of the scan time to when the image appears on the screen?
Operating System Software
What is responsible for the CT system's computer hardware, such as turning the computer on, warming up the tube, and doing the QC?
Application System Software
What component of the CT system is responsible for data processing, image reconstruction, and post-processing?
Gantry
What component of the CT system includes the tube, detectors, collimators, a light to center by, a high voltage generator, and a patient support couch?
30°
To what degree can the CT gantry tilt?
20-34
The CT gantry includes a ____-_____ inches diameter aperature
- 8 million heat units
- 10,000 rpm
- 120 kVp, 400 mA, 60 sec exposure time
- How much heat can the CT gantry tube withstand?
- At what speed does the CT gantry's tube anode rotate?
- What represents the average of the technical factors used for the CT gantry tube?
Scintillation Detector Array
Which component of the CT gantry absorbs approximately 90% of the radiation exiting the patient and converts it first into light and then into an electrical signal?
Analog-to-digital converter (ADC)
What converts an electrical signal into a digital signal to be displayed on a monitor and sent to PACS?
Lower patient dose, faster time, and lower signal-to-noise ratio
What are the three benefits of the CT gantry's scintillation detector array?
Pre-Patient Collimator
Which collimator on the CT gantry reduces the size of the radiation field, which reduces slice thickness and controls patient dose?
Post-Patient Collimation or Pre-Detector Collimation
Which collimator on the CT gantry reduces scatter reaching the detectors and also helps with slice thickness?
Patient support couch
What is made of carbon graphite, moves through the CT gantry smoothly, and supports the patient's weight?
- Low atomic number
- 450-600 lbs
- What is the atomic number like for a CT couch/table?
- How much weight can the CT couch/table support?
High Voltage Generator
What component of the CT gantry is small enough to mount on the X-ray tube?
Matrix (2D)
What is made up of rows and columns of pixels (picture elements)?
512 x 512 (262,144 pixels)
What is the typical matrix size used in CT?
Field of View
What refers to the diameter of each image?
Pixel size = FOV/matrix
What is the pixel size formula?
Voxel (3D)
In CT, what refers to the height, width, and depth of a pixel?
Voxel size = pixel size x slice thickness
What is the voxel size formula?
The depth of the pixel
In CT, what does the slice thickness equal?
Attenuation Coefficient
What refers to the amount of radiation attenuated?
- 0
- +1000 to +3000
- -1000
- What is the CT #/Hounsfield # of water?
- What is the CT#/Hounsfield # of bone?
- What is the CT#/Hounsfield # of air?
Filtered black projection
What is the mathematical function for the reconstruction of CT images into multiple planes?
Window Width
What refers to the range of CT numbers (shades of gray)?
Window Level
What refers to the center of the window width (brightness)?
Multiplanar Reconstruction (MPR)
What is the stacking of axial scans to create images in other planes?
Multi-Slice Scanners
What is the use of parallel bands of detectors with helical scanning?
Spatial resolution
What term describes imaging of structures with high contrast, such as bone against soft tissue?
Contrast resolution, 1%
What term describes imaging of structures with low contrast (as low as __% can be detected), such as liver against spleen?
Noise
What refers to the graininess on a CT image?
- Partial volume averaging
- Ring (3rd gen detector error)
- Streak (motion)
- Star (metal)
What are the four artifacts that can be seen on CT images?
Five pen test
Which QC test is used to assess the linearity of a CT scanner, and requires the water to be consistently calibrated to zero each time it is performed?
The same CT number
When evaluating the uniformity of a CT scanner, what should uniform objects display?
Scan field of view (SFOV)
What refers to the area of the patient exposed to radiation in CT?
Display field of view (DFOV)
What refers to the area displayed on the reconstructed image in CT that is zoomed?
Informed consent
When doing basic procedures in CT, what kind of consent should be obtained from the patient?
Scanogram (topogram)
What refers to the scout image in CT that can be done AP or lateral?
10
A CT scout image can equal ____ chest x-rays on a radiation level
- Oral (low density barium, 1%-3%)
- IV (iodine)
- Rectal (water soluble iodine)
What are the three ways contrast media can be given in CT, and what are the three types of contrast media?
- Viewed one slice at a time and from the feet up
- Into different planes
- In 2 WW settings
- On optical disks, printed on laser film, or stored in PACS
- How are CT images viewed?
- How can CT images be reconstructed for viewing?
- How many window width settings can CT images be viewed?
- Where are CT images stored?
- CT virtual endoscopy
- CT angiography
- Cardiac CT
- Percutaneous biopsy
- Percutaneous drainage
What are the four specialized procedures used in CT?
CT virtual endoscopy
Which specialized procedure in CT fills the patient with air?
CT angiography
Which specialized procedure in CT injects iodine into the vessels?
Cardiac CT
Which specialized procedure in CT is linked to an ECG and matches the patient's heartbeat?
3D CT
Which type of CT reconstructs data into 3-dimensional images?
You don't have to inject into the femoral artery
Although 3D angiography CT exposes patients to more radiation than conventional angiography, what is its primary advantage?
600 chest x-rays
How many chest X-rays are equivalent to one 3D angiography CT?
Air
What contrast media are used in virtual colonoscopies?
higher, diagnostic, 40%-67%
CT has a ___________ dose than ______________ procedures and makes up _____%-_____ %of radiation exposure of all procedures
5000 mrad/exam
Although radiation dose varies with each CT procedure, what is the typical mrad/exam?
CT techs
Although equipment vendors have reduced radiation exposure, who is primarily responsible for dose reduction?
Lead shielding
What should not be used within the scan field of CT?
Bismuth Shield
What type of shield is used in CT that minimizes patient dose to radiosensitive organs but increases noise on the image?