Chapter 34: Tomography and Digital Tomosynthesis

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/56

encourage image

There's no tags or description

Looks like no tags are added yet.

57 Terms

1
New cards

What is the main purpose of tomography?

To overcome superimposition of anatomical structures by demonstrating a selected plane in focus.

2
New cards

In what year was traditional tomography developed?

1921.

3
New cards

What anatomical plane does traditional tomography primarily demonstrate?

The coronal plane.

4
New cards

What imaging modality largely replaced traditional tomography?

CT scanning.

5
New cards

Which clinical study may still use traditional tomography?

Urographic studies.

6
New cards

What are four alternative names for tomography?

Planigraphy, stratigraphy, laminography, and body section radiography.

7
New cards

What are the three elements of a tomographic system?

X-ray tube, object, and image receptor.

8
New cards

How do the X-ray tube and image receptor move in conventional tomography?

Synchronously in opposite (contralateral) directions.

9
New cards

What is tomographic blur?

Purposeful streaking or smearing of anatomy outside the focal plane.

10
New cards

What happens to blur as exposure amplitude increases?

Blur increases.

11
New cards

What happens to blur as an object moves farther from the fulcrum?

Blur increases.

12
New cards

How does greater distance from the image receptor affect blur?

Blur increases.

13
New cards

How does tube travel orientation influence blur?

Blur increases as tube travel approaches perpendicularity to the structure.

14
New cards

What is the fulcrum?

The pivot point around which the tube and image receptor move.

15
New cards

What does the fulcrum determine?

The focal plane or section in focus.

16
New cards

Where should the anatomy of interest be positioned for conventional tomography?

At the fulcrum level / focal plane

17
New cards

What happens to objects in the fulcrum plane?

They remain sharp with high spatial resolution and do not appear to move.

18
New cards

What happens to structures far from the fulcrum?

They blur because of relative motion.

19
New cards

What is exposure amplitude?

Distance of X-ray tube travel during exposure.

20
New cards

What is exposure angle?

Angle or arc of the X-ray beam determined by exposure amplitude.

21
New cards

What is section thickness?

Width of the focal plane displayed in focus.

22
New cards

Which factor controls section thickness?

Exposure angle.

23
New cards

What happens to section thickness as exposure angle increases?

Section thickness decreases.

24
New cards

What is the relationship between exposure amplitude and section thickness?

Inverse: greater amplitude yields thinner sections.

25
New cards

What is section interval?

Distance between successive fulcrum levels.

26
New cards

How many focal planes are exposed in a traditional tomographic study?

Multiple focal planes.

27
New cards

How large should section interval changes be relative to section thickness?

They should not exceed section thickness.

28
New cards

What extra sections are typically needed around the anatomy of interest?

At least one full section above and one below.

29
New cards

What is another name for digital tomosynthesis?

Digital radiographic tomography.

30
New cards

How does digital tomosynthesis simulate tomographic sections?

Through post-acquisition processing and reconstruction algorithms.

31
New cards

What detector type is required for digital tomosynthesis?

A flat-panel detector.

32
New cards

What does digital tomosynthesis combine?

Digital image capture and processing with tube/detector motion.

33
New cards

How is tomosynthesis distinguished from CT?

Tomosynthesis is a separate process; CT is described as axial section acquisition.

34
New cards

Approximately how many exposures form a tomosynthesis image database at minimum?

At least approximately 10 exposures.

35
New cards

What can be done with tomosynthesis images after acquisition?

Post-process and reformat them in different planes without additional patient exposure.

36
New cards

How is tomosynthesis spatial resolution described?

Excellent spatial resolution.

37
New cards

How does the lecture compare tomosynthesis dose with single-image mammography?

Comparable dose.

38
New cards

What breast-imaging status does the lecture attribute to digital tomosynthesis?

It is becoming the gold standard for mammography.

39
New cards

What resolution and dose advantage does the lecture associate with breast tomosynthesis?

Higher spatial resolution with the same or lower dose.

40
New cards

Why is exposure time important in tomography?

It must match the tube exposure amplitude.

41
New cards

What exposure times are listed for complex tomographic systems?

3-6 seconds.

42
New cards

What mA setting is typical for dedicated tomographic units?

A very low mA setting, less than 100 mA.

43
New cards

What is zonography?

Narrow-angle tomography.

44
New cards

What exposure angle defines zonography?

Less than 10 degrees.

45
New cards

What section thickness is produced by narrow-angle tomography?

Thick sections.

46
New cards

When is wide-angle tomography used?

When more detail is needed.

47
New cards

Which alternative is often more useful than wide-angle tomography?

CT.

48
New cards

What is another name for panoramic tomography?

Panorex.

49
New cards

Where is panoramic tomography most popular?

Dental applications.

50
New cards

Which bones can panoramic tomography help image?

Mandible and facial bones.

51
New cards

Why do structures outside the focal plane appear smeared in tomography?

Opposing tube/receptor motion causes off-plane structures to shift relative to the receptor.

52
New cards

What would be the effect of choosing a smaller exposure angle?

A thicker section is displayed in focus.

53
New cards

What would be the effect of moving the fulcrum to a different depth?

A different anatomical section becomes sharp.

54
New cards

Why should adjacent tomographic section intervals not exceed section thickness?

To avoid gaps between the imaged focal sections.

55
New cards

What does the tomosynthesis diagram illustrate?

Different reconstructed planes can focus different object depths from a set of projection exposures.

56
New cards

What does the movement diagram show?

Tube and receptor moving in opposite directions around a stationary fulcrum.

57
New cards

What does the panoramic diagram show?

Tube and receptor travel around the jaw to produce a panoramic dental image.