Industrial Automation, Digital Systems, and Instrumentation Review

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/27

flashcard set

Earn XP

Description and Tags

Vocabulary practice flashcards covering digital logic circuits, PLCs, pneumatics, electromagnetic interference coupling, industrial bus protocols (HART, Fieldbus), and UPS power protection based on lecture notes.

28 Terms

1
New cards

Asynchronous Inputs (J-K Flip-Flop)

Inputs—specifically Preset (PRE) and Clear (CLR)—that change the state of the output QQ immediately, regardless of the clock (CLK) signal.

2
New cards

Preset (PRE)

An asynchronous active input on a flip-flop that forces the output QQ to logic 1 (high) regardless of the clock.

3
New cards

Clear (CLR)

An asynchronous active input on a flip-flop that forces the output QQ to logic 0 (low) regardless of the clock.

4
New cards

Full Adder (from Half Adders)

A logic circuit constructed using two half adders and one OR gate, where the sum output comes from the second half adder and both carry outputs are combined through the OR gate to generate CoutC_{\text{out}}.

5
New cards

D-Type Flip-Flop Configuration

A J-K flip-flop configuration where the data input DD connects directly to JJ and through an inverter to KK, making output QQ follow DD on the clock transition.

6
New cards

Asynchronous Counter (Ripple Counter)

A multi-bit binary counter formed by J-K flip-flops with JJ and KK tied high (logic 1), where the external clock drives only the LSB stage and the QQ output of each stage clocks the subsequent stage.

7
New cards

Counter-Type ADC

An analog-to-digital converter architecture that utilizes a binary counter, a DAC, and a comparator to determine digital values corresponding to an analog input.

8
New cards

PLC Scan Cycle

The sequential 3-step operating routine of a PLC consisting of: 1. Read Inputs (take snapshot to input memory), 2. Execute the program (top to bottom, left to right), and 3. Write to outputs (update output cards from the memory register at the END instruction).

9
New cards

Read Inputs (PLC Scan Step 1)

The phase where the PLC takes a snapshot of the current state of all connected input devices and saves it into memory before program execution begins.

10
New cards

Execute Program (PLC Scan Step 2)

The phase where the PLC executes user logic from top to bottom and left to right, sequentially updating the output memory register based on the input snapshot.

11
New cards

Write to Outputs (PLC Scan Step 3)

The final phase of the scan cycle occurring at the END instruction, where the processed states stored in the output memory register are physically written to the output cards.

12
New cards

PLC Safety Device Wiring Rule

The requirement that safety devices (such as E-stops and safety switches) must be hardwired into a dedicated safety circuit or safety relay rather than standard PLC inputs, ensuring fail-safe operation if the PLC loses power or malfunctions.

13
New cards

Instruction List (IL)

A text-based programming language for PLCs using mnemonic instructions such as LD (Load), AND, ANI (AND NOT), OR, ORI (OR NOT), OUT, and END to represent ladder rungs.

14
New cards

Pneumatic Cylinder Force Calculation

The determination of working force using Force=Pressure×Area\text{Force} = \text{Pressure} \times \text{Area}; for a 150 mm150\text{ mm} cylinder at 5 bar5\text{ bar} (500,000 Pa500{,}000\text{ Pa}), theoretical force is 8835 N8835\text{ N}, reduced by a 1.51.5 loss factor to 5890 N5890\text{ N} (supporting a mass of 600.4 kg600.4\text{ kg} under gravity 9.81 m/s29.81\text{ m/s}^2).

15
New cards

5/2 Double Solenoid Valve

A directional control valve with 5 ports and 2 spool positions actuated by two separate electrical solenoids, used to control double-acting cylinders with speed control on both strokes.

16
New cards

Capacitive Coupling

Interference generated when two conductors in close proximity with a potential difference act as capacitor plates (separated by air as the dielectric), causing a voltage change on one conductor to induce an unwanted voltage on the other; mitigated using shielded cable.

17
New cards

Inductive Coupling

Interference caused by current-carrying conductors creating changing magnetic fields that induce unwanted voltages in adjacent signal cables; mitigated using twisted pair wiring.

18
New cards

Impedance Coupling

Interference occurring when two or more electrical circuits share a common return wire or earth connection, causing the return current of one circuit to produce an unwanted interfering voltage across the shared impedance; mitigated by using separate return wires.

19
New cards

Talker

A communication device configured to send data to other devices over an instrumentation or bus network (e.g., a digital voltmeter or smart instrument).

20
New cards

Listener

A communication device configured to receive data transmitted from another device across a network (e.g., a printer or SCADA system).

21
New cards

Fieldbus Benefits

The five core advantages of fieldbus architectures: Time efficiency (reduced install/startup time), Interoperability (multi-vendor compatibility), Flexibility (easy expansion), Diagnostics (online monitoring), and Intelligence (local device processing).

22
New cards

HART Protocol

Highway Addressable Remote Transducer protocol; an instrumentation standard that superimposes digital communication signals onto an existing 4–20 mA4\text{--}20\text{ mA} analog loop without interrupting the analog signal.

23
New cards

Frequency Shift Keying (FSK) in HART

The modulation technique based on the Bell 202 standard used by HART, encoding digital logic using two distinct audio frequencies: 1200 Hz1200\text{ Hz} for Logic '1' (mark) and 2200 Hz2200\text{ Hz} for Logic '0' (space).

24
New cards

Uninterruptible Power Supply (UPS)

A backup power system used with computing and control hardware to prevent data loss, permit safe shutdown, protect equipment against surges/spikes/fluctuations, and maintain operation during brief outages.

25
New cards

Blackout

A total, complete loss of electrical mains power supply.

26
New cards

Voltage Sag

A temporary short-duration drop in the nominal supply voltage.

27
New cards

Voltage Surge

A short-term transient increase in the supply voltage above nominal operating levels.

28
New cards

Voltage Spike

An instantaneous, sharp burst in voltage that is significantly shorter in duration than a voltage surge.