What does ohms mean?
Resistance to electron flow.
What information is needed when replacing a contactor?
Number of poles, FLA, and coil voltage.
What does FLA stand for?
Full Load Amps.
What does RES stand for on a contactor?
Resistive Amps.
What does RLA stand for?
Rated Load Amps.
What does LRA stand for?
Locked Rotor Amps.
What component is RLA used for?
Compressor.
What is another term for LRA?
Inrush current.
What information is needed when replacing a condenser fan motor?
RPM, HP, and amps.
Where does the set screw go?
On the flat side of the shaft.
When replacing the motor, what must you also replace?
Capacitor.
When can you leave the wires out of the top of the unit?
Never.
Before replacing a condenser fan motor, what do you need to measure?
The diameter of the shaft.
How do you cut the shaft of a universal motor?
With a hacksaw, reciprocating saw, or angle grinder.
Where do the two brown wires go on a universal motor?
To each side of the new capacitor.
The same leg that powers the run winding powers what?
C on the capacitor.
What does the C on a dual run capacitor stand for?
Capacitor power in, same as run.
Where do the common motor wires go?
Opposite leg as run.
When does common of the motor go to the capacitor?
Never.
The fan terminal of a dual run capacitor wires to what?
Fan motor start winding.
The herm terminal of a dual run capacitor wires to what?
Compressor start winding.
Before checking a capacitor, what steps do you need to take?
Turn off power, check for no voltage, discharge with a 20k ohm 5 watt resistor, remove wires, then check with a meter.
A run capacitor is usually made of what?
Metal.
A start capacitor is usually made of what?
Plastic.
How should a run capacitor be mounted?
Metal to metal to metal and upright when possible.
Can you replace a dual run capacitor with two individual capacitors?
Yes.
Can a 370 VAC capacitor be replaced with a 440 VAC capacitor?
Yes.
Can a 440 VAC capacitor be replaced with a 370 VAC capacitor?
No. It must be replaced with a 440 VAC capacitor.
A start capacitor must also be wired with a:
potential relay
How must a start capacitor and its components be wired?
5 = common, 2 = start, 1 = run
Which symbol represents a capacitor?
—| (—
Capacitance is measured in:
Microfarads
A compressor has voltage but is not running. The problem could be:
Tripped internal thermal overload.
Between which two terminals on the compressor would have the most resistance?
Start-Run
ohming out a compressor, you measure 8 ohms from R-S, OL from C-S, and OL from C-R. What is the problem?
tripped internal thermal overload
The number one replaced part of an HVAC system is:
Capacitor
The second most replaced part of an HVAC system is:
Contactor
The third most replaced part of an HVAC system is:
Condenser fan
When a motor is pulling more current than it’s rated for, this is called:
Overamping
What tool can be used to check the insulation of windings?
Megohmeter