Sensitometry and H & D curves exposures ppt

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/55

encourage image

There's no tags or description

Looks like no tags are added yet.

56 Terms

1
New cards

Nonlinear (curved)

The response of a film as a function of X-ray exposure is _________

2
New cards

H and D curve

The curve describing OD versus the logarithm (base 10) of exposure is called the ______________

3
New cards

Sigmoid (s)

The H and D curve has a ________ shape

4
New cards

x-axis

On the H and D curve the exposure is on the

5
New cards

Y-axis

On the H and D curve the density is on the

6
New cards

Hurter and driffield

H&D means?

7
New cards

(Film) characteristic, D log E curve, sensitometric curve

Other names for H and D

8
New cards

Sensitometer (penetrometer), densitometer, graph paper,

Equipment needed for sensitometry

9
New cards

Sensitometer

Device which produces steps of gray tones on a film

10
New cards

Penetrometer

Aluminum step wedge

11
New cards

Densitimeter

Device which measure amount of density on a radiograph

12
New cards

Steps of sensitometry

1. Expose film with sensitometer (or penetrometer) to produce a Control Strip of densities

2. Process film

3. Measure each density step with a densitometer

4. Plot the density on a graph

5. Connect the dots (forms a curve)

13
New cards

Toe

Represents low exposure and density; B + F portion of the curve from 0 to 0.25

14
New cards

Body

(Slope; straight- line portion; gamma) portion of the curve from 0.25 to 2.5 density

15
New cards

Body

Measures the usable densities

- indicates overall gray scale (contrast) of the film

16
New cards

Shoulder

Portion of the curve from 2.5 to maximum density (aka D-max)

17
New cards

Shoulder

Measures the unusable densities (blackest portion) on the radiograph

18
New cards

Speed point

That point on the H & D curve where a density of OD 1.0 + B+F is achieved

19
New cards

Contrast

Between OD 0.25 + B+F and OD 2.5 + B+F

20
New cards

Negative recorder

X-ray film is a ______________ - increased light (or X-ray) exposure causes the developed film to become darker

21
New cards

Densitometer

Degree of darkness is quantified by the optical density measured with a ____________

22
New cards

Logarithms

Density values are in ___________

23
New cards

OD = Log10 (light incident (Io)/ light transmitted (It))

Transmittance and OD are defined as

24
New cards

Perfectly clear (does not exist)

T value of 1.0000 and OD value of 0 =

25
New cards

Unexposed film (base + fog)

T value of 0.7760 and OD value of 0.11 =

26
New cards

Medium gray

T value of 0.1000 and OD value of 1 =

27
New cards

Dark

T value of 0.0100 and OD value of 2 =

28
New cards

Very dark; requires hot lamp

T value of 0.0010 and OD value of 3 =

29
New cards

Maximum OD used in medical radiography

T value of 0.00025 and OD value of 3.6 =

30
New cards

Slope (straight line portion)

Contrast of a radiographic film is related to the _________________ of the H& D curve

31
New cards

Higher contrast

Regions of a more vertical slope have a

32
New cards

Lower contrast

Regions of a more horizontal slope. (Toe and shoulder) have

33
New cards

Average gradient

A single number , which defines the overall contrast of a given type of radiographic film, is the

34
New cards

+/- 0.10

Contrast values must not fluctuate more than __________ from baseline

35
New cards

Contrast number

The _______________ is produced as a result of subtracting density values that are logarithms

36
New cards

Short, high

If straight line on H and D curve is more vertical = _______ scale of contrast, ______ contrast

37
New cards

Long, low

If stingy line on H and D curve is more horizontal= ______ scale contrast, ______ contrast

38
New cards

Greatest contrast

Striking differences between black and white areas; very few grays ( high scale)

- H&D curve= more vertical slope

39
New cards

Lowest contrast

Little differences between black and white areas; many shades of gray; (long scale)

H&D curve= more horizontal slope

40
New cards

Narrow

If straight line portion on H & D curve is more vertical the latitude is_________ or high contrast

41
New cards

Wide

If straight line portion on H and D curve is more horizontal the latitude is _______ or low contrast

42
New cards

Film speed

Recorded detail on H& D curve is base on ___________

43
New cards

Steeper curve

A __________ on H and D curve = poorer recorded detail

44
New cards

Shallow curve

A __________ on H and D curve = better recorded detail

45
New cards

Closest to left

On H and D curve the curve ______ has the highest speed and thickest emulsion film

46
New cards

Reciprocity law

The relationship between exposure and OD should remain constant regardless of the exposure rate; mAs1= mAs2

47
New cards

Reciprocity law failure

For very long or very short exposures, and exposure rate dependency between exposure and OD is observes, and this is called ________________

48
New cards

Sensitometric testing

Performed daily on every processor and ensured consistent processing of films by monitoring: speed, contrast, base plus fog (B+F)

49
New cards

Left

Less patient dose film= film to the ______

50
New cards

Left

Less technique needed= film to the ______

51
New cards

Left

Thickest emulsion film = film to the _______

52
New cards

Right

Best recorded detail film= film to the _______: more horizontal (shallow) slope

53
New cards

Horizontal

Widest latitude film = more ________ slope

54
New cards

Vertical

Extended development time = more _________ slope

55
New cards

More horizontal slope

Low contrast, widest latitude film; more grays

56
New cards

More vertical slope

High contrast; narrow latitude; less gray tones; extended development time; greatest contrast