1/55
Looks like no tags are added yet.
Nonlinear (curved)
The response of a film as a function of X-ray exposure is _________
H and D curve
The curve describing OD versus the logarithm (base 10) of exposure is called the ______________
Sigmoid (s)
The H and D curve has a ________ shape
x-axis
On the H and D curve the exposure is on the
Y-axis
On the H and D curve the density is on the
Hurter and driffield
H&D means?
(Film) characteristic, D log E curve, sensitometric curve
Other names for H and D
Sensitometer (penetrometer), densitometer, graph paper,
Equipment needed for sensitometry
Sensitometer
Device which produces steps of gray tones on a film
Penetrometer
Aluminum step wedge
Densitimeter
Device which measure amount of density on a radiograph
Steps of sensitometry
1. Expose film with sensitometer (or penetrometer) to produce a Control Strip of densities
2. Process film
3. Measure each density step with a densitometer
4. Plot the density on a graph
5. Connect the dots (forms a curve)
Toe
Represents low exposure and density; B + F portion of the curve from 0 to 0.25
Body
(Slope; straight- line portion; gamma) portion of the curve from 0.25 to 2.5 density
Body
Measures the usable densities
- indicates overall gray scale (contrast) of the film
Shoulder
Portion of the curve from 2.5 to maximum density (aka D-max)
Shoulder
Measures the unusable densities (blackest portion) on the radiograph
Speed point
That point on the H & D curve where a density of OD 1.0 + B+F is achieved
Contrast
Between OD 0.25 + B+F and OD 2.5 + B+F
Negative recorder
X-ray film is a ______________ - increased light (or X-ray) exposure causes the developed film to become darker
Densitometer
Degree of darkness is quantified by the optical density measured with a ____________
Logarithms
Density values are in ___________
OD = Log10 (light incident (Io)/ light transmitted (It))
Transmittance and OD are defined as
Perfectly clear (does not exist)
T value of 1.0000 and OD value of 0 =
Unexposed film (base + fog)
T value of 0.7760 and OD value of 0.11 =
Medium gray
T value of 0.1000 and OD value of 1 =
Dark
T value of 0.0100 and OD value of 2 =
Very dark; requires hot lamp
T value of 0.0010 and OD value of 3 =
Maximum OD used in medical radiography
T value of 0.00025 and OD value of 3.6 =
Slope (straight line portion)
Contrast of a radiographic film is related to the _________________ of the H& D curve
Higher contrast
Regions of a more vertical slope have a
Lower contrast
Regions of a more horizontal slope. (Toe and shoulder) have
Average gradient
A single number , which defines the overall contrast of a given type of radiographic film, is the
+/- 0.10
Contrast values must not fluctuate more than __________ from baseline
Contrast number
The _______________ is produced as a result of subtracting density values that are logarithms
Short, high
If straight line on H and D curve is more vertical = _______ scale of contrast, ______ contrast
Long, low
If stingy line on H and D curve is more horizontal= ______ scale contrast, ______ contrast
Greatest contrast
Striking differences between black and white areas; very few grays ( high scale)
- H&D curve= more vertical slope
Lowest contrast
Little differences between black and white areas; many shades of gray; (long scale)
H&D curve= more horizontal slope
Narrow
If straight line portion on H & D curve is more vertical the latitude is_________ or high contrast
Wide
If straight line portion on H and D curve is more horizontal the latitude is _______ or low contrast
Film speed
Recorded detail on H& D curve is base on ___________
Steeper curve
A __________ on H and D curve = poorer recorded detail
Shallow curve
A __________ on H and D curve = better recorded detail
Closest to left
On H and D curve the curve ______ has the highest speed and thickest emulsion film
Reciprocity law
The relationship between exposure and OD should remain constant regardless of the exposure rate; mAs1= mAs2
Reciprocity law failure
For very long or very short exposures, and exposure rate dependency between exposure and OD is observes, and this is called ________________
Sensitometric testing
Performed daily on every processor and ensured consistent processing of films by monitoring: speed, contrast, base plus fog (B+F)
Left
Less patient dose film= film to the ______
Left
Less technique needed= film to the ______
Left
Thickest emulsion film = film to the _______
Right
Best recorded detail film= film to the _______: more horizontal (shallow) slope
Horizontal
Widest latitude film = more ________ slope
Vertical
Extended development time = more _________ slope
More horizontal slope
Low contrast, widest latitude film; more grays
More vertical slope
High contrast; narrow latitude; less gray tones; extended development time; greatest contrast