Who discovered x-rays?
Roentgen
Who wrote the first dental text and introduced the bite-wing technique?
Raper
Who exposed the first dental radiograph in the U.S. (skull)?
Morton
Who used paralleling technique in practical dental radiography?
McCormack
Who exposed the first dental radiograph in the U.S. (living patient)?
Kells
Who introduced long-cone paralleling technique?
Fitzgerald
Who developed the first x-ray tube?
Coolidge
The collimator ______
restricts the size and shape of the x ray beam
is a solid piece of aluminum
is fitted within the copper stem beneath the molybdenum cup
is always round
restricts the size and shape of the x ray beam
On some dental x-ray machines, only the ____ can be altered; the other parameters are preset by the manufacturer.
kilovoltage
exposure time
PID length
milliamperage
exposure time
Which of the following are considered to be semicritical instruments?
the exposure button
receptor holding devices
the x ray control panel
the lead apron
receptor holding devices
In dental imaging, no_________ are used
critical instruments
semicritical instruments
noncritical instruments
critical instruments
A beam alignment device can be used to help the dental radiographer position the PID in relation to the _______ and the receptor
collimator
control panel
tooth
extension arm
tooth
Which of the following should you do prior to taking x rays to protect your patient from radiation exposure?
proper film processing
a thyroid collar
a lead apron
proper prescribing of radiographs
proper prescribing of radiographs
Through the use of dental images, the dental radiographer can detect ________ that cannot be detected clinically.
diseases
lesions
conditions of teeth and bones
all of the above
all of the above
In order to avoid the primary beam while taking dental images, you should stand at a ____-degree to ____-degree angle to the beam.
90; 135
An oral examination limits the practitioner to knowledge of what is seen clinically. Dental images allow the practitioner to see many conditions that are not apparent clinically.
the first statement is true; the second is false
both are false
both are true
the first statement is false; second is true
both are true
Which of the following statements is true of the receptor holder?
it requires the patient to stabilize the receptor in the mouth
it is used to align an extraoral dental x ray receptor
it is required when using the intraoral bisecting technique
it is required when using the intraoral paralleling technique
it is required when using the intraoral paralleling technique
The _____________ allow(s) for positioning of the tubehead.
extension arm
exposure button
control panel
control devices
extension arm
A _________ eliminates the need for the patient to stabilize the receptor
beam alignment device
PID
control panel
receptor holder
receptor holder
_______ regulates the manufacture and installation of dental x ray equipment
municipal government
federal government
state government
local government
federal government
You are 36 years old. What is your communicative occupational does recommended by the national Council on radiation protection and measurement (NCRP)
180 millirems
360 mSv
180 mSv
360 millirems
360 mSv
According to the recommendations (2003) of the national Council on Radiation Protection and Measurements, the current MPD for occupationally exposed persons is ______/year
5000 rem
5.0 rem
50 rem
500 millirem
5.0 rem
Which of the following types of PIDs produces scatter radiation
square
rectangular
round
conical
conical
Which type of PID would be most effective in reducing patient exposure?
an 8 inch rectangular PID
conical
a 16 inch round PID
a 16 inch rectangular PID
a 16 inch rectangular PID
A circular collimator produces a cone-shaped beam that is _______ inches in diameter
1.25
2.75
5.0
2.75
A rectangular collimator:
restricts the beam 3 times more than a circular collimator
decreases patient exposure considerably
is considerably larger than a size 2 intraoral receptor
restricts the beam less than a circular collimator
decreases patient exposure considerably
The ALARA concept states that all radiation must be kept:
as low as reasonably achievable
Critical instruments are defined as instruments:
that contact but do not penetrate bone
devices that do not come in contact with mucous membranes
that contact but do not penetrate soft tissue
that are used to penetrate soft tissue or bone
that are used to penetrate soft tissue or bone
State and federal laws require that dental x-ray machines operating above 70 kVp have a minimum total (inherent plus added filtration) of ____ mm of aluminum filtration.
1.5
2.5
5.0
2.0
2.5
Another term for infection control is ______, which means the absence of pathogens, or disease causing microorganisms
antifective
asepsis
antibiotic
antiseptic
asepsis
Pathogens are
bacteria but not viruses
viruses but not bacteria
microorganisms capable of causing disease
any microorganism
microorganisms capable of causing disease
Antiseptic is:
the absence of pathogens, or disease causing microorganisms
the use of a chemical or physical procedure to inhibit or destroy pathogens
the act of sterilizing
a substance that inhibits the growth of bacteria
a substance that inhibits the growth of bacteria
Added filtration in the dental x ray tubehead
refers to the placement of tungsten discs in the path of the x ray beam between the collimator and the tubehead seal
filters our shorter wavelength x rays from the x ray beam
results in a lower energy beam
results in a more penetrating useful beam
results in a more penetrating useful beam
Label
1 - filament and electron cloud
2 - focal spot on tungsten target
3 - glass envelope
4 - vacuum
5 - copper stem
6 - anode (+)
7 - useful x ray beam
8 - tube window
9 - cathode (-)
10 - electronic focusing cup

Label
1 - filament and electron cloud
2 - electronic focusing cup, cathode (-)
3 - x ray tube
4 - Focal spot on tungsten target
5 - copper stem, anode (+)
6 - insulating oil
7 - unleaded glass window
8 - lead collimator
9 - PID
10 - aluminum disks
11 - tubehead seal

A detector that is used to capture the dental image
sensor
pixel
direct digital imaging
digital radiography
sensor
An image receptor found in the intraoral sensor
pixel
charge-coupled device (CCD)
storage phosphor imaging
digitize
charge-coupled device (CCD)
A form of indirect digital imaging in which the image is recorded on phosphor-coated plates and then placed into an electronic processor, where a laser scans the plate and produces an image on a computer screen
storage phosphor imaging
direct digital imaging
digital radiography
sensor
storage phosphor imaging
To convert an image into digital form that, in turn, can be processed by a computer
digital subtraction
sensor
digitize
pixel
digitize
A method of obtaining a digital image in which an intraoral sensor is exposed to x-rays to capture an image that can be viewed on a computer monitor
digital radiography
direct digital imaging
charge-coupling device
pixel
direct digital imaging
a discrete unit of information; a picture element
sensor
digitize
charge-coupled device
pixel
pixel
a method of reversing the gray scale as a digital image is viewed
direct digital imaging
digital subtraction
digital radiography
sensor
digital subtraction
a filmless imaging system; a method of capturing an image using a sensor, breaking the image into electronic pieces, and presenting and storing the image using a computer
digital radiography
pixel
digital subtraction
storage phosphor imaging
digital radiography
True or False. In digital imaging, the term used to describe the picture that is produced is radiograph
false
True or False. Digital imaging requires more x-radiation than conventional radiography
false
True or False. The x-radiation source used in most digital imaging systems is a conventional dental x-ray unit
true
True or False. Compared with film emulsion, the pixels used in digital imaging are structured in an orderly arrangement
true
True or False. All intraoral sensors can be heat-sterilized after use
false
True or False. The preferred exposure method for intraoral digital imaging is the paralleling technique
true
True or False. One advantage of a digital imaging system is the superior gray-scale resolution that results
true
True or False. Digital subtraction is an advantage in digital imaging because distration background information is eliminated from the image
true
True or False. The manipulation of the origingal digital images can be considered a legal issue
true
Digital imaging was introduced to dentistry in
1968
1990
1987
1997
1987
Digital imaging can be used for:
Detecting conditions of teeth and surrounding structures
Evaluating the growth and development of jaws
Confirmation of suspected disease
All of the above
all of the above
Digital imaging requires less radiation than does conventional radiography because:
The sensor is larger
The sensor is more sensitive to x-rays
The exposure time is increased
The pixels sense transmitted light quickly
the sensor is more sensitive to xrays
The image receptor found in the intraoral sensor is termed
CCD
pixel
Semiconductor chip
Software
CCD
Digital imaging systems can be used for which images:
Bite-wing
Panoramic
Cephalometric
All of the above
all of the above
All of the following are advantages of digital imaging except:
Digital subtraction
The ability to enhance the image
Size of the intraoral sensor
Patient education
size of the intraoral sensor
Why is an increased target-receptor distance required in the paralleling technique?
to avoid image magnification
to avoid distortion
to reduce scatter radiation
to improve receptor placement
to avoid image magnification
Which describes the relationship of the central ray to the receptor in the paralleling technique?
20 degrees to the long axis of the tooth
90 degrees to the receptor and long axis of the tooth
75 degrees to the long axis of the tooth
15 degrees to the receptor and the long axis of the tooth
90 degrees to the receptor and long axis of the tooth
Which of the following about the lack of parallelism between the receptor and the long axis of the tooth is correct.
If the lack of parallelism is greater than 30 degrees, the image is generally acceptable.
If the lack of parallelism is less than 20 degrees, the image is generally acceptable.
If the lack of parallelism is less than 50 degrees, the image is generally acceptable.
If the lack of parallelism is greater than 50 degrees, the image is generally acceptable.
If the lack of parallelism is less than 20 degrees, the image is generally acceptable.
Which are advantages of the paralleling technique?
1. increased accuracy
2. simplicity of use
3. ease of duplication
4. ease of receptor placement
1, 2, 3
True or false: The advantages of the paralleling technique outweigh the disadvantages.
true
State the five rules of the paralleling technique.
Receptor placement, receptor position, vertical angulation, horizontal angulation, receptor exposure
too much vertical angulation results in images that are
elongated
foreshortened
overlapped
none of the above
foreshortened
Too little vertical angulation results in images that are
elongated
foreshortened
overlapped
none of the above
elongated
incorrect horizontal angulation results in images that are
elongated
foreshortened
overlapped
none of the above
overlapped
Which occurs can occur with the bitewing technique?
elongation
overlapped contacts
cone-cut
phalangioma
overlapped and cone-cut
Which errors can occur with the bisecting technique?
elongation
overlapped contacts
cone-cut
phalangioma
elongation
you have been using a dental x ray machine that has a 4 inch PID. your new machine has an 8 inch PID. given that all exposure factors remain the same, according to the inverse square law, the resultant beam would be _________ as intense:
one quarter
four times
half
twice
one quarter
when kilovolt is increased, a:
higher energy x ray beam with decreased penetrating ability results
higher energy x ray beam with increased penetrating ability results
lower energy x ray beam with increased penetrating ability results
lower energy x ray beam with decreased penetrating ability results
higher energy x ray beam with increased penetrating ability results
(1) Density is the overall darkness or blackness of a dental image. (2) When the kilovoltage is increased while other exposure factors remain constant, the resultant image exhibits a decreased density and appears lighter.
the first statement is true; the second is false
the first statement is false; second is true
both are true
both are false
the first statement is true; second is false
mA regulates the _______ of electrons produced at the cathode filament:
quality
power
speed
quantity
quantity
In regard to increasing density:
An increase in either kVp or mA will increase density
an increase in kV will increase density, but an increase in mA will not increase density
an increase in mA will increase density, but an increase in kV will not increase density
neither an increase in kV nor an increase in mA will increase density
an increase in either kV or mA will increase density
Aluminum filters:
remove more penetrating x rays from the beam
removie high energy x-rays from the beam
reduce the intensity of the x ray beam
decrease the mean penetrating ability of the x ray beam
reduce the intensity of the x ray beam
aluminum filters are used to remove ________ energy, _________ wavelength x rays:
high; longer
high; shorter
low; longer
low; shorter
low; longer
which of the following changes will increase x ray beam intensity:
decreasing the kilovoltage
decreasing the exposure time
decreasing the mA
decreasing the source-to-film distance
decreasing the source-to-film distance
(1) As kilovoltage, milliamperage, and time increase, x-ray beam intensity decreases. (2) As distance and filtration increase, the intensity of x-ray beam increases.
the first statement is true; second is false
the first statement is false; second is true
both are true
both are false
both are false
when contrasted with the use of 70 kV for dental x rays, the use of 60 kV produces:
less penetrating dental x rays with longer wavelength
more penetrating dental x rays with shorter wavelength
more penetrating dental x rays with longer wavelength
less penetrating dental x rays with shorter wavelength
less penetrating dental x rays with longer wavelength
interaction with the x ray photon as a result of the photoelectric effect is harmful to the patient because ionization occurs
the statement is true
the statement is false
the first part of the statement is false; second is true
the first part of the statement is true; second is false
statement is true
______ is a measurement of force that refers to the potential difference between two electrical charges:
voltage
ampere
wavelength
exposure time
voltage
which of the following statements is true of wavelength in reference to radiation?
mA controls the wavelength and energy of the x ray beam
x rays with shorter wavelength have less penetrating power
x rays with longer wavelength have less penetrating power
x rays with longer wavelength are less likely to be absorbed by matter
x rays with longer wavelength have less penetrating power
in dental radiography, the term _____ is used to describe the mean energy or penetrating ability of the x ray beam:
quantity
quality
intensity
wavelength
quality
which property of x rays allows for the image on the receptor?
effect on living tissue
penetrating power
fluorescence
focusing capability
penetrating power
which would you adjust if you wanted to produce characteristic radiation?
step-down transformer
kilovoltage
step-up transformer
mA
kilovoltage
which would you adjust if you wanted to create a larger electron cloud?
kilovoltage
mA
step-down transformer
step-up transformer
mA
the lead collimator:
restricts the size of the x ray beam
carries away the heat produced during the production of x rays
filters the longer-wavelength x rays from the beam
permits a small number of x rays to exit from the x ray tube
restricts the size of the x ray beam
which of the following statements is true of characteristic radiation?
the high speed electron passes close to the nucleus or hits the nucleus of the tungsten atom
it is the source of the majority of x rays that are produced
it only occurs at 70 kV and above
it is also known as braking radiation
it only occurs at 70 kV and above
which form of the x ray beam is most detrimental to the patient and operator?
scatter radiation
secondary radiation
useful beam
primary radiation
scatter radiation
which is the most common possibility when an x ray photon interacts with matter?
absorption or photoelectric effect
compton scatter
coherent scatter
no interaction
compton scatter
which of the following four possibilities that can occur when an x ray photon interacts with matter is responsible for producing densities on a dental receptor that make dental radiography possible?
absorption or photoelectric effect
compton scatter
coherent scatter
no interaction
no interaction
(1) X-ray photon production occurs as a result of both general and characteristic radiation. (2) General radiation accounts for a small number of x-ray photons produced because it takes high kV to dislodge the electrons from the K shell.
both statements are false
the first statement is false; second is true
the first statement is true; second is false
both are true
the first statement is true; second is false
which of the following components of the x ray machine would have two indicator lights?
x ray tubehead
extension arm
control panel
x ray tube
control panel
approximately what % of the kinetic energy of the electrons is converted to x rays at the anode?
100%
less than 1%
25%
50%
less than 1%
thermionic emission of electrons occurs at the:
tungsten filament in the cathode
copper stem
tungsten filament in the anode
molybdenum cup
tungsten filament in the cathode
in the dental x ray tube the number of electrons created is controlled by:
alternating current
direct current
kV
mA
mA
heat is a byproduct of x ray production. which component of the x ray tubehead dissipates the heat created by the production of x rays?
aluminum disks
metal housing
lead collimator
insulating oil
insulating oil
the purpose of the anode is to:
filter out nonpenetrating, longer-wavelength x rays
convert electrons into x ray photons
absorb heat created by the production of x rays
produce electrons when heated
convert electrons into x ray photons
within the x ray tube, electrons are generated by the:
tungsten filament in the anode
copper stem
tungsten filament in the cathode
molybdenum cup
tungsten filament in the cathode
which of the following statements is true of the wave concept of electromagnetic radiation?
frequency and wavelength are inversely related
velocity refers to the number of wavelengths that pass a given point in a certain amount of time
wavelength refers to the speed of the wave
frequency is defined as the distance between the crest of one wave and the crest of the next
frequency and wavelength are inversely related